9.1 SR 07-18-2022
Request for Action
To Item Number
Mayor and City Council 9.1
Agenda Section Meeting Date Prepared by
Work Session July 18, 2022 Mark Dickinson, Fire Chief
Item Description Reviewed by
Fire Department Aerial Truck Purchase Cal Portner, City Administrator
Reviewed by
Action Requested
Discuss and provide direction to staff for the purchase of a new Aerial Truck to replace the current Aerial.
Background/Discussion
The current Aerial Truck for the Fire Department is over 30 years old and is due to be replaced.
Chief Dickinson will review the need for this replacement.
Financial Impact
$1.7 Million
Mission/Policy/Goal
Elk River Vision
Attachments
None
The Elk River Vision
A welcoming community with revolutionary and spirited resourcefulness, exceptional
service, and community engagement that encourages and inspires prosperity.
Updated: August 2020
Replacement of Elk River Fire Department
Aerial Ladder Truck
BACKGROUND:
The Elk River Fire Department purchased our current Aerial truck in 1989 and it went into service
in 1990. Since then, the Aerial has been refurbished once in 2014. This piece of apparatus is an
important part of our fleet to successfully serve the community and keep firefighters safe at incident
scenes. With being over 30 years old, it has exceeded its front-line condition and is best served as a
reserve piece of apparatus. It is recommended for replacement.
NFPA 1911 STANDARDS FOR THE INSPECTION, MAINTENANCE, TESTING,
AND RETIREMENT OF IN-SERVICE AUTOMOTIVE FIRE APPARTATUS.
“Apparatus manufactured prior to 1991 usually included only a few of the safety upgrades required
by the 1991 and subsequent editions of the NFPA fire department apparatus standards or the
equivalent Underwriters’ Laboratories of Canada (ULC) standards. Because the changes, upgrades,
and fine tuning to NFPA 1901, Standard for Automotive Fire Apparatus, since 1991 have been truly
significant, especially in the area of safety, fire departments should seriously consider the value (or
risk) to fire fighters of keeping pre-1991 fire apparatus in first-line service.”
“It is recommended that apparatus manufactured prior to 1991 that is less than 25 years old, that has
been properly maintained, and that is still in serviceable condition should be placed in reserve status
and upgraded to incorporate as many features as possible of the post-1991 fire apparatus (see
Section D.3). Apparatus that was not manufactured to the applicable NFPA fire apparatus standards
or that is over 25 years old should be replaced.”
High-hazard occupancies (schools, hospitals, nursing homes, high-rise buildings): at least four
pumpers, two ladder trucks, and other specialized apparatus as may be identified or available for the
hazard. Medium-hazard occupancies (apartments, offices, mercantile and industrial occupancies not
normally requiring extensive rescue or firefighting capabilities): at least three pumpers, one ladder
truck, and other specialized apparatus as may be identified or available. Low-hazard occupancies
(one-, two-, or three-family dwellings and scattered businesses and industrial occupancies): at least
two pumpers, one ladder truck, and other specialized apparatus as may be identified or available.
AERIAL DEVICE JUSTIFICATION
The “old school “rule governing whether a fire department required an aerial device, or not,
was based on when the portable ground ladders within a fire department would no longer
reach the upper windows or the roof of buildings in the community, then an aerial device
was needed.
It typically takes three or more firefighters to raise and place a long ground ladder.
If at any given time a department has insufficient personnel to achieve this task safely and
without exposure to injury, while issuing an attack and laying out hose lines, then an aerial
device is needed.
Terrain and landscape oddities may make it impossible for firefighters to gain access to two-
or three-story structures with ground ladders
Rescue operations from a second or third story window from a ladder is extremely
dangerous to the victim as well as the firefighters
Communities with historic downtowns, large square footage buildings, such as warehouses,
large department stores, etc. require a safe means of delivery fire suppression from an
elevated position.
Interior operations in older buildings are prone to earlier collapse, aerial operations offer us a
chance to safely ventilate these structures.
New homes are 30% larger in size than what was being built prior to 2009 (We do not have 1200
sq ft ranch houses anymore.
The Fire service needs to grow with the community
ISO BENEFITS
A citation from Section 540 of the Insurance Services Office (ISO) Fire Suppression Rating
Schedule specifically states, “Response areas with 5 buildings that are 3 stories or 35 feet or
more in height, or \[have\] 5 buildings that have a Needed Fire Flow greater than 3,500 gpm, or
any combination of these criteria, should have a ladder company."
To receive the highest points in an ISO evaluation for ladder service, the ladder unit must reach
the roof of the tallest building in its service area or be one hundred’ long, whichever is less
An aerial device can significantly improve a fire district’s ISO rating, lowering a community’s
property insurance premiums.