5.2. PCSR 02-28-2023Request for Action To Item Number Planning Commission 5.2 Agenda Section Meeting Date Prepared by Public Hearings February 28, 2023 Zack Carlton, Community Development Director Item Description Reviewed by th Rinker Pipe – 1340 6 St. NW Chris Leeseberg, Senior Planner  Conditional Use Permit granting approval of a Reviewed by steel production building, Case No. CU 23-03 Action Requested Recommend, by motion, approval of the Conditional Use Permit with the following conditions to satisfy the standards set forth in Section 30-654: 1. Industrial operations outside of a structure are prohibited between 9:00 p.m. and 6:00 a.m. Monday through Saturday and on Sundays. 2. All exterior openings shall be closed when industrial operations occur within a building during the prohibited periods. 3. All vehicle back-up alarms shall be converted to a white-noise style by June 30, 2023. 4. The applicant shall submit a dust control plan for the operation prior to issuance of any building permits. 5. The applicant shall submit documentation demonstrating compliance with state and federal wellhead protection standards. Background/Discussion The subject site is located north of Highway 10 and generally west of Proctor Avenue and is approximately 55-acres in size. The site is zoned I-2 (Medium Industrial), which supports the proposed expansion/ change to the existing heavy industrial operation. The city’s earliest zoning map from 1980 zoned the property as I-2, and a concrete product manufacturing business operated on the site for decades prior to formal adoption of the city zoning map. The applicant proposes construction of a 39,000 square foot steel sided industrial building. The new building would be 41-feet tall (60-feet allowed) and will house industrial operations. Construction of the building will allow the applicant to move some of their operations indoors, reducing noise and facilitating year-round operation of some processes that currently shutdown during the colder months. The property abuts the railroad, the city public works facility, and an athletic complex to the north. Residential development has developed west and south of the site, and additional industrial operations are located to the east. The Elk River Vision A welcoming community with revolutionary and spirited resourcefulness, exceptional service, and community engagement that encourages and inspires prosperity. Updated: August 2020 Hours of Operation The applicant operates numerous shifts, with some beginning before 6:00 a.m. As this is a heavy manufacturing operation some of the work generates a significant amount of noise. Staff regularly receive calls from neighboring residential neighborhoods complaining of loud noises very early in the morning. While it is generally understood that the industrial operations of the applicant existed before the development of the residential areas, there is also an opportunity for some noise mitigation measures with construction of the new building. Building Materials The proposed building will be a steel sided structure similar to some of the existing buildings on site. The building location is generally behind large existing buildings and is largely screened from view along highway 10. Utilities There is a municipal well located less that 1,000 feet from the building site which is categorized by the Minnesota Department of Health as moderately vulnerable. Construction and operations in and around the building will need to follow federal and state wellhead protection requirements. Applicable Regulations In approving a Conditional Use Permit, the council may impose such specific conditions with regard to the development or operation of the proposed use as it considers necessary to satisfy the seven standards set forth in Section 30-654 and the requirements contained in this article and to promote compatibility with and minimize any potentially adverse effects upon adjacent properties, the neighborhood or the city. The issuance of a Conditional Use Permit can be ordered only if the use at the proposed location: 1. Will not endanger, injure or detrimentally affect the use and enjoyment of other property in the immediate vicinity or the public health, safety, morals, comfort, convenience or general welfare of the neighborhood or the city. As noted above, noise has become a reoccurring issue regarding the operation of the industrial use. For this reason, staff recommends two conditions. First, require industrial operations occurring outside of a building to conform to the city’s construction timing standards. Second, if industrial operations are to occur within the prohibited time, they should be within a building and all exterior openings must be closed. Additionally, drier summers the last few years have created concerns regarding wind-blown dust originating from the property. Especially dry and windy periods have generated concerns around the dust and what may be airborne along with the dust. To address these concerns, staff has included a condition that a dust control plan must be on file with the city prior to issuance of a building permit. The dust control plan should outline ongoing mitigation techniques and methods for addressing dust during especially dry and windy periods. 2. Will be consistent with the comprehensive plan. The property is guided for Industrial Uses and supports the growth and development of the Elk River business community. 3. Will not impede the normal and orderly development and improvement of surrounding vacant property. Surrounding properties are fully developed and staff has included conditions to address and mitigate impacts to adjacent, developed, areas. Staff does not see a need to impose specific conditions to satisfy this standard. 4. Will be served adequately by and will not adversely affect essential public facilities and services including streets, police and fire protection, drainage, refuse disposal, water and sewer systems, parks and schools; and will not, in particular, create traffic congestion or interference with traffic on adjacent and neighboring public thoroughfares. The property was developed for this type of use and has access to all city services. All access to this site occurs from the frontage road between the operation and Highway 10, or directly onto Highway 10. The use has been served adequately by and will not adversely affect essential public facilities and services including streets, police and fire protection, drainage, refuse disposal, water and sewer systems, parks and schools; and will not, in particular, create traffic congestion or interference with traffic on adjacent and neighboring public thoroughfares. Staff does not see a need to impose specific conditions to satisfy this standard. 5. Will not involve uses, activities, processes, materials, equipment and conditions of operation that will be detrimental to any persons or property because of excessive traffic, noise, smoke, fumes, glare, odors, dust or vibrations. Noise and dust have been a recent and re-occurring concern of this operation. Staff has met with business representatives in the past, and progress has been made. However, it is also appropriate to include additional conditions to further mitigate concerns from nearby neighborhoods. 6. Will not result in the destruction, loss or damage of a natural, scenic or historic feature of major importance. The site is fully developed and the new facility will be constructed in an area that is already covered by an impervious surface. Staff does not see a need to impose specific conditions to satisfy this standard. 7. Will fully comply with all other requirements of this Code, including any applicable requirements and standards for the issuance of a license or permit to establish and operate the proposed use in the city. The use will fully comply with all other requirements of this Code, including any applicable requirements and standards for the issuance of a license or permit to establish and operate the proposed use in the city. Staff does not see a need to impose specific conditions to satisfy this standard. If denial of such a permit should occur, it shall accompany recommendations or determinations by findings or a report stating how the proposed use does not comply with the standards set forth in Section 30-654. Financial Impact None Mission/Policy/Goal  Support the growth and development of the business community. Attachments  Location Map  Applicant’s Narrative  Site Plans  Architectural Plans/Elevations Rinker Materials, a division of the Quikrete Companies, is pleased to announce its intent to expand our indoor production capability at our Elk River facility through the construction of a new $8,400,000 production building. The need to expand indoors is largely due to the increase in state infrastructure investment creating more demand for our products. Moving the production of our pipe, manhole and box culvert production indoors will help meet the demand in Minnesota for these critical infrastructure components. The Elk River plant, located at 1340 6th Street SE, is the original site of Elk River Concrete Products also known as Cretex Concrete Products. The Cretex Companies began in 1917. One of the founding families was the Bailey family. The Cretex Companies are still a vital part of the local business community whose headquarters are located at 311 Lowell Ave. in Elk River. This plant became part of the Forterra Concrete Products group in 2016 and was later purchased by Quikrete/Rinker Materials in 2022. The expansion of our indoor production capability will be a positive impact to the Elk River area in a number of ways? * Reduction of seasonal layoffs of our plant employees. This will bring people into the Elk River plant for at least 3 additional months of each year which will positively impact the local economy. * Will significantly reduce noise from forklifts that currently operate outdoors. This facility will eliminate the use of at least 3 forklifts and one rubber tired gantry crane that are currently used in our outdoor operations. These machines will be replaced by overhead cranes in the new building. These cranes are much cleaner and quieter than the machines that are being replaced. * The new building will provide an enhanced visual appearance to the public. * A project of this size will have a positive impact on the local economy during the construction of this building. * Reduction of energy consumption for curing products outdoors. Currently we cure our products outdoors using live steam. Housing this production process will eliminate the need for use of live steam for curing. * The Quikrete Companies, are making a significant investment for the future making our plant a more attractive place to work which provides sustainable employment opportunities for decades to come. Our local management team and our employees are very excited about this project and are looking forward to your support as we move forward with opportunity for us and for our community. FLOOR PLAN GENERAL NOTES 1. SEE SHEET G001 FOR TYPICAL NOTES. 2. SEE SHEETS CL001 & CL002 FOR CODE DIAGRAM AND SUMMARY. 3. SEE SHEET A601 FOR WALL & PARTITION SCHEDULES & DOOR SCHEDULE. 4. SEE SHEET A602 FOR DOOR & WINDOW TYPES & ELEVATIONS. FLOOR PLAN KEYNOTES CONTROL JOINT WALL HUNG FE FE & FE CABINET MOP HOLDER/SHELF METAL THRESHOLD LINE OF OH DOOR ABOVE CONC FILLED PIPE BOLLARD - PAINTED (TYP) NOT USED LINE OF CANOPY ABOVE CONC STOOP - SEE STRUCT LIGHT - SEE ELEC LINE OF MEZZANINE ABOVE EQUIPMENT - SEE GA SHELVING BY OWNER PRE-FIN METAL DOWNSPOUT w/ CONC SPLASH BLOCK CONC SIDEWALK EYEWASH & SHOWER 1 1/2" OD DIA GALV METAL PIPE GUARDRAIL / HANDRAIL GALV METAL STAIR SYSTEM GALV METAL PIPE SLIDING GATE WHITE BOARD WD BENCH METAL LOCKERS PER DIV 10 WD BASE & UPPER CABINETS w/ PLAM COUNTER TOP & SIDE/BACK SPLASH 4" W PAINTED PARKING STRIPE ACCESSIBILITY SIGNAGE PAINTED ACCESSIBILITY SYMBOL STRIPED HANDICAP ACCESS ACCESSIBILITY CURB CUT HI-LO DRINKING FOUNTAIN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 370'-0"65'-8"4'-4"4'-4"35'-8"A A D G G 1 3 3 15 15 2 4 5 6 7 8 9 10 12 13 14 2'-0"23'-6"12'-6" 2'-0" 27'-4"27'-4"27'-4"27'-4"27'-4"27'-4"27'-4"27'-4"27'-4"27'-4"27'-4"27'-4"2'-0" 332'-0"70'-0"40'-0"20'-0"6'-0" 3'-4" 80'-0"20'-0"6'-0" 3'-4" 52'-8"20'-0"6'-0" 3'-4" 51'-0"7'-0"24'-0"8'-0"3'-4"5'-0"6'-4"30'-4"24'-0"4'-0" 3'-4" 50'-8"24'-0"4'-0" 3'-4" 50'-8"24'-0"4'-0" 3'-4" 50'-8"24'-0"4'-0" 3'-4" 51'-0" A301 1______________7'-0"24'-0"8'-0"3'-4"RAIL TRACK ABOVE RAIL TRACK ABOVE RAIL TRACK ABOVE RAIL TRACK ABOVE A201 2______________ A201 4______________ A201 3______________ A201 5______________ A301 2______________ 113.1 7.5T CRANE30T CRANE20T CRANE30T CRANE7.5T CRANE14'-4"40'-0"5'-8"30'-0"8'-8"60'-0"5'-8"3'-9"20'-0"4'-0" 3'-4" C.8 D.2 110'-0"38362.38 SF PROCESS 100 321.75 SF QC 101 106.69 SF RR 102 81.56 SF RR 103 30T CRANE7.5T CRANE763.559.9100 www.vaaeng.com2300 Berkshire Lane N, Suite 200 Plymouth, MN 55441 VAA, LLC DRAWING NO:PROJECT NO: DRAWING TITLE: CLIENT: PROJECT: SCALE: PRELIMINARY NOT FOR CONSTRUCTION Date Plotted:AS NOTED DATE: DRAWN: DESIGNED: ISSUE/REVISIONDATENO.BY CHECKED: APPROVED: NOTICE: THE DESIGN SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, DETAILS, DEVELOPMENTS, GRAPHICS AND MODELS THEREOF, ARE THE EXCLUSIVE PROPERTY OF VAA, LLC, AND CAN'T BE COPIED, DUPLICATED, REPRODUCED OR COMMERCIALLY EXPLOITED, IN WHOLE OR IN PART, NOR CAN ANY DERIVATIVE WORK BE MADE UNLESS EXPRESSLY AUTHORIZED IN WRITING BY VAA, LLC. COPYRIGHT VAA, LLC 2022 - ALL RIGHTS RESERVED. TRAVIS R. BECK, Architect, NCARB 41400 2/1/2023 2:59:35 PMA101 FIRST FLOOR PLAN ELK RIVER, MN RINKER MATERIALS ??/??/?? Author Designer Checker Approver NORTH 1/16" = 1'-0"A101 FIRST FLOOR PLAN1 30-TON I+IIDEMAG HYDRO CONDUITCORP. MAX CAP. 50TON. D773- 038WT. xxxxlbs. FABRICATEDBY: 7.5-TONDEMAG LOW EAVE EL 136'-10" EL 100'-0" T/ SLAB A D G EL 141'-5" HIGH EAVE A301 2______________ 110'-0" 70'-0"40'-0" C.8 D.2 1/2" 12" EL 100'-6" T/ CURB36'-4"40'-11"28'-0"28'-6"25'-11 5/8"1'-7 1/4"1'-3 1/8"EL 100'-0" T/ SLAB 1 15 EL 141'-5" HIGH EAVE 2 4 5 6 7 8 9 10 12 13 14 A301 1______________ 370'-0" 29'-4"27'-4"27'-4"54'-8"27'-4"27'-4"27'-4"27'-4"27'-4"27'-4"41'-10"25'-6" 113.1 EL 100'-6" T/ CURB 763.559.9100 www.vaaeng.com2300 Berkshire Lane N, Suite 200 Plymouth, MN 55441 VAA, LLC DRAWING NO:PROJECT NO: DRAWING TITLE: CLIENT: PROJECT: SCALE: PRELIMINARY NOT FOR CONSTRUCTION Date Plotted:AS NOTED DATE: DRAWN: DESIGNED: ISSUE/REVISIONDATENO.BY CHECKED: APPROVED: NOTICE: THE DESIGN SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, DETAILS, DEVELOPMENTS, GRAPHICS AND MODELS THEREOF, ARE THE EXCLUSIVE PROPERTY OF VAA, LLC, AND CAN'T BE COPIED, DUPLICATED, REPRODUCED OR COMMERCIALLY EXPLOITED, IN WHOLE OR IN PART, NOR CAN ANY DERIVATIVE WORK BE MADE UNLESS EXPRESSLY AUTHORIZED IN WRITING BY VAA, LLC. COPYRIGHT VAA, LLC 2022 - ALL RIGHTS RESERVED. TRAVIS R. BECK, Architect, NCARB 41400 2/1/2023 2:59:35 PMA301 BUILDING SECTIONS ELK RIVER, MN RINKER MATERIALS ??/??/?? Author Designer Checker Approver 1/8" = 1'-0"A301 BUILDING SECTION1 1/16" = 1'-0"A301 BUILDING SECTION2 423.4' TO EAST PROPERTY LINE424.7' TO EAST PROPERTY LINE45.0'40.0'45.0'1076.6' TO WEST PROPERTY LINE110.0'332.0'40.0'38.0'70.0'370.0'PROPOSED BUILDING ADDITIONAREA=39,180 S.F.FFE = 907.00115.9'79.3'±31.1'89.3'90.1'414.7' TO SOUTH PROPERTY LINE414.2' TO SOUTH PROPERTY LINE Quinn Ave. NW.Highway 10 West BoundUpland Ave. NW.8th St. NW.6TH ST NW423.4' TO EAST PROPERTY LINE424.7' TO EAST PROPERTY LINE45.0'40.0'45.0'1076.6' TO WEST PROPERTY LINE110.0'332.0'40.0'38.0'70.0'370.0'PROPOSED BUILDING ADDITION AREA=39,180 S.F. FFE = 907.00 115.9'79.3'±31.1'89.3'90.1'414.7' TO SOUTH PROPERTY LINE 414.2' TO SOUTH PROPERTY LINE 30'0SCALE: 1" = 30'SITE BASE SITE PLANC111:46 AM N:\Projects Current\17-0440.01 Rinker Materials Building Expansion\Civil\CAD Files\Rinker Site Plan.dwg2/2/2023 PROPOSED CONCRETE PAVEMENTPROPOSED BUILDINGPROPOSED CLASS 5 AGGREGATE / CRUSHED CONCRETECONCRETE CURB AND GUTTER - B612LEGEND:SITE PLAN NOTES:1.ALL CONCRETE RAMPS, SIDEWALKS AND ACCESSIBLE HANDICAPPEDPARKING STALLS TO CONFORM TO CURRENT A.D.A. REQUIREMENTS.2.CONTRACTOR SHALL FIELD VERIFY HORIZONTAL AND VERTICAL LOCATIONOF EXISTING UTILITIES PRIOR TO START OF CONSTRUCTION.3.CONTRACTOR SHALL INSTALL EROSION CONTROL MEASURES PRIOR TOTHE START OF CONSTRUCTION.4.CONSTRUCTION SHALL BE IN ACCORDANCE WITH APPLICABLE CITY,COUNTY AND STATE REGULATIONS.5.SITE SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE PLANSAPPROVED BY THE CITY.PROPOSED SIGNNDESCRIPTIONDATENO. REV FILE NO.: DWG FILE: CHECKED BY: DRAWN BY: DESIGN BY: DATE: SHEET NO.LAND SURVEYING CIVIL ENGINEERING ENVIRONMENTAL SERVICES 13076 FIRST STREET, BECKER, MN 55308-9322 TEL: 763-262-8822 FAX: 763-262-8844 BOGART, PEDERSON & ASSOCIATES, INC. RINKER MATERIALS ELK RIVER BUILDING EXPANSION CITY OF ELK RIVER, SHERBURNE COUNTY, MN 02/02/2023 17-0440.01 CJD CJD CJD NO T F O R C O N S T R U C T I O N120'0SCALE: 1" = 120' PROPOSED BUILDING ADDITIONFFE = 907.00906.50 TG905.01 TG905.04 TG906.00 TG906.25 TG905.30 TG904.52 TG906.12 TG905.78 TG904.00 TG905.54 TG905.58 TG905.37 TG904.49 TG904.00 TG5.9%4.2%5.4%7.5%1.9%0.5%0.5%1.6%0.8%0.5%0.8%0.5%0.5%5.3%6.4%5.3%5.0%4.5%4.4%1.3 %0.6%1.0%905905905 90590490690690690690690690690 6 907907907 907 905905 90 4 904 906906906906907 30'0SCALE: 1" = 30'GRADING GRADING PLANC211:46 AM N:\Projects Current\17-0440.01 Rinker Materials Building Expansion\Civil\CAD Files\Rinker Grading Plan.dwg2/2/2023 SFGRADING LIMITS AND PROPOSEDTEMPORARY SILT FENCETEMPORARY ROCK CONSTRUCTION ENTRANCEPROPOSED RIP RAP984NEW TOP-BACK OF CURB ELEVATIONNEW SIDEWALK ELEVATIONPROPOSED CONTOUR980.50 TCNEW FLOW LINE OF CURB ELEVATIONPROPOSED SLOPE980.50 FL980.50 SWNEW TOP OF GRAVEL ELEVATIONNEW TOP OF PAVEMENT ELEVATION980.50 TP980.50 TGEXISTING ELEVATION980.50 EXEROSION CONTROL BLANKET (PER DETAIL)NEW FINISHED GRADE ELEVATION980.50 FGEMERGENCY OVERFLOWE.O.F.TEMPORARY SEDIMENT FILTER- HIGH FLOWLEGEND:FIBER-LOG ROLLSGRADING GENERAL NOTES:1.THE CONTRACTOR SHALL NOTE ANY DISCREPANCIES BETWEEN EXISTING CONDITIONSIN THE FIELD REPRESENTED WITHIN THE PLANS AS SHOWN AND ALERT THE ENGINEERBEFORE BIDDING THE PROJECT AND BEGINNING CONSTRUCTION.2.CONTRACTOR SHALL LOCATE AND VERIFY ALL UTILITIES WHICH MAY AFFECT THISWORK AND NOTIFY THE OWNER OF ANY CHANGES. CONTACT LOCAL UTILITYCOMPANIES FOR EXACT LOCATIONS PRIOR TO BIDDING THE PROJECT ANDCOMMENCING WORK.3.CONTRACTOR SHALL TAKE NECESSARY PRECAUTIONS TO PREVENT SILT AND DEBRISRUN-OFF DURING GRADING OPERATIONS (I.E. SILT FENCE, STRAW BALES, ETC.).4.CONTRACTOR SHALL VERIFY CRITICAL ELEVATIONS TO ENSURE CONFORMANCE WITHGRADING PLAN, PARTICULARLY WITH EXISTING STRUCTURES AND/OR PAVEMENTS TOREMAIN. MEET EXISTING GRADES ALONG STREETS, PROPERTY LINES, AND DRIVEWAYENTRANCES. RESTORE ALL PAVEMENTS THAT REMAIN TO THEIR ORIGINAL IF NOTBETTER CONDITION. NOTIFY OWNER OF ANY CONFLICTS PRIOR TO BIDDING THEPROJECT.5.TURF ESTABLISHMENT AREAS SHALL RECEIVE MINIMUM OF 4" DEPTH AS MEASURED INPLACE OF TOPSOIL. TOPSOIL WILL BE FURNISHED AND INSTALLED BY THECONTRACTOR. ALL GRADED SLOPES GREATER THAN OR EQUAL TO 5:1 SHALL BEHYDROSEEDED, EROSION CONTROL BLANKETED, OR MULCHED TO HELP STABILIZE THESLOPES BY GENERAL CONTRACTOR.6.PROPOSED SPOT ELEVATIONS ARE TO THE TOP OF CURB UNLESS NOTED OTHERWISE.ELEVATION OF FLOW LINE IS 6" BELOW TOP OF CURB UNLESS OTHERWISE SHOWN.7.CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR DETERMINING QUANTITIES OF CUT,FILL AND WASTE MATERIALS TO BE HANDLED, AND FOR AMOUNT OF GRADING TO BEDONE IN ORDER TO COMPLETELY PERFORM ALL WORK INDICATED ON THE DRAWINGS.IMPORT SUITABLE MATERIAL AND EXPORT UNSUITABLE / EXCESS / WASTE MATERIAL ASREQUIRED. ALL COSTS ASSOCIATED WITH IMPORTING AND EXPORTING MATERIALSSHALL BE INCIDENTAL TO THE CONTRACT.8.IT IS INTENDED THAT EARTHWORK (CUT VS. FILL) BALANCE ON SITE. THE CONTRACTORSHALL SUBMIT THE QUANTITY OF MATERIAL AND AMOUNT OF ANTICIPATED GRADEADJUSTMENT FOR REVIEW BY THE ENGINEER A MINIMUM OF FOUR WEEKDAYS PRIORTO MAKING ADJUSTMENTS. ALL GRADE ADJUSTMENTS MUST BE APPROVED BY THEENGINEER. NO ADDITIONAL COMPENSATION WILL BE ALLOWED FOR WORK ASSOCIATEDWITH GRADING ADJUSTMENTS, INCLUDING, BUT NOT LIMITED TO, EARTHWORKOPERATIONS, STORM SEWER PIPING AND STRUCTURE ADJUSTMENTS, CONSTRUCTIONSURVEYING FOR ADJUSTING FEATURE LOCATIONS ACCORDINGLY, SILT FENCE, ETC.9.FAILURE OF TURF DEVELOPMENT: IN THE EVENT THE CONTRACTOR FAILS TO PROVIDEAN ACCEPTABLE TURF, THE CONTRACTOR SHALL RE-SEED OR RE-SOD ALL APPLICABLEAREAS, AT NO ADDITIONAL COST TO THE OWNER, TO THE SATISFACTION OF THEENGINEER.10.ANY MANHOLE, CATCH BASIN, STORM SEWER, SANITARY SEWER, DRAINTILE, OR OTHERPOTENTIAL SOURCE FOR CONTAMINATION SHALL BE INSTALLED AT LEAST 10 FEETHORIZONTALLY FROM ANY WATERMAIN PER MINNESOTA PLUMBING CODE. THISISOLATION DISTANCE SHALL BE MEASURED FROM THE OUTER EDGE OF THE PIPE TOTHE OUTER EDGE OF THE CONTAMINATION SOURCE (OUTER EDGE OF STRUCTURES ORPIPING OR SIMILAR)11.CONTRACTOR SHALL MAINTAIN DRAINAGE FROM EXISTING BUILDING AT ALL TIMES.PROVIDE TEMPORARY STORM SEWER (INCLUDING, BUT NOT LIMITED TO, CATCH BASINS,MANHOLES, PIPING, ETC.) AS REQUIRED. EXISTING STORM SEWER SHALL NOT BEREMOVED UNTIL TEMPORARY OR PERMANENT STORM SEWER IS INSTALLED ANDFUNCTIONAL. COORDINATE ALL REMOVALS WITH APPROPRIATE TRADES (SITE UTILITYCONTRACTOR, MECHANICAL CONTRACTOR, ETC.) AS REQUIRED.NDESCRIPTIONDATENO. REV FILE NO.: DWG FILE: CHECKED BY: DRAWN BY: DESIGN BY: DATE: SHEET NO.LAND SURVEYING CIVIL ENGINEERING ENVIRONMENTAL SERVICES 13076 FIRST STREET, BECKER, MN 55308-9322 TEL: 763-262-8822 FAX: 763-262-8844 BOGART, PEDERSON & ASSOCIATES, INC. RINKER MATERIALS ELK RIVER BUILDING EXPANSION CITY OF ELK RIVER, SHERBURNE COUNTY, MN 02/02/2023 17-0440.01 CJD CJD CJD NO T F O R C O N S T R U C T I O N RINKER MATERIALS PREPARED BY Project Manager Checked By Approved By LOCATION SKETCH INDEX OF SHEETS SCALE 0 STEVE POETHKE 1 - TITLE SHEET 1 MILE BUILDING EXPANSION PREPARED BY Project Manager Checked By Approved By LOCATION SKETCH INDEX OF SHEETS SCALE 0 LOCATION 1 - TITLE SHEET 2 - EXISTING SITE 3 - PROPOSED SITE 2 MILE ELK RIVER, MINNESOTA DATENO.BY REVISIONS COOPER 2600 COLLEGE DRIVE, P.O. BOX 230PROJECT TELEPHONE (715) 234-7008 FAX (715) 234-1025 SHEET MANAGER APPROVED BY CHECKED BY ENGINEERING RICE LAKE, WISCONSIN 54868-0230G:\2022-proj\22445200\C3D\sheets\SitePlan.dwgPLOT DATE: Nov 15, 2022 - 12:49pmDRAWN BY ISSUE DATE CEC PROJECT NO.RINKER MATERIALS *** *** STEVE POETHKE 11-16-22 BSW 22445200 1 ***** TITLE BUILDING ADDITION SHERBURNE COUNTY, MINNESOTA E E E EE E ESANSANSANSANSANSANSANSANWWWWWGGG90490 6 9 0 6 908904 906 905 904 906906906DATENO.BY REVISIONS COOPER 2600 COLLEGE DRIVE, P.O. BOX 230PROJECT TELEPHONE (715) 234-7008 FAX (715) 234-1025 SHEET MANAGER APPROVED BY CHECKED BY ENGINEERING RICE LAKE, WISCONSIN 54868-0230G:\2022-proj\22445200\C3D\sheets\SitePlan.dwgPLOT DATE: Nov 16, 2022 - 10:53amDRAWN BY ISSUE DATE CEC PROJECT NO.RINKER MATERIALSSTEVE POETHKE 11/16/22 BSW 22445200 2 OF 3ELK RIVER, MN EXISTING SITE CONCRETE PIPE DIVISION WATER GAS UNDERGROUND STEAM TUNNEL UNDERGROUND STEAM TUNNEL EXISTING CONCRETE SLAB EXISTING PRESTRESS BUILDING HAUL ROAD EXISTING CATCH BASIN ELECTRICAL GRAPHIC SCALE 0 505025 100 EXISTING BUILDING ELECTRICAL SANITARY HAUL ROADHAUL ROAD HAUL ROADHAUL ROAD HAUL ROAD HAUL ROAD HAUL ROAD HAUL ROADHAUL ROAD HAUL ROAD HA U L R O A D UNDERGROUND STEAM PIPE EXISTING CATCH BASIN SANITARY ELECTRICAL EXISTING STEPS SANITARY STORMWATER DRAINS WEST E E E EE E ESANSANSANSANSANSANSANSANWWWWWGGG90490 6 9 0 6 908904 906 905 904 906906906DATENO.BY REVISIONS COOPER 2600 COLLEGE DRIVE, P.O. BOX 230PROJECT TELEPHONE (715) 234-7008 FAX (715) 234-1025 SHEET MANAGER APPROVED BY CHECKED BY ENGINEERING RICE LAKE, WISCONSIN 54868-0230G:\2022-proj\22445200\C3D\sheets\SitePlan.dwgPLOT DATE: Feb 01, 2023 - 09:33amDRAWN BY ISSUE DATE CEC PROJECT NO.RINKER MATERIALSSTEVE POETHKE 02/01/23 BSW 22445200 3 OF 3ELK RIVER, MN EXISTING SITE CONCRETE PIPE DIVISION WATER GAS UNDERGROUND STEAM TUNNEL UNDERGROUND STEAM TUNNEL EXISTING CONCRETE SLAB EXISTING PRESTRESS BUILDING HAUL ROAD EXISTING CATCH BASIN ELECTRICAL GRAPHIC SCALE 0 505025 100 EXISTING BUILDING ELECTRICAL SANITARY HAUL ROADHAUL ROAD HAUL ROADHAUL ROAD HAUL ROAD HAUL ROAD HAUL ROAD HAUL ROADHAUL ROAD HAUL ROAD HA U L R O A D UNDERGROUND STEAM PIPE EXISTING CATCH BASIN SANITARY ELECTRICAL EXISTING STEPS SANITARY PROPOSED CAGING BUILDING 6" SLAB ELEV: 906.5 PROPOSED WET CAST BUILDING 9" SLAB. ELEV: 906.5 370' 110' 40' STORMWATER DRAINS WEST 50' 45' 70' 40'