Loading...
MISKE7_21_42003 2004 2002 2001 2000 2000D 2000E 2000C-2 2000C 2000B 2000B-2 2000A-2 2000A 61 2000C3 2801 2800 1800 1900 1901 2000C-2 2000C3 2000B-2 2000A-2 255+ 0 0 256+0 0 257+ 0 0 258+00 259+00 260+00 261+ 0 0 26 2 + 0 0 26 3 + 0 0 264 + 0 0 265+00 266+006+007+008 + 00 9+00949.894 7 .9945.7950.9 94 8 . 7 947 .2943.58+38.057+008+00937.9935.8938.9936.8948.09 HP 9 3 1 . 3 6 LP948.1 946.5 944.0 941.5 939.0 936.49 933.9 9 93 1 . 7 9 3 1 . 7 933 . 2 934.7 936.2 947.7 947.6 945.2 942.7 940.2 937.74 935.24 932 . 7 9 3 1 . 4 93 2 . 5 934. 0 935.5 937.0FILLMOREDRIVE188THAVENWGRANTCOURTTW I N LAKE S PARKWAY TWIN LAKES PARKWAY PARKW A Y EOF 931.6EOF931.6EOF 929. 0 EO F 93 6 . 5 #463 #410 #409 #408 #407 #411 #412 #413 #414 #442 #499 #465 #464 #296 #297 #504 #505 #506 1 12+0012+18.14???935.2935.4EX. FE S 1 9 0 0 IE=925 . 1 9 EX. FE S 1 9 0 1 IE=922 . 0 6 OUTL O T C OUT OUT BOT BOTHWL HWL INFILT R A T I O N BASIN 1 1 BTM: 9 2 5 . 0 ( 8 , 5 0 0 S F ) INFILT R A T I O N BASIN 1 0 BTM: 9 2 6 . 5 ( 5 , 3 0 0 S F ) OUT: 927.0HWL: 928.8EOF: 929.0 1 1 STORM 2000E - 2100 910 920 930 940 950 960 910 920 930 940 950 960 STORM 2000A - 2000A2-21 910 920 930 940 950 910 920 930 940 950 STORM FES 2000C-3 TO 2000C 915 920 930 940 950 960 915 920 930 940 950 960STORM 2000B2 - 2000B-22 910 920 930 940 950 910 920 930 940 950 175 LF - 15" RCP @ 2.80%CBMH 2000D (48")RE=941.78BLD=4.6'IE=937.67 NWIE=937.18 NECBMH 2000C (48")RE=937.22BLD=5.0'IE=932.20 NIE=932.30 SWIE=932.20 E122 LF - 15" RCP @ 2.21%CBMH 2000B (48")RE=934.01BLD=4.5'IE=929.69 NIE=929.50 WIE=929.53 E159 LF - 18" RCP @ 1.65%CBMH 2000A (60")RE=931.06BLD=4.3'IE=926.90 WIE=926.80 NEIE=926.76 SE94 LF - 24" RCP @ 0.50%CB 2000E (24"X36")RE=941.88BLD=4.0'IE=937.90 SECBMH 2001 (60")RE=932.17BLD=9.4'IE=927.14 EIE=926.25 NWIE=926.28 SCBMH 2000A (60")RE=931.06BLD=4.3'IE=926.90 WIE=926.80 NEIE=926.76 SE31 LF - 15" RCP @ 0.96%CB 2000A-2 (24"X36")RE=931.05BLD=4.0'IE=927.10 SWCBMH 2000B (48")RE=934.01BLD=4.5'IE=929.69 NIE=929.50 WIE=929.53 ECB 2000B-2 (24"X36")RE=933.94BLD=4.0'IE=929.97 S31 LF - 15" RCP @ 0.90%CBMH 2000C (48")RE=937.22BLD=5.0'IE=932.20 NIE=932.30 SWIE=932.20 E31 LF - 15" RCP @ 1.01%CBMH 2000C-2 (48")RE=937.24BLD=4.7'IE=932.51 NWIE=932.51 SCONNECT TO EXISTING 24" STORM SEWER STUB IE=926.07 (FIELD VERIFY) 8" SAN XING IE=920.0 8" SAN XING IE=919.2 8" WM XING 8" SAN XING IE=918.5 8" WM XING 2000A 2000A-2 2000B 2000B-2 2000C 2000C-2 2000D 2000E CBMH CB CBMH CB CBMH CBMH CBMH CB Structure Table STR. #TYPE CASTING 8" SAN XING IE=917.6 8" WM XING R-3067-VBI R-3067-VBI R-3067-V R-3067-V R-3067-V R-3067-V R-3067-V R-3067-V 33 LF - 15" RCP @ 1.00% 38 LF - 15" RCP @ 0.50% FES 2000C3 15" IE=932.70 8" WM XING CBMH 2000C (48")RE=937.22BLD=5.0'IE=932.20 NIE=932.30 SWIE=932.20 E941.76937.614.2'941.73936.93936.934.8'2.06%937.07931.765.3'931.76931.762.95%931.94926.648.8'925.89925.94930.85926.604.3'926.60926.60933.90929.304.6'929.30929.301.70% 2.02% 0.64%930.95926.884.1'930.85926.604.3'926.60926.600.85% 2.24%933.90929.304.6'929.30929.30933.94930.043.9'937.07931.765.3'931.76931.76937.02932.274.8'932.271.55% 0.73% 932.56 121 160 95 33 175 33 33 40 33 925.99 SCALE IN FEET 0 10050 NORTH Sep 27, 2021 - 12:50pm - User:tkeeley L:\PROJECTS\20460.70\CAD\Record Plans\Miske Meadows 7th Addition Record Plan Sheets\20460.70-RP-C7-STORM.dwg C7.01 STORM SEWER PLAN (2000) LEGEND EASEMENT WATERMAIN SANITARY SEWER EXISTINGPROPOSED STORM SEWER CURB & GUTTER D S S SANITARY SERVICE WATER SERVICE PROPERTY LINE D S S FUTURE SCALE HORIZONTAL: 1"=50' VERTICAL: 1"=10' THE SUBSURFACE UTILITY INFORMATION SHOWN ON THESE PLANS IS A UTILITY QUALITY LEVEL D. THIS QUALITY LEVEL WAS DETERMINED ACCORDING TO THE GUIDELINES OF ASCE/CI 38-02, TITLED "STANDARD GUIDELINES FOR THE COLLECTION AND DEPICTION OF EXISTING SUBSURFACE UTILITY DATA." THE CONTRACTOR AND/OR SUBCONTRACTORS SHALL DETERMINE THE EXACT LOCATION OF ALL EXISTING UTILITIES BEFORE COMMENCING WORK, BY CONTACTING THE NOTIFICATION CENTER (GOPHER STATE ONE FOR MINNESOTA). THE CONTRACTOR AND/OR SUBCONTRACTOR AGREE TO BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES, WHICH MIGHT BE OCCASIONED BY HIS OR HER FAILURE TO EXACTLY LOCATE AND PRESERVE ANY AND ALL UTILITIES (UNDERGROUND AND OVERHEAD). IF THE CONTRACTOR ENCOUNTERS ANY DRAIN TILE WITHIN THE SITE, HE OR SHE SHALL NOTIFY THE ENGINEER WITH THE LOCATION, SIZE, INVERT AND IF THE TILE LINE IS ACTIVE. NO DRAIN TILE SHALL BE BACKFILLED WITHOUT APPROVAL FROM THE PROJECT ENGINEER. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES WHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THE PLANS. NOTE: CONTRACTOR AND MATERIAL SUPPLIER SHALL DETERMINE THE MINIMUM DIAMETER REQUIRED FOR EACH STORM SEWER STRUCTURE. Project Location Date Submittal / RevisionNo. Certification Sheet Title Summary Revision History Sheet No.Revision Project No. By Designed:Drawn: Approved:Initial Issue: Phase: Client PAXMAR, LLC. 2850 CUTTERS GROVE AVE SUITE 207 ANOKA, MN 55303 MISKE MEADOWS SEVENTH ADDITION ELK RIVER, MN ETL CJS ETL CONSTRUCTION 04/26/2021 A 20460.70 I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly licensed professional ENGINEER under the laws of the state of Minnesota. If applicable, contact us for a wet signed copy of this plan which is available upon request at Sambatek's, Minnetonka, MN office. Registration No.Date:04/26/202150475 Eric T. Luth A 05/17/21 JB REVISE STORM THESE RECORD PLANS HAVE BEEN PREPARED, IN PART, BASED ON INFORMATION COMPILED AND FURNISHED BY OTHERS. THE ENGINEER HAS NOT VERIFIED THE ACCURACY AND/OR COMPLETENESS OF THE INFORMATION PROVIDED AND SHALL NOT BE RESPONSIBLE FOR ANY ERRORS OR OMISSIONS WHICH HAVE BEEN INCORPORATED INTO THESE RECORD PLANS AS A RESULT. SAMBATEK, INC. 09/27/21 C.W. HOULE INC. C.W. HOULE INC. COMPLETED BY: DATE OF COMPLETION: STREET/UTILITY CONTRACTOR: GRADING CONTRACTOR: RECORD PLAN NOTES