Loading...
MISKE7_21_51801A 1801B 2000C-2 63 62 61 1802 1801 1803 2801 2800 1800 1801A 1801B EX. 1801 2000C-2 2+003+00 4+00 5+00 6+007+008+00948.2946.2 944.1 942. 0 939.9937.9935.8947.2945.1 943.1 941.0938.9936.8FILLMOREDRIVEEOF 929 . 0 EO F 93 6 . 5EOF938.6#324 #325 #326 #459 #460 #461 #410 #409 #408 #407 #406 #405 #404 #315 #316 #317 #318 OUT BOTHWL INFILT R A T I O N BASIN 1 0 BTM: 9 2 6 . 5 ( 5 , 3 0 0 S F ) OUT: 927.0HWL: 928.8EOF: 929.0 STORM 1801B - 1801-24 910 920 930 940 950 960 910 920 930 940 950 960 STORM 1601 - 1604 910 920 930 940 950 910 920 930 940 950 STORM 1605 - 1604-26 910 920 930 940 950 910 920 930 940 950 33 LF - 12" RCP @ 2.00%CB 1801B (24"X36")RE=943.58BLD=6.6'IE=937.03 SECBMH 1801A (48")RE=943.75BLD=7.5'IE=936.36 NWIE=936.36 SW161 LF - 15" RCP @ 2.16% 8 LF - 15" RCP @ 2.20%CBMH EX. 1801 (48")RE=940.21BLD=7.5'IE=932.70 NE (VERIFY)91 LF - 15" RCP @ 0.50%CBMH 1603 (48")RE=927.74BLD=4.5'IE=923.26 SIE=923.26 N84 LF - 12" RCP @ 0.52%CB 1604 (24"X36")RE=927.73BLD=4.0'IE=923.70 N47 LF - 18" RCP @ 0.89%CB 1605 (24"X36")RE=926.90BLD=4.0'IE=922.90 ECBMH 1602 (48")RE=926.91BLD=4.1'IE=922.80 SIE=922.78 WIE=922.80 N31 LF - 15" RCP @ 0.40%FES 1600FLEXAMAT OR APPROVED EQUALIE=920.0 SE (24" )CBMH 1602 (48")RE=926.91BLD=4.1'IE=922.80 SIE=922.78 WIE=922.80 N8" SAN XING IE=916.0 8" WM XING APPRX. 8" SAN XING IE=932.1 8" WM XING STORM 1601 - 1606 910 920 930 940 950 910 920 930 940 950 Structure Table STR. # 1601 1602 1603 1604 1605 1607 1801A 1801B TYPE CBMH CBMH CBMH CB CB CB CBMH CB CASTING CONNECT TO EXISTING 15" STORM SEWER STUB ELEV=932.88 (FIELD VERIFY) R-3067-V R-3067-VBI R-3067-V R-3067-V R-3067-VBI R-4342 R-3067-V R-3067-V CBMH 1601 (60")W/ SAFL BAFFLERE=927.3BLD=9.5'IE=917.71 (3.5' SUMP)IE=922.38 SIE=921.21 EIE=921.21 NWCB 1607 (48")RE=925.85BLD=3.1'IE=922.74 W219 LF - 18" RCP @ 0.70% 121 LF - 24" RCP @ 1.00%CBMH 1601 (60")W/ SAFL BAFFLERE=927.3BLD=9.5'IE=917.71 (3.5' SUMP)IE=922.38 SIE=921.21 EIE=921.21 NW12" WM XING APPRX.943.75935.907.9'935.90943.49936.726.8'2.34%940.12932.387.7'2.08%927.079.2'920.08921.11921.11921.110.87%926.613.8'922.86922.86922.863.50%927.103.9'923.20923.200.37%927.563.8'923.760.67%926.613.8'922.86922.86922.86926.743.7'923.040.55%927.07921.119.2'921.11921.11925.29923.172.8'0.95% 35 161 119 50 91 83 33 216 932.55 917.921604 1603 1602 1605 66 1604 1603 1602 1601 1607 1600 927.5 1 LP 0+00 1+ 0 0 2 + 0 0 927.9 92 9 . 3 928. 3 9 3 0 . 8927.32LP927.32LP8+009+0010+0011+0012+0013+00928.5928.0927.5927.7930.5934.8928.2927.8927.3928.8932.4937.4IVANHOE DRIVE1 8 8 T H IVANHOEDRIVEA V E EOF 927. 9 E O F 92 7 . 9 #254 #256 #257 #258 #255 #302 #303 #304 #305 SCALE IN FEET 0 10050 NORTH Sep 27, 2021 - 12:49pm - User:tkeeley L:\PROJECTS\20460.70\CAD\Record Plans\Miske Meadows 7th Addition Record Plan Sheets\20460.70-RP-C7-STORM.dwg C7.02 STORM SEWER PLAN (1800) & (1600) LEGEND EASEMENT WATERMAIN SANITARY SEWER EXISTINGPROPOSED STORM SEWER CURB & GUTTER D S S SANITARY SERVICE WATER SERVICE PROPERTY LINE D S S FUTURE SCALE HORIZONTAL: 1"=50' VERTICAL: 1"=10' THE SUBSURFACE UTILITY INFORMATION SHOWN ON THESE PLANS IS A UTILITY QUALITY LEVEL D. THIS QUALITY LEVEL WAS DETERMINED ACCORDING TO THE GUIDELINES OF ASCE/CI 38-02, TITLED "STANDARD GUIDELINES FOR THE COLLECTION AND DEPICTION OF EXISTING SUBSURFACE UTILITY DATA." THE CONTRACTOR AND/OR SUBCONTRACTORS SHALL DETERMINE THE EXACT LOCATION OF ALL EXISTING UTILITIES BEFORE COMMENCING WORK, BY CONTACTING THE NOTIFICATION CENTER (GOPHER STATE ONE FOR MINNESOTA). THE CONTRACTOR AND/OR SUBCONTRACTOR AGREE TO BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES, WHICH MIGHT BE OCCASIONED BY HIS OR HER FAILURE TO EXACTLY LOCATE AND PRESERVE ANY AND ALL UTILITIES (UNDERGROUND AND OVERHEAD). IF THE CONTRACTOR ENCOUNTERS ANY DRAIN TILE WITHIN THE SITE, HE OR SHE SHALL NOTIFY THE ENGINEER WITH THE LOCATION, SIZE, INVERT AND IF THE TILE LINE IS ACTIVE. NO DRAIN TILE SHALL BE BACKFILLED WITHOUT APPROVAL FROM THE PROJECT ENGINEER. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES WHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THE PLANS. NOTE: CONTRACTOR AND MATERIAL SUPPLIER SHALL DETERMINE THE MINIMUM DIAMETER REQUIRED FOR EACH STORM SEWER STRUCTURE. LOWER AND INSULATE WATER SERVICE LOWER AND INSULATE WATER SERVICE REMOVE EXISTING CBMH REMOVE & SALVAGE EXISTING 18" PIPE. INSTALL 24" RCP @ 1.00% REMOVE & SALVAGE 18" FES, ADD ADDITIONAL FLEXAMAT AS REQUIRED TO ACCOMODATE 24" FES VERIFY RIM ELEVATION AND ADJUST AS NECESSARY INSTALL CASTING REMOVE & SALVAGE EXISTING 18" STORM SEWER & FES REPLACE WITH 24" STORM SEWER AND 24" FES REMOVE AND REPLACE TEMPORARY HDPE PIPE WITH RCP OF EQUIVALENT SIZE INSULATE INSULATE GRADE TO DRAIN TO CB 1607 AS NECESSARY A A AA Project Location Date Submittal / RevisionNo. Certification Sheet Title Summary Revision History Sheet No.Revision Project No. By Designed:Drawn: Approved:Initial Issue: Phase: Client PAXMAR, LLC. 2850 CUTTERS GROVE AVE SUITE 207 ANOKA, MN 55303 MISKE MEADOWS SEVENTH ADDITION ELK RIVER, MN ETL CJS ETL CONSTRUCTION 04/26/2021 A 20460.70 I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly licensed professional ENGINEER under the laws of the state of Minnesota. If applicable, contact us for a wet signed copy of this plan which is available upon request at Sambatek's, Minnetonka, MN office. Registration No.Date:04/26/202150475 Eric T. Luth A 05/17/21 JB REVISE STORM THESE RECORD PLANS HAVE BEEN PREPARED, IN PART, BASED ON INFORMATION COMPILED AND FURNISHED BY OTHERS. THE ENGINEER HAS NOT VERIFIED THE ACCURACY AND/OR COMPLETENESS OF THE INFORMATION PROVIDED AND SHALL NOT BE RESPONSIBLE FOR ANY ERRORS OR OMISSIONS WHICH HAVE BEEN INCORPORATED INTO THESE RECORD PLANS AS A RESULT. SAMBATEK, INC. 09/27/21 C.W. HOULE INC. C.W. HOULE INC. COMPLETED BY: DATE OF COMPLETION: STREET/UTILITY CONTRACTOR: GRADING CONTRACTOR: RECORD PLAN NOTES