5.7. SR 10-30-1995~~r ~~ ITEM 5.7. ~~ ity of ~~ MEMORANDUM l~ ~ TO: Mayor & City Council Rover FROM: Pat Klaers, City Administrator DATE: October 30, 1995 SUBJECT: Consider Mechanical Services Contract City administration, police, public works, and library staff have been discussing and reviewing the need for a maintenance contract and service agreement for the mechanical equipment in the new library and city hall. I have had the attached report from the building official in my office for a number of weeks while I continued to evaluate the need for this service and the associated costs of this contract. I am now convinced, as is the entire staff, that such a service agreement is appropriate and necessary for the long term maintenance of our city hall and library mechanical equipment. This is simply work that is too complex, technical, and time consuming to be left in the hands of non-professionals. The proposed contract that is attached to the building official's memo will be updated to reflect a November 1, 1995, beginning date. This expense is not in the 1996 budget. Depending on year end 1995 balances, we could encumber funds for this 1996 expense or we could use some of the government buildings reserve for this service in 1996. It is not planned to use 1996 Council Contingency funds for this expense. This service will be programmed into the 1997 budget. I recommend the City Council approve the mechanical services contract for the library and city hall with York International in the amount of $3,988 as recommended by the building official. 13065 Orono Parkway • P.O. Box 490 • Elk River, MN 55330 • (612) 441-7420 • Fax: (612) 441-7425 MEMORANDUM of ~~ TO: Pat Klaers, City Administrator .~ • River FROM: Cliff Skogstad, Building Official ` DATE: September 6, 1995 SUBJECT: Mechanical Service Contracts for Elk River Library & City Hall Since our conversation regarding mechanical services for the library and city hall, I have fine tuned the services needed and was able to submit my requirements to contractors to receive quotes for these services. These services will provide a twice a year service on changing out air filters, going through the systems regarding calibrations of thermostats, amperage of motors, greasing of motors, checking all fluids, testing of oils and compressors, checking for leaks, etc. A report will be given from the testing of the equipment to determine future breakdowns which will assist us in our budgeting process. Three companies were given the opportunity for pricing this service, they are York Heating and Air Conditioning, Johnson Control, and Palen Kimball. Two prices were given, one from Johnson Control in the amount of $5,744, and York International in the amount of $3,988. With these prices and time spent interviewing both companies, I am recommending that we use York International on a one year service contract. Provided for you with this memo is the one year service contract. If you need any additional information, I will try to assist. contract/bz 13065 Orono Parkway • P.O. Box 490 • Elk River, MN 55330 • (612) 441-7420 • Fax: (612) 441-7425 • Customer Name: City of Elk River Customer Address: P.O. BOX 490 13065 Orono Pkwy. Elk River MN 55330 . Equipment Address: City Hall Library York /nternationa/ Representative Name: Kirk Meintsma Title: Service Sales Representative Date: 08108\95 Agreement Number: • ANNUAL PREVENTIVE MAINTENANCE PROGRAM YORK will provide a complete program of preventive maintenance for the cooling and heating equipment listed in "Schedule A." To maintain the equipment in good working order, factory-trained technicians will perform all preventive maintenance tasks in accordance with the guidelines issued by YORK engineering or other manufacturers. This preventive maintenance program meets the manufacturer's requirements to properly maintain and service your equipment. All work will be performed during normal YORK working hours unless otherwise indicated in the supplemental service section of this Agreement. The annual preventive maintenance program includes a minimum of six operating inspections, plus annual shut- down preventive maintenance preparing the unit for the next season. Also, YORK will provide a written report of findings, corrective actions, and recommendations following each visit. Refrigerant Conservation Services -YORK Certified Technicians will perform additional leak detection activities and other services, including the use of storage and recycling equipment, in order to ensure compliance with the Clean Air Act and other state and local regulations on all items containing CFC and HCFC refrigerants .listed in "Schedule A." SUPPLEMENTAL SERVICES • Included Not Included A. Total Service Coverage -provides all repair labor and materials required to X keep the equipment listed in "Schedule A" in proper operating condition. This level of service offers the maximum protection against unpredictable repair expenditures, as well as ensures reliability and efficiency. B. Around-the-Clock Emergency Service, 7 Days/Week -YORK technicians will X respond, based on your selection below, to ensure proper and reliable operation of all items listed in "Schedule A." b 24 Hours/Day - 7 Days/Week (Including Holidays) b 8 Hours/Day - 5 Days/Week b Other C. Additional Inspections - in addition to the preventive maintenance program X described above, YORK will perform more P.M. inspections/year on the equipment covered by this Agreement. D. Guardian Service -provides 24 hour remote monitoring of YORK chillers. Both X anticipatory and shut-down alarms will be received and reviewed by qualified YORK personnel. Based on alarm conditions and customer requirements, YORK will respond in the most appropriate manner. YORK will also poll the chiller for status information twice each week. Reports summarizing alarms and polling information will be issued each month (available for YORK centrifugal chillers onlyl. • SERVICES NOT INCLUDED • IN THIS AGREEMENT If additional services are required, YORK will make specific recommendations, including tasks required, prices and timing. Upon customer agreement, work will be performed according to specifications in a timely manner. PRICING AND PAYMENT The annual price of this Agreement shall be $ 3,98A-On plus applicable taxes, and is payable- quartPrl ~_ upon receipt of the invoice. If the equipment is under a standard and/or extended warranty, the quaterly price shall be S 997-~~ until the warranty expires. TERM OF THIS AGREEMENT The initial term of this Agreement shall be 1 year(s) commencing on Sept_e!nhPr 1,1995 It shall then renew annually beginning on AitguGt 't1,1AGF which shall be the anniversary date of this Agreement. After the first 12 months, the price is subject to an annual escalation based on (1) cost changes in overhead and union-based rates; and (2) the wholesale price index for metal and metal products. • TERMS AND CONDITIONS This Agreement is subject to the terms and conditions on the back of this page. Customer Name: Address: Offered by York International, Representative Name: Date: Title: Accepted by Name: Title: _ Date: . Approved by YORK International Name: Title: Date: r1 LJ SCHEDULE A Fni iiannFNT Ilvr_i i ~n~n IN THIS AGREEMENT EQUIPMENT TYPE QTY. MANUFACTURER MODEL # SERIAL # RATING Reciprocating Chiller 1 York YCAZ77LE346P YLAM927507 185TR AHU-1 1 McOuay LSL-128DH 3XLO1368-04 AHU-2 1 McQuay LSL-108CH 3XLO1369-06 AHU-3 1 McOuay LSL-106CH 3XLO1370-06 AHU-4 1 McOua LSL-122DH 3XL01371-04 Chilled water pumps 2 UTE1 TE U.S. ELECTRIC 3HP Domestric Boiler 1 A.O.SMITH BT120M890 MM920249182 120K BTU Domestic Boiler 1 A.O.SMITH BT199880 MK920252457 199K BTU Hot Water Boiler 4 Slant Fin GG375EC 375K BTU Library Hot Water Boiler 3 Slant Fin 375KBTU Condensing Unit 1 Carrier 10TR Condensing Unit 2 Lennox 10TR Air Handling Units 2 Water Loop Pump Z Grundflo 1 /2 HP Customer Name: r•i~ff Gkngctad • ^ For the Cooling Season A. The Cooling Season Start-up Preparation and Inspection The Following task prepare your chiller for cooling duties with reliability, safety, and efficiency: 1. Checking auxiliary equipment operation 2. Checking refrigerant levels 3. Changing the oil as indicated by laboratory analysis 4. Checking the operation of crankcase heater, oil temperature, and tube system 5. Checking and testing all operating and safety controls 6. Checking for proper voltage and starter operation 7. starting the chilled and condenser water pumps where applicable 8. Starting the unit and calibrating controls and transducers • 9. Checking the proper settings for sub cooling and super heat 10. Logging operating conditions after the unit stabilizes 11. Review operating procedures with operator B. The Annual Equipment Shutdown Inspection and Preventive Maintenance The following tasks are performed once each year during a shutdown period in order to properly evaluate your equipment status and prepare your unit for the next cooling season: 1. Meging and recording motor winding resistance 2. Checking the oil level in the compressor; adding oil as required. 3. Checking refrigerant level of unit 4. Conducting a leak check and correcting any minor refrigerant leaks found 5. Check oil for acidity 6. Changing filter-dryer • 7. Checking crankcase heater for proper operation 8. Tightening the power wiring on contactors and in the motor terminal box • 9. Checking all relays, operating controls, and safeties 10. Checking and calibrating all controls, safeties, unloaders, and external interlocks 11. Checking the suction and discharge compressor valves 12. Furnish complete report to owner with any recommendations for repairs or unit upgrading options available • • AIR HANDLING UNITS A. Season Start-up Preparation and Inspection The following tasks prepare your equipment for cooling duty with reliability, safety and efficiency: 1. Verifying the integrity of all flexible duct connections to the unit 2. Checking amps and volts of the fan motor 3. Checking the operation of motor starters 4. Inspecting the cabinet for air/water leaks 5. Observing the integrity of insulation 6. Verifying damper operation 7. Inspect the coil area including coil fans 8. In heating applications, checking the operation of heating mechanisms and safety controls, including exhaust devices 9. Verifying the overall operation of the unit and discussing operating experience with customer personnel 10. Change pleated air filters B.. The Annual Equipment Shutdown and Inspection The f ollowing tasks are performed. once each year during a shutdown period in order to properly evaluate your equipment status and prepare your unit for the next season: 1 . Checking the spring isolators for proper tension 2. Verifying that flexible duct connections are intact 3. Checking fan motor amps and volts with fan running 4. Checking fan operation for excessive vibration 5. Cleaning starter contacts and checking for wear, burning, pitting, and .signs of overheating 6. Checking belts for wear, cracks and tension replace if necessary 7. Checking pulley grooves for smooth wear 8. Removing fan guards for cleaning and inspecting fan blades 9. Verifying grease line connections 10. Verifying. the tightness of motor mounts 11. Observing bearing movement and rotation and inspecting bearings for condition 12. Inspecting and lubricating fan and motor bearings 13. Checking drain pans and drain lines for dirt and sludge buildup • 14. Checking insulation 15. Inspecting, cleaning and replacing air filters 16. Checking the cleanliness of water or steam coils and cleaning (if applicable) 17. Checking the operation of drains 18. Winterizing water coils when required For Heating Applications: 19. Checking amperage and voltage of each electric heating stage 20. Checking tightness of connections and fuse condition 21. Checking gas-fired pilot and flame condition and operation 22. Checking the condition of gas valves, burners, and thermocouples 23. Checking the condition of the heat exchanger and the flue 24 Checking the inlet screens for cleanliness and blockage 25. Inspecting exhaust fan motor amps and volts 26. Inspecting exhaust fan belt tension 27 Checking humidifier sprays, grids and pans for scale buildup and plugging • • BOILERS 1.) Check all safeties 2.) Check gas valves 3.) Check general operation 4.) Check and adjust burners 5.) Check heat exchangers 6.) Clean if necessary • •