6.14. SR 05-17-2004Item# 6.14.
MEMORANDUM
TO:
FROM:
DATE:
SUBJECT:
Mayor and City Council
Scott Harlicker, Senior Planne
May 17, 2004
Case No. CU 04-08
Request by Olson General Contractors for a Conditional Use
Permit for Outdoor Storage
Request
Consider a request by Olson General Contractors for a conditional use permit for outdoor
storage.
Location
Lot 2, Block 1, Cascade Industrial Park; Jarvis Street and 169th Avenue alignment.
Zonin.q/Land Use
12 (Medium Industrial) / MI (Medium Industrial)
60 Day Rule
In order to comply with Minnesota Statute 15.99 (60 - Day Requirement), action must be
taken on this request by May 28, 2004
Attachments
· Location Map
· Memo from the City Engineer
· Development Plans
Memo to Mayor and City Council/CU 04-08
May 17, 2004
Page 2
Overview
The applicant is proposing to construct a 12,000 square foot building for a masonry
contractor business with accessory outdoor storage. The outdoor storage component of the
use requires a conditional use permit. The property is located on Jarvis Street, north of the
railroad tracks, in the Cascade Industrial Park. The property is currently undeveloped. The
lot to the south is a mini-storage facility; the property to the north is undeveloped; the
property to the west is a pipe yard, and single family residences are on the east side of Jarvis
Street in Ramsey. The surrounding properties, on the west side of Jarvis, have a land use
designation of MI (Medium Industrial).
Analysis
Site Plan
· Parking and Access
The site plan includes one driveway on Jarvis Street, located on the north side of the lot. A
23 space parking lot is proposed in front of the building. There is no specified parking
requirement in the zoning code for a contractor business. The applicant is providing parking
at a ratio of 1 space for every 520 square feet of floor area. For comparison, the parking
requirement for a warehouse is 1 space per 2000 square feet of floor area and for office it is
1 space for every 300 square feet. Parking should be sufficient for the proposed use. Access
to the outdoor storage is provided via a 24 foot wide driveway along the north side of the
building. The driveways and parking area will be paved with concrete curb and gutter.
· Outdoor Storage
The outdoor storage area will be located at the rear of the building. It will be about 155 feet
wide and 245 feet deep 08,000 sr.). It will have a Class V surface and will be setback 20 feet
from the south property line and 10 feet from the north property line. The drain field for the
septic system will be located between the storage area and the rear property line. The storage
area will be enclosed with a 6 foot high chain link fence. The storage area will be used to
store vehicles and masonry equipment. To reduce the possibility of incremental expansion of
the Class V, the edges of the storage area should be permanently defined with landscaping
ties.
The applicant is proposing to screen the storage area with a mix of pines, ash and maples. A
row of 6 pines is proposed along the north side of the storage area and a row of 6 pines is
proposed along the south side of the storage area. Five overstory trees are also proposed
along the north side of the storage area and four overstory trees are also proposed along the
south side. Because of the distance between the storage area and the rear property line, no
screening is proposed in that area.
· Grading, Drainage and Utilities
S:\PLANNING\Case Files\2004\CU 04-08 Olson General Contr\CU04-08CC5-17.doc
Memo to Mayor and City Council/CU 04-08
May 17, 2004
Page 3
Grading, drainage and utility issues are addressed in the City Engineer's memo
· Landscaping
The applicant is requesting a variance to the landscaping ordinance to plant fewer than the
required number of trees. The ordinance requires 44 trees with a mix of 50% (22) overstory,
25% (11) evergreens and 25% (11) ornamental. The applicant has submitted a landscape plan
that includes 43 trees, 20 over story, 11 ornamental and 12 evergreen. One additional
overstory should be added. The landscaped areas will include sod. The landscape ordinance
requires that all landscaped areas be irrigated. With the additional overstory tree, the
landscape complies with the landscape ordinance.
Signage
A freestanding sign is proposed along Jarvis Street. The sign will have to be setback 10 feet
from the property line and must comply with the sign requirements of the I2 zoning district.
A sign permit will be required. No wall signs are shown on the plans.
· Building Elevations
The building will be 12,000 square feet in size and will be used for office space, warehousing
and garage space. The exterior will be concrete tip-up panels with a ribbed finish. The front
entrance will be enhanced with a decorative metal canopy. The exterior finishes exceed the
requirements of the I2 district.
Planninq Commission Meefin.q
At the Planning Commission meeting held on April 27th, two neighbors spoke at the public
hearing. Because the area is zoned I2 and industrial uses surrounded this lot, the neighbors
did not see the need to plant all the trees required by the code. The Commission held a
lengthy discussion regarding the need for complying with the landscape ordinance. They felt
that the applicant could spread the required trees around the site or reduce the number of
trees and plant oversized trees.
Recommendafion
The Planning Commission and staff recommend that the City Council approve the
Conditional Use Permit for outdoor storage based on the following findings that the request:
(1)
Will not endanger, injure or detrimentally affect the use and enjoyment of other
property in the immediate vicinity or the public health, safety, morals, comfort,
convenience or general welfare of the neighborhood or the city.
(2) Will be consistent with the comprehensive plan.
&\PLANNING\Case Files\2004\CU 04-08 Olson General Contr\CU04-08CCS-17.doc
Memo to Mayor and City Council/CU 04-08
May 17, 2004
Page 4
(3) Will not impede the normal and orderly development and improvement of
surrounding vacant property.
Will be served adequately by and will not adversely affect essential public facilities and
services including streets, police and fire protection, drainage, refuse disposal, water
and sewer systems, parks and schools; and will not, in particular, create traffic
congestion or interference with traffic on adjacent and neighboring public
thoroughfares.
(5)
Will not involve uses, activities, processes, materials, equipment and conditions of
operation that will be detrimental to any persons or property because of excessive
traffic, noise, smoke, fumes, glare, odors, dust or vibrations.
(6) Will not result in the destruction, loss or damage of a natural, scenic or historic feature
of major importance.
(7)
Will fully comply with all other requirements of this Code; including any applicable
requirements and standards for the issuance of a license or permit to establish and
operate the proposed use in the city.
The conditional use permit is subject to the following conditions:
1. All comments of the City Engineer shall be addressed.
2. All signage shall comply with the sign ordinance and the freestanding sign shall be
setback 10 feet from the property lines.
3. All landscaped areas shall be irrigated.
4. The edges of the outdoor storage area shall be permanently defined with landscaping
ties.
5. One additional overstoty tree be planted.
S:\PLANNING\Case Files\2004\CU 04-08 Olson General Contr\CU04-08CC5-17.doc
' CA.GILL 170TH
164TH
162ND
156 x~ 15~TH
River
Case Number:.
Location Map
CU 04-08 OLSON GENERAL CONTRACTORS
N
owar-d R, Green Company
April 21, 2004
File: 823450J-0240
Mr. Scott Harlicker
Senior Planner
City of Elk River
13065 Orono Parkway
Elk River, MN 55330
RE: MAJESTIC MASONRY SITE PLAN
Dear Mr. Harlicker:
As requested, we have reviewed the submittal package for the proposed Majestic Masonry
Development in the Cascade Industrial Park. The site is proposed to be constructed on an
approximate three-acre site fronting on Jarvis Avenue. The site plan we reviewed was prepared by
Passe Engineering, Inc., and included storm drainage calculations. Based on our review, we
would offer the following comments:
The building is proposed to be 12,000 square feet with a bituminous parking area and
drive area, including concrete curb and gutter in the front and north side of the building.
The rear of the building is proposed to be a parking area approximately 1 65 feet long by
100 feet that will be gravel surfaced. Immediately beyond the gravel surface area is a
proposed swale, which will convey surface drainage from the rear of the building to the
regional ponding area. At the extreme rear of the lot is the proposed drain field area.
Given the size of this site, it will require an NPDES permit. General requirements of
that permit are that sediment and erosion protection needs to be in place before any
work begins on the site, and areas disturbed by grading and construction operations
need to have turf established within 14 to 21 days.
There is a minimal amount of silt fence shown along the rear of the grading operation
and slightly along the north property line. Given the grading and construction activities
in proximity to the property boundaries, silt fence will be required around the entire site
to protect from erosion onto adjacent properties until the parking areas and tuff are fully
established.
It is unclear what will protect the west edge of the gravel parking area from washing into
the swale and ultimately ending up in the regional pond. We would recommend that
there be some kind of barrier to not only keep the gravel in the parking area, but to
protect from vehicles parking and other materials being stored off of the gravel area and
encroaching into the swale.
Ltr~042104-Harlicker
2550 University Avenue West · Suite 400N · St. Paul, MN 55114 · 651/644-4389 fax 651/644-9446 toll free 888/368-4389
Mr. Scott Harlicker
April 21, 2004
Page Two
At the far west end of the property, a drain field area is shown approximately 140 feet
by 90 feet. We assume this is large enough for a primary and secondary site.
However, it is not noted as such on the plan.
The southeast corner of the building shows a holding tank for non-domestic waste. It is
unclear what this holding tank is for and how it will be dealt with. More information
should be provided relative to this non-domestic waste holding tank. In addition, the
well location is shown within approximately 25 feet of this tank. Is that sufficient setback
between the tank and the well site?
Based on our review of the drainage calculations, we have the following comments:
· Additional information needs to be provided concerning the existing conditions 2, 10,
and 100-year events, as well as the proposed conditions for the 2 and 10-year
events.
· The pond model does not match the regional pond information shown on the plan
sheet. On the plan sheet, the HWL is shown at 877.78 while in the model, the HWL
is shown as 874.58. This needs to be clarified.
· The subcatchment routing does not show any storm sewer pipe prior to entering the
pond, but there is storm sewer shown on the plan. This needs to be clarified in the
model.
· How will the rear parking area be made to drain directly west into the swale leading
to the regional pond and be prohibited from draining either to the south or north onto
the adjacent properties? More detail regarding this is needed on the plans.
If you have any questions regarding any of these comments, please call.
Sincerely,
Howard R. Green Company
Terry J. Maurer,
TJM:sw
Cc:
Mark Kretschmer, Passe Engineering, Inc.
1611 Highway 10 NE
Spring Lake Park, MN 55432
Ltr-042104-Harlicker
5ITE PLAN
N
E~IJILi~ING
Rosa
Architectural
Group
Inc.
1084 Sterling Street
St. Pad, Minnesota 55119
tel: 651-739-7988
fax; 651-739-3165
MAJESTIC MASONRY
ELK RIVER, MN
9201 52nd AVE. N.
NEW HOPE, MN 55428
763-535-1481
FILE
PROJECT NUMBER: 20404
DATE: MAR. 24, 2004
DRAWN BY: K. FAC'fOR
CHECKED BY: R. ROSA
REVISIONS:
SITE PLAN
A-1
REGIONAL POND
HY~L = 877. 7£
NWL = 874.00 i '-
.' .
~7~ ' ¢.' ~ :) ~ L ' "...' ".. .' ~ ~
- ~ ' .... ~ ..... ". ~ _ ~ ~ ~ I ' -- ~ ¢~ T~H~O~
............ , ,, ,, I ~ ( J
702.~1 1250GALPUMPTANK
EX
BfTU
~~x~F~
/
~ ~~ ~~~~ -Building:
~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ '- ' Front/Corner
MANHOLE AT 879.10
11 INCH = 30 FEET (~2' X ..~4' SHEET}
INCH = 60 FEET (11" x 17' SHEET)
CORE DRILL CONNECT TO
EXIS77NG 48" STORM
LOCATION MAP
PARKING LOT SECTION
GPA VEL CONSTRUCTION ENTRANCE
WITH BERM AND ~iLT FENCE
NOT TC SCALE
7'Y'PIC. AL INSTALLATION FOR SILT FENCE
..... ~ r:HEP. K D~ DETAIL
· 0~ rIEl/
glDE
P~ ~lE~'
ROSA ARCHITECTURAL GROUP
1084 STERLING STREET
ST PAUL. MINNESOTA 5511~
PHONE: (651} 739-7988
PASSE ENGINEERING, INC.
1611 HIGHWAY I0 N.E
SPRING LAKE PARK, MINNESOTA 55432
PHONE: (763) 780-4100 j
N
PLANT SC~E~ULE-L~NE)SC~PE PLAN
CO[::)E QLJ~,NTIT'T' L~TiN NAME C, OMMON N~,ME SiZE ROOT
S~ I~' ,~CER $AC~NA~IJM 'Q~,.~N MT.' $LJMMIT
550 5 MALtJ$, 5F~, 5F:'F~IN~ $NOLU Sf='~ING
JTL ~, S'f'F41N~ RETICIJLATA
ID 8, C. ORND5 5TOLONtFER,A 'IS.ANTI' 15ANTI
Th' 8, TAXI J5 × MEDIA 'T,&tJNTONII' T,ADNTON YELU 5 ~.,A.L. ,~OT
5~F iZ JUNIPERUS Ci41NENSI5 'SEA C=~EEN' SEA GREEN JLiNIPER 5 C=AL. POT
Rosa
Architectural
Group
Inc.
1084 Sterling Street
St. Paul, Minnesota 55119
tek 651-739-7988
fax: 651-739-3165
MAJESTIC MASONRY
ELK RIVER, MN
9201 52nd AVE. N.
NEW HOPE, MN 55428
763-535-1481
PROJECT NUMBER: 20404
DATE: MAR. 24, 2004
DRAWN BY: K. FACTOR
CHECKED BY: R. ROSA
REVISIONS:
FILE CGPY
LANDSCAPE PLAN
L-1
/
'1I II [ r
Q.=AST _~L-~V'AT/ON
Rosa
Architectural
Gcoup
Inc.
MAJESTIC MASONRY
ELEVATION
ELK RIVER, MN
9201 52nd AVE. N.
NEW HOPE, MN 55428
763-535-1481
(~ I],~,ST ELEY,47'I~:I~I
fill [' ~NDV
PROJECT NUMBER: 20404
DATE: MAR. 12, 2004-
DRAWN BY: K. FACTOR
CHECKED BY: R. ROSA
REVISIONS:
E~EVA TION~
A-3