Loading...
MISKE7_21_2FILLMORE DRIVE NW 0+00.00 TO 8+50.00 910 920 930 940 950 960 970 910 920 930 940 950 960 970 0+50956.9951.341+00957.9950.311+50958.0949.272+00957.8948.242+50955.5947.203+00951.7946.163+50949.5945.134+00948.2944.094+50947.8943.055+00949.0942.025+50948.0940.986+00947.4939.946+50946.3938.917+00944.5937.877+50941.2936.848+00937.0935.80167 LF - 8 "PVC SDR 3 5 @ 4 . 2 8 % 61 RE=938.9 IE=927.0 NE IE=926.9 S BUILD=12.0' 199 LF - 8" PVC SDR 35 @ 2.03% 62 RE=943.1 IE=931.2 NE IE=931.0 SW BUILD=12.0' 180 LF - 8"PVC SDR 35 @ 2.03% 63 RE=946.8 IE=934.9 NE IE=934.8 SW BUILD=12.0' 79 LF - 8"PVC SDR 35 @ 1.95% 64 RE=948.4 IE=936.5 N IE=936.4 SW BUILD=12.0' 100 LF - 8" PVC SDR 35 @ 1.99% 65 RE=950.5 IE=938.5 S BUILD=12.0' 11.3° BEND 22.5° BEND 22.5° BEND 11.3° BEND 8" X 6" TEE 8" X 8" TEE 22.5° BEND HYD 6"GV 10 LF 6" DIP CL 52 HBOE: 942.8 SMH 46 RE=935.6 IE=919.0 E IE=918.9 N IE=918.8 W BUILD=16.8' 20 LF - 8" PVC @ 4.2 7 % CONNECT TO EXISTING 8" SANITARY STUB ELEV =919.76 (FIELD VERIFY) PROPOSED EXISTING 7.5' MIN COVERPROP. STM XING IE-937.0 START UTILITY CONSTRUCTIONCONNECT TO EXISTING 8" WATERMAIN ELEV=942.53 (FIELD VERIFY) 8" GATE VALVE INSULATE WATERMAIN LOWER & INSULATE WATERMAIN STM XING IE-932.2 (VERIFY) PROVIDE 18" MIN. SEPERATION 950.40 938.48 11.9'948.27 936.40 936.40 11.9' 946.65 935.17 935.17 11.5'942.95 930.83 930.83 12.1'938.82 926.51 926.51 12.3' 935.51 16.7'100 2.08% 79 1.56% 2.41% 2.18% 4.07% 180 198 167 919.71 4.07OUTOUTBOTBOTHWLHWLINFILTRATIONBASIN 10BTM: 926.5 (5,300 SF)OUT:927.0HWL:928.8EOF:929.0189TH AVENUE NW259+00260+00261+00262+00263+00264+00WBP8+38.05 0+00 1+00 2+00 3+ 0 0 4+ 0 0 5+0 0 6+00 7+00 8+00 952.4 950.3 948.2 94 6 . 2 94 4 . 1 942 . 0 939.9 937.9 935.8 951.3 949.3 947. 2 9 4 5 . 1 94 3 . 1 941. 0 938.9 936.8 FILLMORE 931.36LP939 .0936.49933.99931.7931.7933.2937.74935.24932.7931.4932.5952.40 HP 94 6 . 4 3 LP6+007+008+009+0010+001 1 + 0 0951.0952.4951.4949.7948.0 9 4 6 . 5951.7952.2950.6948.994 7 . 2 WBPWBPWBPWBPWBPWBPWBPWBP189THAVENW189THAVEDRIVE FILLMORE DRIVE TWINPARKWAY941.8941.5EOF939.5#320#321#322#323#324#325#326#459#460#461#462#463#410#409#408#407#406#405#404#403#402#401#400#411#412#316#317#318#319#342#357#358#359#360#361#362#363#3641.9%1.8%931.96 SAN SERV 933.67SAN SERV 934.36SAN SERV 932.98 SAN SERV 2000 2001 2000 0+00 1+00 2+00 3+ 0 0 4+ 0 0 5+0 0 6+00 7+00 8+00 8+38.05 45 46 48 47 1801A 1801B 2000C-2 2000C 2000B 2000B-2 2000A-2 2000A 65 64 63 62 61 8" DIP CL 52 8" PVC SDR 358" D I P C L 5 2 8" P V C S D R 3 5 8" DIP CL 52 CBOX:937.6 CBOX:938.9 CBOX:940.1 CBOX: 941.4 CBOX:942.8 CBOX:944.2 CBOX:945.5 CBOX:947.3 CBOX:949.9CBOX:951.8 CBOX: 951.6 CBOX: 950.4 CBOX: 949.0 CBOX:947.9 CBOX:946.8 CBOX:945.5 CBOX:943.9 CBOX:942.0 CBOX: 940.4 CBOX: 934.3 CBOX: 932.9 CBOX: 932.7 SERV:0+66 925.6SERV:1+31926.9 SERV:0+06 928.0 SERV:0+61929.4 SERV:1+28 930.7 SERV:1+93932.1 SERV:0+62933.4 SERV: 1+47936.0 SERV: 0+19938.1 SERV:0+96939.7 SERV:0+93939.5 SERV:0+37 938.3 SERV:0+62 937.0 SERV:0+05935.9 SERV:1+37 934.8 SERV:0+72 933.0 SERV:1+87931.9 SERV:1+08 930.1 SERV:0+21928.8 8" P V C S D R 3 5 8'x8'x4"INSULATION(TYP.)8'x8'x4"INSULATION(TYP.)TNH=945.82 38'64' 48' 33' 27' 68'40'41' 24' 52' 31'56' 25' 39' 35' 38' 43' 43' 44' 88' 19'42' 40'25' 40'58' 43' 22' 36' 42' 60' 21' 43' 35' 56' 29' 49' 43' 61' 36' Sep 27, 2021 - 12:31pm - User:tkeeley L:\PROJECTS\20460.70\CAD\Record Plans\Miske Meadows 7th Addition Record Plan Sheets\20460.70-RP-C6-UTILITY.dwg C6.03 UTILITY PLAN - FILLMORE DRIVE THE SUBSURFACE UTILITY INFORMATION SHOWN ON THESE PLANS IS A UTILITY QUALITY LEVEL D. THIS QUALITY LEVEL WAS DETERMINED ACCORDING TO THE GUIDELINES OF ASCE/CI 38-02, TITLED "STANDARD GUIDELINES FOR THE COLLECTION AND DEPICTION OF EXISTING SUBSURFACE UTILITY DATA." THE CONTRACTOR AND/OR SUBCONTRACTORS SHALL DETERMINE THE EXACT LOCATION OF ALL EXISTING UTILITIES BEFORE COMMENCING WORK, BY CONTACTING THE NOTIFICATION CENTER (GOPHER STATE ONE FOR MINNESOTA). THE CONTRACTOR AND/OR SUBCONTRACTOR AGREE TO BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES, WHICH MIGHT BE OCCASIONED BY HIS OR HER FAILURE TO EXACTLY LOCATE AND PRESERVE ANY AND ALL UTILITIES (UNDERGROUND AND OVERHEAD). IF THE CONTRACTOR ENCOUNTERS ANY DRAIN TILE WITHIN THE SITE, HE OR SHE SHALL NOTIFY THE ENGINEER WITH THE LOCATION, SIZE, INVERT AND IF THE TILE LINE IS ACTIVE. NO DRAIN TILE SHALL BE BACKFILLED WITHOUT APPROVAL FROM THE PROJECT ENGINEER. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES WHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THE PLANS. SCALE HORIZONTAL: 1"=50' VERTICAL: 1"=10' SCALE IN FEET 0 10050 NORTH LEGEND EASEMENT WATERMAIN SANITARY SEWER EXISTINGPROPOSED STORM SEWER CURB & GUTTER D S S SANITARY SERVICE WATER SERVICE PROPERTY LINE D S S FUTURE 8'x8'x4" INSULATION PLANK Project Location Date Submittal / RevisionNo. Certification Sheet Title Summary Revision History Sheet No.Revision Project No. By Designed:Drawn: Approved:Initial Issue: Phase: Client PAXMAR, LLC. 2850 CUTTERS GROVE AVE SUITE 207 ANOKA, MN 55303 MISKE MEADOWS SEVENTH ADDITION ELK RIVER, MN ETL CJS ETL CONSTRUCTION 04/26/2021 A 20460.70 I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly licensed professional ENGINEER under the laws of the state of Minnesota. If applicable, contact us for a wet signed copy of this plan which is available upon request at Sambatek's, Minnetonka, MN office. Registration No.Date:04/26/202150475 Eric T. Luth A 05/17/21 JB REVISE STORM THESE RECORD PLANS HAVE BEEN PREPARED, IN PART, BASED ON INFORMATION COMPILED AND FURNISHED BY OTHERS. THE ENGINEER HAS NOT VERIFIED THE ACCURACY AND/OR COMPLETENESS OF THE INFORMATION PROVIDED AND SHALL NOT BE RESPONSIBLE FOR ANY ERRORS OR OMISSIONS WHICH HAVE BEEN INCORPORATED INTO THESE RECORD PLANS AS A RESULT. SAMBATEK, INC. 09/27/21 C.W. HOULE INC. C.W. HOULE INC. COMPLETED BY: DATE OF COMPLETION: STREET/UTILITY CONTRACTOR: GRADING CONTRACTOR: RECORD PLAN NOTES