Loading...
WINDSORSEWER_3SHEET DATELIC. NO. I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION, OR REPORT WAS PREPAREDBY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF MINNESOTA. Bolton & Menk, Inc. 2021, All Rights ReservedcH:\ELKR\R19122405\CAD\122405G003.dwg 3/22/2021 3:35:50 PMDESIGNED DRAWN CHECKED CLIENT PROJ. NO. ISSUED FOR DATENO. R 7533 SUNWOOD DR NW, SUITE 206 RAMSEY, MINNESOTA 55303 Phone: (763) 433-2851 Email: Ramsey@bolton-menk.com www.bolton-menk.com OF JASON W. COOK, P.E. 47451 09/08/2020 ELK RIVER, MINNESOTA WINDSOR PARK 3RD. ADDITION - SEWER EXTENSION JWC KGA JWC R19.122405 16SANITARY SEWER DETAILS 3 NOT TO SCALE GROUT INVERT 3/4" CRUSHED ROCK PRECAST CONCRETE BASE FORCEMAIN 2" STAINLESS STEEL TAPPING SADDLE AND BALL VALVE STEEL REINFORCED PLASTIC STEPS COMBINATION AIR VACUUM RELEASE VALVE WITH ACCESSORIES MnDOT DESIGN 54-4020 MANHOLE MIN 3 - MAX 6 CONCRETE ADJUSTING RINGS WITH NON-SHRINK GROUT AND PLASTERED 1/2" THICK INSIDE AND OUT CASTING AS SPECIFIED 1" SCHEDULE 80 PVC OUTLET ARM 54" Ø MH AIR RELEASE MANHOLE DESIGN 4020 SANITARY MANHOLE NOT TO SCALE FLOW PLAN VIEW 27"48"16"5" 48"VARIES1.RUBBER GASKET (TYPICAL) 2.FLEXIBLE WATERTIGHT SEAL TO BE APPROVED BY ENGINEER 3.SHAPE, DEPTH AND SLOPE OF INVERT TO BE APPROVED BY ENGINEER 4.STEEL REINFORCED PLASTIC STEPS SHALL BE A POLYPROPYLENE PLASTIC REINFORCED WITH A NO. 2 DEFORMED STEEL ROD GRADE 60 5.MnDOT TYPE "B" ECCENTRIC PRECAST CONCRETE CONE SECTION TYPICAL FOR ALL MANHOLES 6.PLACE INTERIOR CHIMNEY SEAL (WHEN SPECIFIED) 7.8" WIDE, 14" THICK BITUMINOUSMASTIC WRAP FULL CIRCUMFERENCE (WHEN SPECIFIED) STEPS OVER OUTLET IF REQUIRED 6" MIN INTEGRAL PRECAST CONCRETE BASE 7 7 6 MIN 3 MAX 6 CONCRETE ADJUSTING RINGS WITH NON-SHRINK GROUT AND PLASTERED 1/2" THICK INSIDE AND OUT CASTING AS SPECIFIED WITH CONCEALED PICKHOLES 5 1 4 2 2 3 REFER TO PLANS FOR PIPE REQUIRED BOLLARD GUARD POST NOT TO SCALE 16"6"3'-0"4'-0"CONCRETE ONE WRAP OF 30# ROOFING FELT 8" DIA CONCRETE-FILLED STANDARD STEEL BOLLARD EXISTING GRADE 4"RNOT TO SCALE 2.5" TYPE SP 9.5 WEARING COURSE MIXTURE (2,B) (SPWEA240B) (2360) SUBGRADE PREPARATION (2112) (INCIDENTAL) 6" AGGREGATE BASE, CL 5 (SPEC 2211) (INCIDENTAL) BITUMINOUS TRAIL PATCH - TYPICAL SECTION GREAT NORTHERN TRAIL NOT TO SCALE 2.0" TYPE SP 12.5 WEARING COURSE, (SPWEA240B) (SPEC 2360) 2.0" TYPE SP 12.5 NON WEARING COURSE, (SPNWB230B) (SPEC 2360) SUBGRADE PREPARATION (2112) (INCIDENTAL) BITUMINOUS TACK COAT (SPEC 2357) (INCIDENTAL) 12" AGGREGATE BASE, CL 5 (SPEC 2211) (INCIDENTAL) BITUMINOUS ROAD PATCHING - TYPICAL SECTION COUNTY ROAD 33 - RANCH ROAD CONCRETE PAVEMENT NOT TO SCALE 7" CONCRETE PAVEMENT (2531) 4" AGGREGATE BASE, CL 5 (2211) (INCIDENTAL) SUBGRADE PREPARATION (2112) (INCIDENTAL) BITUMINOUS TACK COAT (SPEC 2357) (INCIDENTAL) 2.0" TYPE SP 12.5 WEARING COURSE, (SPWEA240B) (SPEC 2360) 6" SANITARY SEWER SERVICE RISER, NEW CONSTRUCTION NOT TO SCALE FLOW NOTES: 1. SADDLES, BENDS AND PIPE SIZES AS REQUIRED BY PLANS AND SPECS 2. INSTALL TRACER WIRE AS DETAILED IN THE SPECIFICATIONS 8" HDPE SANITARY SEWER PIPE 8" X 4" SADDLE 45° BEND RISER ON UNDISTURBED TRENCH WALL SEWER SERVICE SLOPE REQUIREMENTS OPTIMUM 2.0%-MAX 10.0% 2"X2" WOOD MARKER (INCIDENTAL) 2"X4" WOOD MARKER 4' MIN ABOVE GRADE PAINTED GREENUTILITYEASEMENTLINER/W LINEFINISHED SURFACE 4" PLUG TRACER WIRE BEND AS REQUIRED (45° MAX PER BEND) 1/2"x24" STEEL LOCATING ROD (INCIDENTAL) 1 CO - 1 03/23/2021 I = 928.75 1 THIS RECORD DRAWING HAS BEEN PREPARED, IN PART, BASED UPON INFORMATION FURNISHEDBY OTHERS. WHILE THIS INFORMATION IS BELIEVED TO BE RELIABLE, BOLTON & MENK, INC.CANNOT ASSURE ITS ACCURACY, AND THUS IS NOT RESPONSIBLE FOR THE ACCURACY OF THISRECORD DRAWING OR FOR ANY ERRORS OR OMISSIONS WHICH MAY HAVE BEEN INCORPORATEDINTO IT AS A RESULT. THOSE RELYING ON THIS DOCUMENT ARE ADVISED TO OBTAININDEPENDENT VERIFICATION OF ITS ACCURACY BEFORE APPLYING IT FOR ANY PURPOSE.DATE: 02/14/2022 COMPLETED BY: TJH