Loading...
5.2. BASR 08-27-2019Request for Action To Item Number Board of Adjustments 5.2 Agenda Section Meeting Date Prepared by Public Hearing August 27, 2019 Chris Leeseberg, Senior Planner Item Description Reviewed by Auto-Rec Bodyworks Inc., 21475 US Highway 169 Zack Carlton, Planning Manager Reviewed by  20’ Side Yard Setback, Case No. V 19-07 Action Requested Approve by motion, the 10’ side yard setback variance for the following reasons: 1. The general purpose and intent of the ordinance are met. 2. The property has a land use of residential and the use is consistent with the Comprehensive Plan. 3. The proposed use is reasonable and is permitted in the zoning ordinance. 4. The plight of the petitioner is due to circumstances unique to the property not a consequence of the petitioner’s own action or inaction. 5. The variance will not alter the essential character of the locality. and with the following condition: 1. The Conditional Use Permit (CU 19-14) shall be approved by the City Council and recorded prior to the variance being recorded. Background/Discussion The property is located at 21401 US Highway 169 and is zoned C-3, Highway Commercial with setbacks as follows: Front: 25 feet Side: 20 feet Rear: 40 feet The applicant is seeking a 10’ variance to construct an addition to their existing business located on the subject property. The applicant is also requesting an amendment (CU 19-14) to their existing Conditional Use Permit (CU 16-09). The property is bound by US Highway 169 on the west with a commercial concrete business across the highway, two properties the applicant owns to the south, and the ERX Motor Park (an off-road racing facility) to the east and north. The addition will be located west of the existing pole building and north of the “house” structure, connecting all structures together. The “house” structure will be utilized as office space. The Elk River Vision A welcoming community with revolutionary and spirited resourcefulness, exceptional service, and community engagement that encourages and inspires prosperity The property south of the “house” structure rises dramatically to the south, making it difficult to site the structure there without significant excavating. Applicable Regulation (The applicant’s responses are italicized with staff’s notes after.) Variances may be granted when the petitioner establishes that the variance satisfies all five of the criteria described below. The variance is: 1. Is in harmony with the general purpose and intent of the ordinance, and This new building will be impeding on the 20’ side yard setback on the north property line by 9.8’ leaving the building corner 10.2’ from the property line. Currently this space is used for a Class 5 road access for the neighbor to the north and the current residence. The general purpose and intent of the ordinance is to provide for the orderly development of land. Properties outside the Urban Service District (sewer and water) are larger and in turn have larger setbacks to help maintain larger distance between structures. The parcel to the north received a CUP for Active Use Storage in 2016, which has not been constructed and has since expired, but the proposed variance will not affect the orderly development. The request is in harmony with the general purpose and intent of the ordinance. 2. Is consistent with the City of Elk River Comprehensive Plan. The property is currently zoned commercial, and we would remain in that zoning. The Gravel Mining Area Land Use, Transportation, and Utility Plan guide the properties for Highway Business uses where commercial uses are allowed and encouraged. The proposed use is consistent with this plan. The request is consistent with the Comprehensive Plan. Variances may be granted when the petitioner establishes that there are practical difficulties in complying with the zoning ordinance. Practical difficulties means that: 3. The petitioner proposes to use the property in a reasonable manner not permitted by the zoning ordinance; Due to the grade and location of the existing house, the only buildable area on site is to the northwest of the existing building and house. With the demand needed for the commercial business, this would make the building impede on the 20’ property setback on the north property line. The property south of the “house” structure rises dramatically to the south, making it difficult to site a structure in that location without significant excavating. The applicant is proposing to build the structure on the site where there is minimal excavating impact while maintaining a reasonable setback from the Extreme Commercial Recreation-zoned parcel to the north. The petitioner proposes to use the property in a reasonable manner. 4. The plight of the petitioner is due to circumstances unique to the property not a consequence of the petitioner's own action or inaction; and Due to the slope of the land and existing house location, this leaves the only practical location to build. The applicant stated they need the amount of space proposed to operate on their commercial lot. With the dramatic elevation change on the property, the proposed location appears to be the soundest. The plight of the petitioner is due to circumstances unique to the property and is not a consequence of the petition's own action or inaction. 5. The variance, if granted, will not alter the essential character of the locality. If the variance is granted, this will not alter the locality but only improve it. With the new addition, the existing house will be refaced with versetta stone as well as many more alterations to the landscaping that will not only improve the property but help with road side appeal off of US169. The locale is comprised of industrial and off-road racing uses. The essential character of the locale will not be altered if the variance is granted. Financial Impact None Council Meeting If denied, or an appeal is made by any interested party by September 6, 2019, this item will go to the September 16, 2019, City Council meeting. Attachments  Location Map  Applicant’s Narrative  Letter of Support from ERX  Site Plans Auto Rec Body Works Zoning Narrative: This application is for Auto Rec Body Works, who will be adding a 48’ x 16 x 108’ extension to the existing building on site. Due to the amount of demand that Auto Rec Body Works is looking to expand their business in the community by adding additional Shop space as well as Renovating the existing Single-Family Home into Offices and Client Waiting Room. The new building plan is to be extend off the existing building face to the West 108’. With the Grade of the property and Single-Family Home that was existing on the property, the only usable location for this building extension is towards the North West. 1. This new building will be impeding on the 20’ side yard setback on the North Property line by 9.8’ leaving the building corner 10.2’ from the Property line. Currently this space is used for a Class 5 Road Access for the Neighbor to the North and the Current Residence. 2. The Property is currently Zoned Commercial, and we would remain in that Zoning. 3. Due to the Grade and location of the existing house, the only buildable area on site is to the Northwest of the existing building and house. With the demand needed for the Commercial business, this would make the building impede on the 20’ Property Setback on the North Property line. 4. Due to the Slope of the land and existing house location, this leaves the only practical location to build. 5. If the Variance is granted, this will not alter the locality but only Improve it. With the new addition, the existing house will be refaced with Versetta Stone as well as many more alterations to the landscaping that will not only improve the property but help with Road side appeal off of US 169. 16'8'SCALE:4'2'1'18"MB30"M30"M30"M30"M30"M30"M30"M30"M30"M30"M18"M18"M18"M18"M18"M18"M18"M30"M30"M30"M30"M30"M30"M30"M30"M30"M18"MB18"MB18"MB18"MB18"MB18"MBCOLUMN PLAN7'-10 1/2"0'-0"8'-0"7'-10 1/2"8'-0"15'-10 1/2"1'-6 3/4"23'-10 1/2"8'-0"31'-10 1/2"8'-0"39'-10 1/2"1'-1 1/4"47'-10 1/2"10'-0"51'-10 1/2"2'-0"61'-10 1/2"8'-0"63'-10 1/2"7'-10 1/2"71'-10 1/2" 79'-9" 7'-10 1/2"0'-0"4'-0"7'-10 1/2"12'-0"11'-10 1/2"8'-0"23'-10 1/2"3'-11 1/4"31'-10 1/2"7'-10 1/2"39'-10 1/2"47'-9"7'-10 1/2"79'-9"8'-0"7'-10 1/2"8'-0"15'-10 1/2"8'-0"23'-10 1/2"8'-0"31'-10 1/2"8'-0"39'-10 1/2"8'-0"47'-10 1/2"8'-0"55'-10 1/2"8'-0"63'-10 1/2"7'-10 1/2"71'-10 1/2" 0'-0" 4'-10 1/2"47'-9"16'-0"42'-10 1/2"3'-0"26'-10 1/2"3'-6"23'-10 1/2"14'-0"20'-4 1/2"6'-4 1/2"6'-4 1/2"0'-0"11111111111111234AS5BS5CS5CS5KS8FS630"M30"M30"M30"M2'-3 3/4"23'-7 1/2"2'-3 3/4"2'-2 1/4"25'-11 1/4" 28'-1 1/2"3'-10 1/2"28'-0"8'-0"24'-1 1/2"8'-0"16'-1 1/2"8'-1 1/2"8'-1 1/2"11DS618"M18"M7'-10 1/2"0'-0"8'-0"20'-0"8'-0"12'-0"4'-0"4'-0" 27'-10 1/2" 7'-7 1/2"15'-0"7'-4 1/2"7'-7 1/2"0'-0"18"M16"M16"M1'-0" VENTED SIDEWALLOVERHANGS2'-0" NON-VENTED ENDWALLOVERHANGS2'-0" VENTED SIDEWALLOVERHANGS30"MJS84'-0 3/4"35'-9 3/4"2'-10 3/4"48'-11 3/4"6'-5 1/4"25'-5 1/4"30"M30"M-GUTTER COVERS-ROOF LAP RIB SEALANT TAPE-ALL STEEL FASTENED WITH STAINLESS STEEL SCREWS-(3) 30x30 ATTIC ACCESS PANEL (VERIFY LOCATION)-16'-2"x14'-1" OVERHEAD DOOR-414'-2"x14'-1" OVERHEAD DOOR-312'-2"x14'-1" OVERHEAD DOOR-210'-2"x6'-1" OVERHEAD DOOR-1(11) 4429 MB SLIDING WINDOWS-1-1HEADERED TRUSS LOCATION-3-2x8 LAMINATED COLUMN LOCATION-3-2x6 LAMINATED COLUMN LOCATION-COLUMN PLAN LEGEND(5) 3068 MB910 9-LITE GLASS WITH CROSSBUCK WALKDOORS, INSWING, LEFT HINGE WITH LOCKSET-36"M-30"M-18"M16"M36" DIAMETER FOOTING WITH 4' TO BOTTOM OF 21" THICK CONCRETE PAD (2500PSI MINIMUM). 20" BELOW BOTTOM OF PRECAST CONCRETE COLUMN AROUNDEXPOSED REBAR CAGE AND 3/4"x14" THREADED ROD WITH AN ADDITIONALMINIMUM 1" ABOVE BOTTOM OF PRECAST CONCRETE COLUMN. PLACECONCRETE BELOW AND ABOVE BOTTOM OF LOWER COLUMN IN ONEOPERATION.30" DIAMETER FOOTING WITH 4' TO BOTTOM OF 21" THICK CONCRETE PAD (2500PSI MINIMUM). 20" BELOW BOTTOM OF PRECAST CONCRETE COLUMN AROUNDEXPOSED REBAR CAGE AND 3/4"x14" THREADED ROD WITH AN ADDITIONALMINIMUM 1" ABOVE BOTTOM OF PRECAST CONCRETE COLUMN. PLACECONCRETE BELOW AND ABOVE BOTTOM OF LOWER COLUMN IN ONEOPERATION.18" DIAMETER FOOTING WITH 4' TO BOTTOM OF 21" THICK CONCRETE PAD (2500PSI MINIMUM). 20" BELOW BOTTOM OF PRECAST CONCRETE COLUMN AROUNDEXPOSED REBAR CAGE AND 3/4"x14" THREADED ROD WITH AN ADDITIONALMINIMUM 1" ABOVE BOTTOM OF PRECAST CONCRETE COLUMN. PLACECONCRETE BELOW AND ABOVE BOTTOM OF LOWER COLUMN IN ONEOPERATION.16" DIAMETER FOOTING WITH 4' TO BOTTOM OF 21" THICK CONCRETE PAD (2500PSI MINIMUM). 20" BELOW BOTTOM OF PRECAST CONCRETE COLUMN AROUNDEXPOSED REBAR CAGE AND 3/4"x14" THREADED ROD WITH AN ADDITIONALMINIMUM 1" ABOVE BOTTOM OF PRECAST CONCRETE COLUMN. PLACECONCRETE BELOW AND ABOVE BOTTOM OF LOWER COLUMN IN ONEOPERATION.EXISTING COLUMN LOCATION--24"M24" DIAMETER FOOTING WITH 4' TO BOTTOM OF 21" THICK CONCRETE PAD (2500PSI MINIMUM). 20" BELOW BOTTOM OF PRECAST CONCRETE COLUMN AROUNDEXPOSED REBAR CAGE AND 3/4"x14" THREADED ROD WITH AN ADDITIONALMINIMUM 1" ABOVE BOTTOM OF PRECAST CONCRETE COLUMN. PLACECONCRETE BELOW AND ABOVE BOTTOM OF LOWER COLUMN IN ONEOPERATION.ROUGH OPENING SCHEDULEUNIT SYMBOLFROM LEGENDWIDTHHEIGHT37 3/4"81"52 1/4"33 5/8"11I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION, OR REPORTWAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION ANDTHAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDERTHE LAWS OF THE STATE OF MINNESOTA. _____________________________________________CORY MICHAEL BYRDDATE:________________ LICENSE NUMBER: 55608EXISTING15'x10'x50'BUILDINGEXISTING36'x14'x50'BUILDINGEXISTING23'x16'x52'BUILDINGEXISTING14'x9'x25'BUILDINGES6GS6HS7IS71CONNECTION WALL COLUMN LOCATION DIMENSIONSSIDEWALL COLUMNLOCATION DIMENSIONSSIDEWALL COLUMNLOCATION DIMENSIONSSIDEWALL COLUMNLOCATION DIMENSIONSENDWALL COLUMNLOCATION DIMENSIONS ENDWALL COLUMNLOCATION DIMENSIONS 1S31S51S31S3LS818" DIAMETER FOOTING WITH 20" THICK MINIMUM CONCRETE (2500 PSI MINIMUM)BELOW BOTTOM OF PRECAST CONCRETE COLUMN AROUND EXPOSED REBARCAGE AND 3/4"x14" THREADED ROD WITH ADDITIONAL READY-MIX BACKFILLEDTO 12" BELOW GRADE. PLACE CONCRETE BELOW AND ABOVE BOTTOM OFLOWER COLUMN IN ONE OPERATION.-18"MB2S61S3JOB NO.OFFICE:DRAWN BY:DATE:DATE:SCALE:SHEET NO.OFCHECKED BY:REVISED DATE:REVISED DATE:REVISED DATE:REVISED DATE:AS NOTEDMONTICELLO, MN059-089336RIC HAUGLAND ELK RIVER, MN RKS7/2/2019--------S1----------------NOTCHECK EDTARGET DATE:S9 16'8'SCALE:4'2'1' TRUSS/BRACING PLAN LEGEND 17128782888888881- 48’ 3090 R.C. TRUSS- 48' END RAFTER ASSEMBLY- 36' 4090 S.C. TRUSS- 1 1/2"x16" LVL RAFTER (2800 Fb)- 2x10 RAFTER (NO.1 SYP)- 10' GABLE PORCH FRAME- 2x4 TRUSS TIES- 2x6 DIAGONAL END BRACES (TO EXTEND TO FIRST TRUSS IN FROM ENDWALL)- 2x6 FLAT TRUSS TIE CENTERED IN BUILDING92789569911111113333444TRUSS/BRACING PLAN40'-0"8'-0"12'-0"8'-0"4'-0"4'-0"27'-10 1/2"98888885555557'-10 1/2"7'-10 1/2"8'-0"15'-10 1/2"8'-0"23'-10 1/2"8'-0"31'-10 1/2"8'-0"39'-10 1/2"8'-0"47'-10 1/2"8'-0"55'-10 1/2"8'-0"63'-10 1/2"8'-0"71'-10 1/2"7'-10 1/2"79'-9" 0'-0"8'-1 1/2"8'-1 1/2"8'-0"16'-1 1/2"8'-0"24'-1 1/2"3'-10 1/2"28'-0"7'-10 1/2"20'-0" 4'-10 1/2"I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION, OR REPORTWAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION ANDTHAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDERTHE LAWS OF THE STATE OF MINNESOTA. _____________________________________________CORY MICHAEL BYRDDATE:________________ LICENSE NUMBER: 55608EXISTING15'x10'x50'BUILDINGEXISTING36'x14'x50'BUILDINGEXISTING23'x16'x52'BUILDINGEXISTING14'x9'x25'BUILDING2S6JOB NO.OFFICE:DRAWN BY:DATE:DATE:SCALE:SHEET NO.OFCHECKED BY:REVISED DATE:REVISED DATE:REVISED DATE:REVISED DATE:AS NOTEDMONTICELLO, MN059-089336RIC HAUGLAND ELK RIVER, MN RKS7/2/2019--------S2----------------NOTCHECK EDTARGET DATE:S9 16'8'SCALE:4'2'1'DESIGN AND EXPLANATORY NOTES1.) EXTERIOR DOOR AND WINDOW LOCATIONS ARE TAKEN FROM THE EXTERIOR FACEOF THE NAILERS AND ARE TO THE CENTER OF THE DOOR AND WINDOW UNITS.VERIFY ALL DOOR AND WINDOW LOCATIONS WITH THE OWNER.I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION, OR REPORTWAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION ANDTHAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDERTHE LAWS OF THE STATE OF MINNESOTA. _____________________________________________CORY MICHAEL BYRDDATE:________________ LICENSE NUMBER: 55608124T#16 GABLE TRIMHI-RIB STEEL WAINSCOTT#167 TRANSITION TRIM18'-0"0'-0" 18'-0"25'-0"43'-0"43'-0"5'-0"48'-0"EAST ELEVATION124T#167 TRANSITION TRIMT#21 CORNER TRIMHI-RIB STEEL SIDINGT#170 BASE TRIMT#16 GABLE TRIM13'-0"0'-0"13'-0"21'-6"34'-6"10'-0"44'-6"44'-6"3'-6"48'-0"WEST ELEVATIONHI-RIB STEEL WAINSCOTT#167 TRANSITION TRIMT#21 CORNER TRIMHI-RIB STEEL SIDINGT#167 BASE TRIMVENT-A-RIDGE5" O.G. GUTTERS WITH GUTTER COVER5'-6"0'-0"5'-6"5'-6"8'-0"13'-6"13'-6"32'-6"46'-0"46'-0"11'-0"57'-0"10'-6"67'-6"67'-6"8'-0"75'-6"75'-6"4'-6"80'-0"SOUTH ELEVATION13'-0"0'-0" 13'-0"13'-0"8'-6"21'-6"21'-6"13'-6"35'-0"35'-0"16'-0"51'-0"51'-0"16'-0"67'-0"67'-0"10'-0"77'-0"77'-0"3'-0"80'-0"NORTH ELEVATION6'-6"21'-6"16'-0"5'-6"5'-6"28'-0"50'-0"78'-0"122.5 0'-0"6'-6"21'-6"16'-0"5'-6"5'-6"28'-0"50'-0"78'-0" 12'-3 5/8"VERSETTA STONE WAINSCOTJOB NO.OFFICE:DRAWN BY:DATE:DATE:SCALE:SHEET NO.OFCHECKED BY:REVISED DATE:REVISED DATE:REVISED DATE:REVISED DATE:AS NOTEDMONTICELLO, MN059-089336RIC HAUGLAND ELK RIVER, MN RKS7/2/2019--------S4----------------NOTCHECK EDTARGET DATE:S9 SIGNATURE:BUILDING DESIGN PHOTOSCALE: NOT TO SCALE1A2Page 2 0f 80.511.5MORTONBUILDINGSINC.113 THOMASPARK DRIVEMONTICELLO, MN55362this plan shallremain the propertyof morton buildings.any reproduction ofthis plan withoutwritten permissionfrom mortonbuildingis strictlyprohibited.unauthorized useshall entitle mortonbuildings to alldamages caused bysuch user includingpreparation charges,lost profits, damageto reputation, andany attorney fees.CONSTRUCTIONDRAWINGSdrawn by: John Rischmillerdate: 06 - 25 - 2019PROJECT #: B0592019223REVISIONS:21475 US - 169 ELK RIVER, MN 55303 AUTO REC BODY WORKS SIGNATURE:BUILDING DESIGN PHOTOSCALE: NOT TO SCALE1A3Page 3 0f 80.511.5MORTONBUILDINGSINC.113 THOMASPARK DRIVEMONTICELLO, MN55362this plan shallremain the propertyof morton buildings.any reproduction ofthis plan withoutwritten permissionfrom mortonbuildingis strictlyprohibited.unauthorized useshall entitle mortonbuildings to alldamages caused bysuch user includingpreparation charges,lost profits, damageto reputation, andany attorney fees.CONSTRUCTIONDRAWINGSdrawn by: John Rischmillerdate: 06 - 25 - 2019PROJECT #: B0592019223REVISIONS:21475 US - 169 ELK RIVER, MN 55303 AUTO REC BODY WORKS SIGNATURE:BUILDING DESIGN PHOTOSCALE: NOT TO SCALE1A5Page 5 0f 80.511.5MORTONBUILDINGSINC.113 THOMASPARK DRIVEMONTICELLO, MN55362this plan shallremain the propertyof morton buildings.any reproduction ofthis plan withoutwritten permissionfrom mortonbuildingis strictlyprohibited.unauthorized useshall entitle mortonbuildings to alldamages caused bysuch user includingpreparation charges,lost profits, damageto reputation, andany attorney fees.CONSTRUCTIONDRAWINGSdrawn by: John Rischmillerdate: 06 - 25 - 2019PROJECT #: B0592019223REVISIONS:21475 US - 169 ELK RIVER, MN 55303 AUTO REC BODY WORKS SIGNATURE:BUILDING DESIGN PHOTOSCALE: NOT TO SCALE1A6Page 6 0f 80.511.5MORTONBUILDINGSINC.113 THOMASPARK DRIVEMONTICELLO, MN55362this plan shallremain the propertyof morton buildings.any reproduction ofthis plan withoutwritten permissionfrom mortonbuildingis strictlyprohibited.unauthorized useshall entitle mortonbuildings to alldamages caused bysuch user includingpreparation charges,lost profits, damageto reputation, andany attorney fees.CONSTRUCTIONDRAWINGSdrawn by: John Rischmillerdate: 06 - 25 - 2019PROJECT #: B0592019223REVISIONS:21475 US - 169 ELK RIVER, MN 55303 AUTO REC BODY WORKS