Loading...
MISKE7_21_3188TH AVENUE NW -1+00.00 TO 9+00.00 900 910 920 930 940 950 960 970 900 910 920 930 940 950 960 970 -0+50 0+00927.9927.930+50928.5928.341+00929.9929.341+50931.9930.772+00933.9932.902+50935.9935.723+00937.9938.963+50941.9942.214+00953.9945.464+50959.7948.215+00962.8950.125+50963.0951.206+00961.7951.456+50956.3950.867+00949.2949.787+50944.6948.698+00937.0947.958+50929.8947.2168 RE=951.4 IE=939.4 NW BUILD=12.0' 198 LF - 8" PVC SDR 35 @ 2 . 9 8 % 67 RE=945.5 IE=933.6 SE IE=933.5 NW BUILD=12.0' 270 LF - 8 " PVC SDR 3 5 @ 5 . 7 0 % 66 RE=930.1 IE=918.1 SE IE=918.0 W BUILD=12.0' 128 LF - 8" PVC SDR 35 @ 1.79% 8" DIP CL 5 2 8" DIP CL 52 11.3° BEND 8" X 8" TEE 8" X 6" TEE 8" X 6" TEE 11.3° BEND 22.5° BEND11.3° BEND HYD 6"GV 10 LF 6" DIP CL 52 HBOE: 945.9 CONNECT TO EXISTING 8" WATERMAIN ELEV=920.43 (FIELD VERIFY) FUTURE EXISTING7.5' MIN COVERHYD 6"GV 8 LF 6" DIP CL 52 HBOE: 951.7 HYD 6"GV 8 LF 6" DIP CL 52 HBOE: 947.4 8" X 6" TEE 8" DIP CL 52END UTILITY CONSTRUCTIONPROP. STM XING IE-935.0 8" SAN XING IE-916.5 EX SMH 10 RE=927.9 IE=907.4 N IE=907.4 S BUILD=20.6' BULKHEAD AND ABANDON EXISTING SANITARY SEWER STUB PER CITY SPECIFICATIONS PROP. STM XING IE-923.5 CORE DRILL AND CONNECT TO EX. MH @ IE=915.69 INSTALL 8.3' INTRAFLOW INSIDE DROP TO 907.40 (FIELD VERIFY) 11.3° BEND 8" GATE VALVE 8" GATE VALVE INSULATE WATERMAIN 927.86 907.35 907.35 20.5' 929.94 917.82 917.82 12.1' 945.22 925.67 925.67 19.6' 951.26 939.26 12.0' 197 6.90% 269 129 2.92% COULD NOT FIELD VERIFY IE ELEV.1.65 INFILT R ATI O N BASIN 9 BTM:9 22 ( 20,8 0 0 SF) OUT: 9 2 4. 0 HWL: 92 5. 4 EOF: 9 2 8. 5 253+00254+00255+00256+00257+00258+00951.47 HP927.5 1 LP0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 927.9 929.3 932.9 939.0 945.5 950.1 951. 4 949.8 947.9 928.3 930.8 935.7 942.2 948.2 951.2 950.9 948.7 947.2 928.96 HP927. 3 2 L P 927. 3 2 L P 7+ 0 0 8 + 0 0 9 + 00 10 + 0 011+ 0012+009 2 9 . 0 9 2 8 . 5 9 2 8 . 0 9 2 7 . 5927 .7930.59 2 8 .8 9 2 8 . 8 9 2 8 . 2 9 27 .8 9 2 7 . 3928.8 IVANHO E DR IV E 948.09 HP 944.7946.7948.1946.5944.0941.5945.7947.7947.6945.2942.7188TH WBP WBP WBP WBP WBP AVE NW 188T H AVE NW GRANTTWIN TWINLAKESPARKWAYEOF 927.9 #468 #469 #499#275 #466 #467 #465#464 #296#297#298#299#254 #256 #257 #258 #259#255 #266#267#268#269#270#271 #272 #273 #274#300#301 #302 #303 #304 945.23SAN SERV 947.77 SAN SERV 947.51 SAN SERV 945.65 SAN SERV 943.85 SAN SERV 944.10SAN SERV 0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 43 42 44 2301 2000D 2000E 2303 2302 2300 68 67 66 1601 1605 1602 1603 1604 2203 8" PVC SDR 35 8" DIP CL 52 8" PVC SDR 35CBOX: 929.8 CBOX:930.9 CBOX:932.8 CBOX:936.5 CBOX:941.5 CBOX:945.1 CBOX:948.3 CBOX:950.9 CBOX: 952.1 CBOX:951.1 CBOX: 947.6CBOX:942.6 CBOX: 938.0 CBOX:947.2 CBOX:945.4 CBOX:944.4 CBOX:951.9 SERV:1+73939.8 SERV:1+00939.0 SERV:0+18 937.4SERV:2+00930.4 SERV:1+33925.9 SERV:0+60917.7 SERV:1+22919.1 SERV:0+35 920.7 SERV:1+00924.3 SERV:1+91929.2 SERV:2+30 932.9 SERV:0+15938.3 SERV:0+76 938.5 SERV:1+39 940.1 8" DIP CL 52 8'x8'x4" INSULATION (TYP.) EX SMH-10 1607 TOP OFWATERMAIN= 939.3 32' 74' TNH=954.18 TNH=948.68 74'22' 40' 23' 43' 27'45'26'16'36'68'24'39' 59' 44' 53'81' 36' 47'40' 40'22' 39' 42' 39' 33' 48' 55' 39' 32' TNH=950.72 Oct 12, 2021 - 11:21am - User:tkeeley L:\PROJECTS\20460.70\CAD\Record Plans\Miske Meadows 7th Addition Record Plan Sheets\20460.70-RP-C6-UTILITY.dwg C6.04 UTILITY PLAN - 188TH AVENUE THE SUBSURFACE UTILITY INFORMATION SHOWN ON THESE PLANS IS A UTILITY QUALITY LEVEL D. THIS QUALITY LEVEL WAS DETERMINED ACCORDING TO THE GUIDELINES OF ASCE/CI 38-02, TITLED "STANDARD GUIDELINES FOR THE COLLECTION AND DEPICTION OF EXISTING SUBSURFACE UTILITY DATA." THE CONTRACTOR AND/OR SUBCONTRACTORS SHALL DETERMINE THE EXACT LOCATION OF ALL EXISTING UTILITIES BEFORE COMMENCING WORK, BY CONTACTING THE NOTIFICATION CENTER (GOPHER STATE ONE FOR MINNESOTA). THE CONTRACTOR AND/OR SUBCONTRACTOR AGREE TO BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES, WHICH MIGHT BE OCCASIONED BY HIS OR HER FAILURE TO EXACTLY LOCATE AND PRESERVE ANY AND ALL UTILITIES (UNDERGROUND AND OVERHEAD). IF THE CONTRACTOR ENCOUNTERS ANY DRAIN TILE WITHIN THE SITE, HE OR SHE SHALL NOTIFY THE ENGINEER WITH THE LOCATION, SIZE, INVERT AND IF THE TILE LINE IS ACTIVE. NO DRAIN TILE SHALL BE BACKFILLED WITHOUT APPROVAL FROM THE PROJECT ENGINEER. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES WHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THE PLANS. SCALE HORIZONTAL: 1"=50' VERTICAL: 1"=10' SCALE IN FEET 0 10050 NORTH LEGEND EASEMENT WATERMAIN SANITARY SEWER EXISTINGPROPOSED STORM SEWER CURB & GUTTER D S S SANITARY SERVICE WATER SERVICE PROPERTY LINE D S S FUTURE 8'x8'x4" INSULATION PLANK Project Location Date Submittal / RevisionNo. Certification Sheet Title Summary Revision History Sheet No.Revision Project No. By Designed:Drawn: Approved:Initial Issue: Phase: Client PAXMAR, LLC. 2850 CUTTERS GROVE AVE SUITE 207 ANOKA, MN 55303 MISKE MEADOWS SEVENTH ADDITION ELK RIVER, MN ETL CJS ETL CONSTRUCTION 04/26/2021 A 20460.70 I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly licensed professional ENGINEER under the laws of the state of Minnesota. If applicable, contact us for a wet signed copy of this plan which is available upon request at Sambatek's, Minnetonka, MN office. Registration No.Date:04/26/202150475 Eric T. Luth A 05/17/21 JB REVISE STORM THESE RECORD PLANS HAVE BEEN PREPARED, IN PART, BASED ON INFORMATION COMPILED AND FURNISHED BY OTHERS. THE ENGINEER HAS NOT VERIFIED THE ACCURACY AND/OR COMPLETENESS OF THE INFORMATION PROVIDED AND SHALL NOT BE RESPONSIBLE FOR ANY ERRORS OR OMISSIONS WHICH HAVE BEEN INCORPORATED INTO THESE RECORD PLANS AS A RESULT. SAMBATEK, INC. 09/27/21 C.W. HOULE INC. C.W. HOULE INC. COMPLETED BY: DATE OF COMPLETION: STREET/UTILITY CONTRACTOR: GRADING CONTRACTOR: RECORD PLAN NOTES