Loading...
WINDSORSEWER_4SHEET DATELIC. NO. I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION, OR REPORT WAS PREPAREDBY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF MINNESOTA. Bolton & Menk, Inc. 2020, All Rights ReservedcH:\ELKR\R19122405\CAD\122405G003.dwg 9/17/2020 10:18:07 AMDESIGNED DRAWN CHECKED CLIENT PROJ. NO. ISSUED FOR DATENO. R 7533 SUNWOOD DR NW, SUITE 206 RAMSEY, MINNESOTA 55303 Phone: (763) 433-2851 Email: Ramsey@bolton-menk.com www.bolton-menk.com OF JASON W. COOK, P.E. 47451 09/08/2020 ELK RIVER, MINNESOTA WINDSOR PARK 3RD. ADDITION - SEWER EXTENSION JWC KGA JWC R19.122405 16EROSION CONTROL DETAILS 4 NOT TO SCALE DITCH CHECK - BIOROLL FLOW CATEGORY 3 EROSION CONTROL BLANKET NOTE: POINT 'A' MUST BE 1'-0" MIN HIGHER THAN POINT 'B' TO ENSURE THAT WATER FLOWS OVER THE DITCH CHECK AND NOT AROUND THE ENDS 12' M I N BLA N K E T S M U S T OV E R L A P B Y 4 " M I N 2"x2"x16" LONG WOOD STAKES AT 2'-0" SPACING DRIVE THROUGH NETTING AND FIBER ROLL 6", 11ga STAPLES SPACED 1'-0" ON CENTER POINT 'A'POINT 'B' 4"x4" TRENCH BACKFILLED OVER EROSION CONTROL BLANKET 6"-7" DIA STRAW OR WOOD FIBER ROLL ENCLOSED IN PLASTIC OR POLYESTER NETTING EROSION CONTROL BLANKET INSTALLATION ANCHOR SLOT ALTERNATIVE NOT TO SCALE 3' LEVEL (MIN) NOTE: ANCHOR, OVERLAP & STAPLE PER MANUFACTURER'S SPECIFICATIONS FOLD UNDER 6" 1' SPACING ON STAPLES 4" OVERLAP SILT FENCE - PREASSEMBLED NOT TO SCALE30" MIN1'-6" MINPOSTEMBEDMENT6" MIN 6"MINDIRECTION OF RUNOFF FLOW NOTE: 1.GEOTEXTILE FABRIC SHALL BE PER MnDOT SPEC 3886 EXTEND FABRIC INTO TRENCH FABRIC ANCHORAGE TRENCH BACKFILL WITH TAMPED NATURAL SOIL GEOTEXTILE FABRIC, 36" WIDE (SEE NOTE 1) STAPLES 2"x2" WOOD POST 5' MINIMUM LENGTH POSTS AT 6' MAXIMUM SPACING ROCK CONSTRUCTION ENTRANCE NOT TO SCALE 6" MIN THICKNESS 7 5 ' M IN IMUM 25' MI NI M U M SILT FENCE TO TIE INTO BERM OF ROCK ACCESS EACH SIDE 3" MINUS WASHED COARSE AGGREGATE (OR APPROVED EQUAL) PROVIDE RADIUS AS NEEDED (TYP) HARD SURFACE PUBLIC ROAD 16" MIN CUT OFF BERM TO MINIMIZE RUNOFF FROM SITE MnDOT TYPE V (3733) GEOTEXTILE FABRIC SHALL BE PLACED UNDER ROCK TO STOP MUD MIGRATION THROUGH ROCK THIS RECORD DRAWING HAS BEEN PREPARED, IN PART, BASED UPON INFORMATION FURNISHEDBY OTHERS. WHILE THIS INFORMATION IS BELIEVED TO BE RELIABLE, BOLTON & MENK, INC.CANNOT ASSURE ITS ACCURACY, AND THUS IS NOT RESPONSIBLE FOR THE ACCURACY OF THISRECORD DRAWING OR FOR ANY ERRORS OR OMISSIONS WHICH MAY HAVE BEEN INCORPORATEDINTO IT AS A RESULT. THOSE RELYING ON THIS DOCUMENT ARE ADVISED TO OBTAININDEPENDENT VERIFICATION OF ITS ACCURACY BEFORE APPLYING IT FOR ANY PURPOSE.DATE: 02/14/2022 COMPLETED BY: TJH