Loading...
WINDSORSEWER_6M Ts TsSPAN TbTtRISEAs5 As7 As2 As1As4 As8 As3 As5 As6 As6 As6 As5 NO. 3 HAUNCH BARS @ 1'-0" SPACING (TYP.) X VALVE VAULT REINFORCING SIZE f'c (P.S.I) DIMENSIONS WELDED WIRE REINFORCEMENT SHEAR REINFORCEMENT TOP AND BOTTOM OF BARRELAs1As2As3As4As5As6As7As8 SPAN (FT.)RISE (FT.)Tt (IN.)Tb (IN.)Ts (IN.)AREA (IN.2/FT.) M (FT.)AREA (IN.2/FT.) AREA (IN.2/FT.) AREA (IN.2/FT.) AREA (IN.2/FT.) AREA (IN.2/FT.) AREA (IN.2/FT.) AREA (IN.2/FT.) AREA (IN.2/FT.) MAX. SPG. (IN.) X (IN.) 14'-0" x 6'-0"5000 14 6 12 12 12 1.06 4'-6"1.06 1.06 1.06 0.46 0.46 0.29 0.29 0.09 4 16 ANCHOR BOLTS. VERIFY SIZE & LOCATION WITH GENERATOR SUPPLIER 5'-6" X 10'-9" X 1'-0" THICKCONCRETE SLAB W/ #5 @12"OC, EW, EF, TYP 3/4" CHAMFER, TYP 1 1 1'-0" THICK MIN. COMPACTEDSELECT GRANULAR BORROW COMPACT EXISTINGSUBGRADE SOILS BASE SLAB WALL BASE SLAB WALL PREFORMED JOINT SEALANT JOINT DRYPACK GROUT EXTERNAL JOINT WRAP PREFORMED JOINT SEALANTJOINT DRYPACK GROUT EXTERNAL JOINT WRAP PREFORMED JOINT SEALANT JOINT DRYPACK GROUT EXTERNAL JOINT WRAP GENERAL NOTES: ·1 1/2" MIN AND 2" MAX CONCRETE COVER ON ALL REINFORCEMENT ·REINFORCEMENT AREA BASED GRADE 60 REINFORCEMENT. WELDED WIRE FABRIC MAY BE USED IN PLACE OF REINFORCEMENT. ADJUST AREA OF REINFORCEMENT BASED ON RATIO OF YIELD STRENGTHS. B LIFT STATION GENERATOR PAD DETAIL NOT TO SCALE LIFT STATION STRUCTURAL DETAILS 6 B JOINT DETAIL NOT TO SCALE A LIFT STATION - VALVE VAULT REINFORCING PLAN 1/2" = 1'-0" SHEET DATELIC. NO. I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION, OR REPORT WAS PREPAREDBY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF MINNESOTA. Bolton & Menk, Inc. 2020, All Rights ReservedcH:\ELKR\R19122405\CAD\C3D\122405_S_BASE_N1.dwg 9/17/2020 10:18:38 AMDESIGNED DRAWN CHECKED CLIENT PROJ. NO. ISSUED FOR DATENO. R 7533 SUNWOOD DR NW, SUITE 206 RAMSEY, MINNESOTA 55303 Phone: (763) 433-2851 Email: Ramsey@bolton-menk.com www.bolton-menk.com OF JASON W. COOK, P.E. 47451 09/08/2020 ELK RIVER, MINNESOTA WINDSOR PARK 3RD. ADDITION - SEWER EXTENSION JWC KGA JWC R19.122405 16 THIS RECORD DRAWING HAS BEEN PREPARED, IN PART, BASED UPON INFORMATION FURNISHEDBY OTHERS. WHILE THIS INFORMATION IS BELIEVED TO BE RELIABLE, BOLTON & MENK, INC.CANNOT ASSURE ITS ACCURACY, AND THUS IS NOT RESPONSIBLE FOR THE ACCURACY OF THISRECORD DRAWING OR FOR ANY ERRORS OR OMISSIONS WHICH MAY HAVE BEEN INCORPORATEDINTO IT AS A RESULT. THOSE RELYING ON THIS DOCUMENT ARE ADVISED TO OBTAININDEPENDENT VERIFICATION OF ITS ACCURACY BEFORE APPLYING IT FOR ANY PURPOSE.DATE: 02/14/2022 COMPLETED BY: TJH