Loading...
5.2 PCSR 05-24-1994 AGENDA ITEM 5.2 •tyof �lkRi• ver MEMORANDUM TO: PLANNING COMMISSION FROM: GARY SCHMITZ, PLANNING ASSIST. g(-1.. DATE: MAY 24, 1994 SUBJECT: CONDITIONAL USE PERMIT REQUEST BY GUARDIAN ANGLES CARE CENTER, PUBLIC HEARING, CASE NO. CU 94-20 REQUEST A conditional use permit request for a 22,704 square foot addition to the existing care center. S LOCATION Lot 1, Block 1, Guardian Angles Addition (400 Evans Avenue, Elk River, MN) ZONING/LAND USE PUD (Planned Unit Development)/ HR (High Density Residential) ATTACHMENTS Location Map, Zoning Map, Site Plan, Letter from Terry Maurer dated May 16, 1994 BACKGROUND Guardian Angles Care Center is requesting a conditional use permit for a 22,704 square foot addition to the existing care center. The proposed addition will be located on the east side of the existing care center. The following paragraphs will highlight the issues involved with this request. S P.O. Box 490 • 13065 Orono Parkway • Elk River, MN 55330 • (612) 441-7420 • Fax: (612) 441-7425 Guardian Angles Care Center Page 2 May 24, 1994 • BUILDING ADDITION The proposed expansion will be constructed with brick to match the existing care center. The basement of the expansion area will be used for storage purposes and for mechanical/electrical equipment. A training facility may be added to this area in the future. The first floor will consist of thirty-eight (38) double rooms, which can have two patients, and one single private room. The first floor expansion will also consist of an expanded dining area, community room, office space, and custodial area. PARKING AND DRIVES Guardian Angles is proposing to add forty-one (41) parking stalls along the north side of the parcel adjacent to the existing parking lot. There is also a small existing parking area on the south side of the care center. City code requires that nursing homes provide one parking space for every four residents/patients (based on the maximum capacity of the building), one space per employee on the major shift, plus one space per vehicle owned by the building management. Using this ratio, the care center will be required • to provide ninety (90) parking stalls. The care center will provide a total of one hundred, thirty-four (134) parking stalls. Therefore, parking should not become a problem with the proposed expansion. If parking does become a problem in the future, the care center does have ample room to add more parking stalls north of the existing and proposed parking lot. If this proposal is approved, a condition should be added requiring concrete curb and gutter be placed around the new forty-one (41) stall parking lot. This will ensure proper drainage of the site and protect the landscaped areas as well as provide an aesthetically pleasing appearance. GRADING AND DRAINAGE The site plan has been reviewed by City Engineer Terry Maurer. Attached is a letter from Terry Maurer outlining his comments. One issue raised by Mr. Maurer is that the building expansion area should be assessed a $600 per acre storm water impact fee. The expansion area involves approximately one acre of property, therefore, if this proposal is approved staff recommends a storm water impact fee of$600 be added as a condition of approval. • guardian.pc Guardian Angles Care Center Page 3 May 24, 1994 • LANDSCAPING/SCREENING Elk River City Code required one tree for every forty (40) linear feet of lot perimeter, therefore, sixty-four (64) trees are required on this parcel. The landscape plan shows a total of eighty-nine (89) existing trees on the parcel with an additional fifteen (15) trees being proposed with the expansion, for a total of one-hundred, four (104) trees. The landscape plan will exceed the minimum requirements of the City's landscape ordinance. After construction of the care center, all disturbed areas should be sodded or seeded as necessary to avoid erosion. Guardian Angles will be required to screen mechanical or roof-top equipment associated with the proposed expansion. EMERGENCY ACCESS The site plan shows a twelve (12) foot access road around the east side of the proposed expansion area. It is assumed that the access road is for emergency access for the existing care center. The proposed expansion will come very close to this road. At the Concept Review Meeting it was recommended that due to the close proximity of the expansion area and the fact that a doorway • is being proposed on the east end of the care center, the access road be paved with a bituminous surface and widened to a minimum width of twenty (20) feet. This will provide for easy access for emergency vehicles or other vehicles needing to access the easterly door. It should be added that this emergency access must be maintained and kept clear throughout the year. RECOMMENDATION Staff recommends approval of a conditional use permit by Guardian Angels Care Center for a 22, 704 square foot expansion to the existing care center with the following conditions: 1. CONCRETE CURB AND GUTTER BE REQUIRED AROUND THE NEW FORTY-ONE (41) STALL PARKING AREA. 2. A $600 STORM WATER IMPACT FEE BE PAID TO THE CITY PRIOR TO THE ISSUANCE OF A BUILDING PERMIT. 3. AFTER CONSTRUCTION, ANY DISTURBED AREAS MUST BE SODDED OR SEEDED AS NECESSARY TO PREVENT EROSION. • guardian.pc Guardian Angles Care Center Page 4 May 24, 1994 • 4. THE DETAILS OF TERRY MAURER'S MEMO DATED MAY 16, 1994, BE INCORPORATED INTO THE SITE PLAN. 5. THE ACCESS AROUND THE EAST SIDE OF THE PROPOSED ADDITION BE PAVED WITH A BITUMINOUS SURFACE A MINIMUM OF TWENTY (20) FEET WIDE. 6. THE EMERGENCY ACCESS MUST BE MAINTAINED AND KEPT CLEAR THROUGHOUT THE YEAR. • • guardian.pc • • .,... . . . .. . . .. . ".•. . � $ � • • ii...1: 111.1 .. ..,iiiii _-_ • . .. .. . • . ., 3 t <.a a.' ri I•.II.o ..• . • :133e11G K»£ tt .. B¢ B' O §p. •-•:•:•ii il.1'•,- r :;.'1..::.L ?: f '0 .4*,111 0`�.yams. l O l s /1 . :!; sit, —arm . I *.I'' '. t Jr ..1 0., -•'� 0`• .. .:.(1-4 i i"..i..Ln ...-.••••.:•,..:, .,-,.. ::<:•:.....,..;,..;./......,.:...":..-c,...:,....:...t:::2.,...:47.--,; ;.,.,.i,... ..,..-,::::,:.•:::c...... .... - - . . . : • • H •;tib• • \ L :w \ , . \ .:'.1 ,Ur 1 i n._ •' wa 1{Y.t1ND�r1 MIR N.+ ssr t I. • I ! t. .! l•T, I 1s r - Zs{ t 'ss 7 t I A.• a �.a S Ic -t- � • I + � • w �: %.r r .hIeLK'J ra",v�.�r I f t w'" -.52:—. '.•.. :•:',_:. t y it r K�K w .n 1 ra ++ • }7 at: r a '. ► � a cal �. iTricY T ' ac' • :;-1\ , r � • I ' ` {iI • I I 4r ` ' I ,-.;•:;,•:,-.;-• . C•T" O +� ) LrC)1 •yi I • k r•••1:::•'...,.....,,,',,.:•::,..1. 1 Apia 0 • Ip to e .D PROPOSED '''.:.1131s::4-, .,: nt,. EXPANSION + -•„', 5Tau.NEWe—may ® CO • Ve REMOEwST G �TY (iy REID • . O E. iGI 00o QQD O O ' • f .. '�i®® ®CID® / EXISTING t--eErsvicE out rtAW CARE CENTER�- Z Co' ®® ® O ilc® Ct. cam® ®® / ® .®® . g T 20D ac /� .1MD et, 0t° TY . :„„ * o 0 / * IV ODD T'' ; .Q O .c O.: ° O t O p ° ' O 0 O 0 tilt ay.. .. of �V Area, EVANS AVENUE - LANDSCAPE PLAN PLANT KEY. LEGEND KEY COMMON NAME LATIN NAME SIZE A SPRUCE,COLORADO BLUE PIICE41 EEGKI b'-@'HIGH CHERRY.AMUR BIRD4' Gill EXISTING PRUNUSP 0• MAPLE,RED SUNSET ACER REDRUM ' = 2-V,'CAL. `/ TREES D FRENCH LILAC SYRINGA VULGARIS CULTIVARS • 2 GALLON POT EXISTING _CONIFERS •ALL AREAS TO DE RODDED INCLUDING AREAS DAMAGED'DY CONSTRUCTION DOTH ,,' NUMDER OF CN AND OFF THE 8ITE - -4' , �Z PLANTS •REMOVE ALL TREES A6 REQUIRED FOR CONSTRUCTION. , Q KEY TO PLANT • CONSULTING ENGINEERS May 16, 1994 File: 230-229-11 Mr. Steve Ach City Planner City of Elk River am ENGINEERING 13065 Orono Parkway Elk River, MN 55330 ENVIRONMENTAL RE: GUARDIAN ANGELS CARE CENTER EXPANSION MUNICIPAL Dear Mr. Ach: PLANNING As requested, we have reviewed the information submitted by Guardian Angels regarding the proposed expansion of their Care Center located on the Evans Avenue campus. Based STRUCTURAL on our review, we have the following few comments: • SURVEYING 1. The plan shows an access road around the east side of the proposed expansion. We assume that this was for fire access to the existing building. As the building is TRAFFIC expanded much closer to this access road and in fact the expansion has a doorway on the east end, we would recommend that the access road be paved with a bituminous TRANSPORTATION surface a minimum of 20 feet wide. This will provide for easy access for emergency vehicles or other vehicles needing to access this easterly door. 2. Drainage from the site will be overland as with all the existing drainage. It should be noted that drainage will eventually make its way to the intersection of Main and Evans, and will continue to compound the existing problem at this location. As you are aware, City Council has reviewed preliminary plans for correcting this drainage problem and the improvements are tentatively scheduled for 1995. 3. Glenn Sundeen from the Municipal Utilities has indicated that electrical service to 1326 Energy Park Drive this site falls directly under the expansion area. The relocation of this electrical St.Paul,MN 55108 service needs to be coordinated with the Elk River Municipal Utilities. 612-644-4389 4. The area involved in the building expansion should be assessed the City's $600 per Fax:612-644-9446 acre stormwater impact fee. •9800ShelardParkway 5. Consideration should be given to whether or not the expansion area should be Minneapolis,MN 55441 assessed the trunk sanitary sewer and water fee. 612-546-0432 Fax:612-544-6398 • Mr. Steve Ach May 16, 1994 Page Two If you have any questions regarding any of these comments or would like further information, please call. Sincerely, MSA, CONSULTING ENGINEERS Terry J. Maurer, P.E. TJM:tw 230-1603.may • • ra = ON ME L OI �River �_ gc[�maiop��4 siuu�cc ��: -� Eic�wy �TBTM •I �� LOCATION MAP co CASE CU 94-20 ►� ardo P.O. Bax 490 • 12065 Orono Partway • Elk River, bIN 55330 • (612) 441-7420 y J Mkt. ,N