Loading...
LEACHATE_8SHEET DATELIC. NO. I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION, OR REPORT WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSEDPROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF MINNESOTA. Bolton & Menk, Inc. 2019, All Rights ReservedcH:\WASTEMAN_PR\R16115896\CAD\C3D\115896G003.dwg 3/1/2019 4:00:10 PMDESIGNED DRAWN CHECKED CLIENT PROJ. NO. REVISION DATENO. R 7533 SUNWOOD DR NW, SUITE 206 RAMSEY, MINNESOTA 55303 Phone: (763) 433-2851 Email: Ramsey@bolton-menk.com www.bolton-menk.com OF Kevin F. Bittner21814 03/01/2019 ELK RIVER LANDFILL INC. WASTE WATER FORCEMAIN KFB KGA KFB R16.115896 46DETAILS 7 INTERNATIONAL HANDICAP SYMBOLHANDICAP PARKING STRIPING 90° STALL NOT TO SCALENOT TO SCALE 16' VAN HANDICAP 16' HANDICAP 8' MIN 8' MIN 8' MIN 8' MIN 20' TYP4" TYP1'-0"2'-0"1'-0"4"1'-0"6"C/L OF PARKING SPACE 1'-6" 36" MIN ACCESSIBLE ROUTE 6" 23° REFLECTIVE PAINT R6 " 5°0'0" R 2 ' 3" DISABLED PARKING SIGN NOT TO SCALE PARKING VEHICLE IDREQUIRED UP TO $200 FINEFOR VIOLATION 1'-6"4'-0"5'-0"6"GRADE AIR-DRIVE POST AS SHOWN 3" GALVANIZED STEEL POST TYP EACH HANDICAP PARKING STALL R7-8b FOR VAN ACCESSIBLE SPACES ONLY R7-8m VANACCESSIBLE 1 3 3'2.5'TOP OF LANDFILL CAP STA. 233+50 TO 248+50 NOT TO SCALE FORCEMAIN COVER BERM GRANULAR ENCASEMENT DUAL CONTAINMENT FORCEMAIN COMMON BORROW SUPPLIED BY LANDFILL NON-RIGID SANITARY SEWER TRENCH NOT TO SCALE OD + 24" TRACER WIRE AS SPECIFIED, TAPE TO PIPE AT 5' INTERVAL, PLACE WIRE BELOW SPRING LINE GRANULAR BEDDING AND ENCASEMENT MATERIAL AS SPECIFIED COMPACTED BACKFILL AS SPECIFIED OD PIPE MATERIAL AS SPECIFIED 12"(MIN) 6" SLOPE 1" PER FT PLACE BITUMINOUS MASTIC COMPOUND BETWEEN SECTIONS FILL ANNULAR SPACE AROUND PIPE WITH NON-SHRINK GROUT INSIDE & OUT WRAP WITH GCL REFER TO PLANS FOR PIPE REQUIREDVARIES - 4'0" MAX5" 48" 5'-2" 27" 2 1 8" MIN POURED OR PRECAST CONCRETE BASE 1 2 MIN 3 MAX 6 CONCRETE ADJUSTING RINGS WITH NON-SHRINK GROUT AND PLASTERED 1/2" THICK INSIDE AND OUT NEENAH R-1710 CASTING WITH R-2533 GRATE CATCH BASIN 22 - DESIGN G NOT TO SCALE BOLLARD GUARD POST NOT TO SCALE 16"6"3'-0"4'-0"CONCRETE ONE WRAP OF 30# ROOFING FELT 8" DIA CONCRETE-FILLED STANDARD STEEL BOLLARD EXISTING GRADE 4"RNEW SIGN POST INSTALLATION, PARKING LOT NOT TO SCALE NOTE: PAINT CONCRETE BOLLARD AND NEW/EXIST CHANNEL POST YELLOW (ABOVE GROUND)3'-0"3'-0"2'-0"HEIGTH VARIESINSTALL CHANNEL POST WITH SIGN, FIELD CUT TO APPROPRIATE LENGTH (PAINT POST YELLOW) FASTEN WITH BOLTS (2 EACH) INSTALL NEW CHANNEL POST, FIELD CUT TO APPROPRIATE LENGTH 10" DIA POURED CONCRETE BOLLARD (4,000 PSI) EXISTING GRADE BACKFILL WITH CLASS 5 AGGREGATE BASE, COMPACT R8-3 24"X24" NEW FORCEMAIN CONNECTION DETAIL NOT TO SCALEFLOWPLAN VIEW EXISTING SANITARY MANHOLE 1 EXISTING 8" SAN 6" HDPE FORCEMAIN (EXTENDED INTO STRUCTURE) B B NOTE: SECTION B CUT IS PERPENDICULAR TO EXISTING SAN EX 8" P V C 6" HDPE FMN 8' 24"EXISTING GEONET 4" POLYSTYRENE INSULATION WEST BENCH DETAIL NOT TO SCALE DUAL CONTAINMENT FORCEMAIN EXISTING TEXTURED 40 MIL GEOMEMBRANE EXISTING GEONET EXISTING BENCH PROPOSED 18" CMP EROSION CONTROL BLANKET, SEED & FERTILIZER OVER DISTURBED AREA TOP OF BERM - 6" TOPSOIL 1 3 1 3 EXISTING 4" CORRUGATED DRAINAGE TUBING 4" PROPOSED POLYSTYRENE INSULATION2.5'LANDFILL CAP ROAD CROSSING DETAIL NOT TO SCALE AGGREGATE SURFACING CL. 2 8' 4" POLYSTYRENE INSULATION 50'50' 1" STEEL ROAD PLATE EROSION CONTROL BLANKET, SEED & FERTILIZER OVER DISTURBED AREA TOP OF LANDFILL CAP 6" TOPSOIL 3 3 3 CONTRACTOR: Minger Construction RECORD PLAN ZGN 12-22-2020