Loading...
WINDSORSEWER_14935 940 945 950 955 960 965 970 975 980 935 940 945 950 955 960 965 970 975 980 954.04954.055+00 954.72954.7955.45955.455+50 955.86955.9956.32956.356+00 957.04957.0957.61957.656+50 957.82957.8958.35958.357+00 959.04959.0959.19959.257+50 960.37960.4961.16961.258+00 962.29962.3964.09964.158+50 964.50964.5964.40964.459+00 965.45965.4966.60966.659+50 967.44967.4968.49968.560+00 969.46969.5969.93969.960+50 971.09971.1971.74971.761+00 972.27972.3973.15973.261+50 974.01974.0974.97975.062+00 975.82975.8976.07976.162+50 2.00% 4.00% VPI: 62+25.42 EL: 965.86 A = -2.88% K = 104.10 L=300' VPI: 58+75.42 EL: 951.86 A = 2.00% K = 150.00 L=300'VPC: 60+75.42EL: 959.86VPT: 60+25.42EL: 957.86VPC: 57+25.42EL: 948.86STA: 55+00.00 ELEV: 944.30 STA: 62+50.00 ELEV: 965.32 275' - 6" SAN FM @ 12" STM INV = 959.39 8' MIN COVER RANCH ROAD NORTHWEST / COUNTY ROAD 33 12" CM P YORK STREET NORTHWEST128781280612760PT: 55+75.62l l l l l l l l l l l l l l l l l l l l l l l l l l l ll l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l>>55+00 56+00 57+00 58+00 59+00 60+00 61+00 62+00 6" SAN FM 6" SAN FM G I=959.33C GOU GGE E E E E E E E E E E E E E E E E E E E E E E E E E EG G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C SHEET DATELIC. NO. I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION, OR REPORT WAS PREPAREDBY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF MINNESOTA. Bolton & Menk, Inc. 2020, All Rights ReservedcH:\ELKR\R19122405\CAD\C3D\122405_C_ALGN_1.dwg 9/17/2020 10:24:19 AMDESIGNED DRAWN CHECKED CLIENT PROJ. NO. ISSUED FOR DATENO. R 7533 SUNWOOD DR NW, SUITE 206 RAMSEY, MINNESOTA 55303 Phone: (763) 433-2851 Email: Ramsey@bolton-menk.com www.bolton-menk.com OF JASON W. COOK, P.E. 47451 09/08/2020 ELK RIVER, MINNESOTA WINDSOR PARK 3RD. ADDITION - SEWER EXTENSION JWC KGA JWC R19.122405 16 R SANITAY SEWER PLAN AND PROFILE 14 FEETSCALE 0 25 50 HORZ. FEETSCALE 0 5 10 VERT. 6" SANITARY FORCEMAIN (DIRECTIONALLY DRILLED) LEGEND EXISTING DRAINAGE FLOW BITUMINOUS PATCH EROSION CONTROL BLANKET, SEED & FERTILIZER AGGREGATE SHOULDER SEDIMENT CONTROL LOG EXISTING GROUND PROFILE OVER PROPOSED FORCEMAIN THIS RECORD DRAWING HAS BEEN PREPARED, IN PART, BASED UPON INFORMATION FURNISHEDBY OTHERS. WHILE THIS INFORMATION IS BELIEVED TO BE RELIABLE, BOLTON & MENK, INC.CANNOT ASSURE ITS ACCURACY, AND THUS IS NOT RESPONSIBLE FOR THE ACCURACY OF THISRECORD DRAWING OR FOR ANY ERRORS OR OMISSIONS WHICH MAY HAVE BEEN INCORPORATEDINTO IT AS A RESULT. THOSE RELYING ON THIS DOCUMENT ARE ADVISED TO OBTAININDEPENDENT VERIFICATION OF ITS ACCURACY BEFORE APPLYING IT FOR ANY PURPOSE.DATE: 02/14/2022 COMPLETED BY: TJH