Loading...
LEACHATE_5 Bolton & Menk, Inc. 2019, All Rights ReservedcH:\WASTEMAN_PR\R16115896\CAD\ENV\Plant 3D\Waste Management Lift Station 1\Orthos\DWGs\Meter MH Vault 13.dwg 2/28/2019 11:32 PMTOP PLAN - METER VAULT SCALE: 3/8"=1'-0" 1 ? 1 ? 2'-6" CLEAR OPENING ℄ VALVE/ METER VAULT 15'-8"1'-6"1'-4"7'-8"2 #5 DIAG. EA CORNER (TYP) 2 ADD'L #5 EA SIDE OF OPENING (TYP) 30"x36" CLEAR OPENING ACCESS HATCH W/ SAFETY GRATING CAST INTO TOP SLAB. VERIFY SIZE AND LOCATION WITH ENGINEER.3'-0"6" SCH 40 WELDED STEEL PIPE VENT WITH SEEPAGE COLLAR CAST INTO TOP SLAB. INCLUDE BIRD SCREEN. NOTE: SEE SECTION 1 FOR ADDITIONAL TOP SLAB REINFORCING R PLAN - METER VAULT SCALE: 3/8"=1'-0"R12'-0"6'-0"℄ VALVE/ METER VAULT 1 ?1 ? 6" DIP FORCEMAIN 6" MJ COUPLING 6" HDPE FORCEMAIN ℄ ELEV.=953.52 1'-6"2'-6" 6" GATE VALVE 6" METER 6" DIP FORCEMAIN 30"x36" CLEAR OPENING ACCESS HATCH W/ SAFETY GRATING CAST INTO TOP SLAB. VERIFY SIZE AND LOCATION WITH PUMP MANUFACTURER. 1'-0"1'-0" PRECAST CONCRETE VALVE/METER VAULT FE 2 SLOPE GROUT TO SUMP SEE REINFORCEMENT SCHEDULE SHEET 7 18"X18"X3" SUMP 6" GATE VALVE 6" HDPE FORCEMAIN ℄ ELEV.=953.52 12" HDPE CASING PIPE12" HDPE CASING PIPE 6" MJ COUPLING SECTION - METER VAULT SCALE: 3/8"=1'-0" 1 D# BASE ELEV.=951.502'-014"NOTES: 1.ALL INTERIOR PIPING IN WET WELL SHALL BE STAINLESS STEEL AS SHOWN. 2.ALL INTERIOR PIPING IN VALVE/METER VAULT SHALL BE FLANGED FITTINGS AS SHOWN. 3.ALL EXTERIOR PIPING SHALL BE MECHANICAL JOINT WITH MEGALUG RESTRAINT JOINTS. 4.FLEXIBLE WATERTIGHT SEAL TO BE PROVIDED AT ALL PIPE PENETRATIONS AT VALVE VAULT AND LIFT STATION. FLEXIBLE WATERTIGHT SEAL TO BE APPROVED BY ENGINEER. 5.CONTRACTOR SHALL VERIFY EXISTING FORCEMAIN ELEVATION. NOTE: PIPING ROTATED FOR CLARITY SEE PLAN FOR ORIENTATION. 12" COMPACTED GRANULAR FILL SLOPE GROUT TO SUMP PIPE SUPPORT (TYPICAL) PIPE SUPPORT (TYPICAL) 10'-0"x18'-0"x12" THICK BASE 9"18"X18"X3" SUMP3"1'-6" #5 @ 8" O.C. EW TOP (TYP) #5 @ 12" O.C. EW BOTTOM (TYP) 2" CLEAR COVER EF 6" HDPE FORCEMAIN ℄ ELEV.=953.52 12" HDPE CASING PIPE 6" SCH 40 WELDED STEEL PIPE VENT WITH SEEPAGE COLLAR CAST INTO TOP SLAB. INCLUDE BIRD SCREEN. 30"x36" CLEAR OPENING ACCESS HATCH W/ SAFETY GRATING CAST INTO TOP SLAB. VERIFY SIZE AND LOCATION WITH PUMP MANUFACTURER.2'-6"PRECAST CONCRETE VALVE/METER VAULT ELEV.=971.00 12" THICK PRECAST TOP SLAB REFER TO SITE PLAN FOR GRADING AROUND LIFT STATION AND VALVE/METER VAULT. ELEV.=970.00 3 EQUAL SECTION HEIGHTSREINFORCING #5 @ 8" O.C. EW BOTTOM (TYP) #5 @ 12" O.C. EW TOP (TYP) 2" CLEAR COVER EF 6" DIP FORCEMAIN 6" MJ COUPLING 6" HDPE FORCEMAIN ℄ ELEV.=953.52 1'-6"2'-6" 6" GATE VALVE 6" METER FE 2 6" GATE VALVE 12" HDPE CASING PIPE 6" MJ COUPLING VALVE EXTENSIONSTEM WITH NUTVALVE BOX CAST INTO TOP SLAB VALVE EXTENSIONSTEM WITH NUTVALVE BOX CAST INTO TOP SLAB DATE LIC. NO. I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION, OR REPORT WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF MINNESOTA. SHEET Bolton & Menk, Inc. 2019, All Rights ReservedcH:\WASTEMAN_PR\R16115896\CAD\ENV\Plant 3D\Waste Management Lift Station 1\Orthos\DWGs\Meter MH Vault 13.dwg 3/1/2019 4:00:02 PMDESIGNED DRAWN CHECKED CLIENT PROJ. NO. REVISION DATENO. R 7533 SUNWOOD DR NW, SUITE 206 RAMSEY, MINNESOTA 55303 Phone: (763) 433-2851 Email: Ramsey@bolton-menk.com www.bolton-menk.com OFSINATURE:PRINTED NAME: TYPED OR Tejpal Singh Bala 4957403/01/2019 ELK RIVER LANDFILL INC. WASTE WATER FORCEMAIN TSB TMJ TSB R16.115896 46METER MANHOLE VAULT 13 PLAN & SECTION 5CONTRACTOR: Minger Construction RECORD PLAN ZGN 12-22-2020 8643210 Graphic Scale for 3/8"=1'-0"