Loading...
Board of Adjustments Packet for February 25, 2025 Board of Adjustments Regular Meeting Agenda Tuesday, February 25, 2025 6:30 PM Elk River City Hall ▪ Regular meeting in Council Chambers 1. CALL MEETING TO ORDER 2. PLEDGE OF ALLEGIANCE 3. CONSIDER AGENDA 4. CONSIDER MINUTES 4.1 Draft Minutes - July 23, 2024 5. PUBLIC HEARINGS An opportunity for the public to express their opinions and raise questions pertaining to the agenda item. All comments become part of the official public record. For this reason, all comments must be made at the podium so they can be heard and recorded. Comments may also be provided in writing. There will not be deliberations, discussions, or answers to questions until the hearing is closed. It is important to be courteous and allow each presenter to comment before adding additional testimony. 5.1 Variance: Front Yard Setback, 11848 193rd Lane NW, Kelly and Craig Swanson 6. MOTION TO ADJOURN REGULAR MEETING Page 1 of 14 DRAFTPage 2 of 14 DRAFTPage 3 of 14 DRAFTPage 4 of 14 DRAFTPage 5 of 14 The Elk River Vision A welcoming community with revolutionary and spirited resourcefulness, exceptional service, and community engagement that encourages and inspires prosperity Request for Action To Board of Adjustments Item Number 5.1 Meeting Date February 25, 2025 Prepared By Chris Leeseberg, Senior Planner Item Description Variance: Front Yard Setback, 11848 193rd Lane NW, Kelly and Craig Swanson Reviewed by Zack Carlton Action Requested Approve, by motion, the front yard setback variance of 10-feet for the following reasons: 1. The general purpose and intent of the ordinance are met. 2. The property has a land use of residential and the use is consistent with the Comprehensive Plan. 3. The proposed use is reasonable and is otherwise permitted in the zoning ordinance. 4. The plight of the petitioner is due to circumstances unique to the property not a consequence of the petitioner’s own action or inaction. 5. The variance will not alter the essential character of the locality. Background/Discussion The applicant is proposing to construct a 31’ x 32’ detached garage (accessory structure) and is requesting a 10-foot variance to allow the structure to be closer to the front property line. The 1.18-acre property, zoned R1-C (Single-Family Residential), is subject to a 30-foot setback requirement for accessory structures. The requested variance would accommodate the garage while maintaining the residential character and adhering to the overall intent of the zoning ordinance. Applicable Regulation (The applicant’s responses are italicized with staff notes afterwards.) Variances may be granted when the petitioner establishes that the variance satisfies all five of the criteria described below. The variance is: 1. Is in harmony with the general purpose and intent of the ordinance, and We're proposing a variance from the standard 30-foot setback requirement for our new 31x32 ft 936 sq ft detached garage. It also includes a 120 sq ft patio. Page 6 of 14 The intent of the city's setback requirement is to maintain a consistent appearance within neighborhoods. Our home is on a cul-de-sac and has large expansive areas between neighboring dwellings. This currently allows for a pleasant view regardless of uniformity. The purpose of front yard setbacks is to prevent buildings from being constructed too close to the street, thereby maintaining a visually cohesive and attractive streetscape. Since the property is located at the end of a cul-de-sac, any deviation from this uniformity may not be readily apparent. The request aligns with the general purpose and intent of the regulation. 2. Is consistent with the City of Elk River comprehensive plan. We're committed to ensuring the garage is aesthetically pleasing and consistent with the neighborhood's character, including additional boulder landscaping to integrate it into the surroundings. The property is guided as Traditional Single-Family Residential, where houses and accessory structures are anticipated. The proposal aligns with the goals of the comprehensive plan. Variances may be granted when the petitioner establishes that there are practical difficulties in complying with the zoning ordinance. Practical difficulties means that: 3. The petitioner proposes to use the property in a reasonable manner not permitted by the zoning ordinance; The front most post to the 120 sq ft patio (the lean-to) on the street side of the garage will be positioned 20 feet from the property line (10 ft inside the set back), which allows us to protect the environment and save on significant grading costs. It should be noted that the proposed front left corner of the 936 sq ft structure, not the lean-to, will be no more than 3 feet into the set back line. The petitioner is requesting to build an accessory structure beyond the required setback to preserve several mature trees on the property and minimize the necessary grading. This proposal represents a reasonable use of the property that is not permitted under the current zoning ordinance. 4. The plight of the petitioner is due to circumstances unique to the property not a consequence of the petition's own action or inaction; and The current proposed location for the garage requires minimal grading of an existing hill, preserving the natural topography and existing mature trees. Meeting the standard setback would necessitate extensive hill grading leading to significant increased costs, engineered boulder retaining walls and the unnecessary removal of numerous trees, which would significantly impact the natural beauty and ecosystem of the property. The property’s unique characteristics include steep grades and mature trees. Meeting the setback requirements would necessitate significant grading and the removal of several trees. 5. The variance, if granted, will not alter the essential character of the locality. Granting this variance is not only a cost-effective solution but also an environmentally responsible decision. Our home is situated on a cul-de-sac with homes that are not closely adjacent to one another, which means our garage will not disrupt the visual harmony or proximity that the setback rule intends to preserve. It supports our commitment to sustainability and community values. We're dedicated to complying with all other zoning and building codes to enhance Page 7 of 14 our property's value and maintain the integrity of the neighborhood. Because the property is situated at the end of a cul-de-sac, any deviation from the setback requirements would not impact the neighborhood’s character. Granting the variance will not alter the essential character of the area. Financial Impact None Mission/Policy/Goal Work with citizens to achieve goals. Attachments 1. Location Map 2. Site and Building Plans 3. Images Page 8 of 14 Page 9 of 14 4040RS 81701008010080 4040RS28683'-6"10'4'10'3'-6" 15'-6"15'-6" 31'32'14'15'-8"2'-4"30'-1 1/8" x 31'-1 1/8" 936 sq ft Attic Trusses 24" O.C. over Design and Engineering by Supplier NARROW WALL BRACING DETAIL * AP R602.10 Wall Bracing Requirement Code Attic Trusses 24" O.C. over Design and Engineering by Supplier Extend Top Chord for Porch Roof 2-1 3/4"x 11 7/8" LVL Header * 2x4 Studs 16" O.C. entire Perimeter of Garage * Corner Bracing or Rigid Sheathing on each side of Overhead door and 4' back from each corner * Headers over all Exterior Windows and Doors to be 2-2x10 unless Otherwise Noted on Plan Garage 2-1 3/4"x 11 7/8" LVL Header 9'-4" Minimum Ceiling Height 2-1 3/4"x 9 1/2" LVL HeaderPage 1Main Floor Scale 1/4"=1'-0" Craig & Kelly 1-13-25 Page 10 of 14 1'-4"9'-3"31' 2'1'-4 1/2"8'9'-4 1/2"1'1'9'-9"22'32'29'-0" x 30'-0" 870 sq ft Unexcavated Fill to Slab Conc Curb Cut 3" Larger than Garage Doorfor (1) 2x4 Treated Header Bearing each sideOverhead Gar Dr Height Garage Wall Height * 2x6 Treated sill Plate set on Sill Sealer * Anchor Bolts or Straps 12" from each corner 60" O.C. entire Perimeter * 4" Poured Conc Floating Slab Foundation with Thickened Perimeter Footing 4" Conc Slab 4" Class 5 Compacted Fill (2) #4 Rebar Thickened Slab Perimeter 12" Conc Footing or Thickened Slab for Post and Beam Support le Overhang ve Overhang h Scale: 1/8"=1'-0" Right-North-Hill ElevationLeft-South-Street Elevation Rear-West Elevation Scale 1/4"=1'-0" Foundation Plan Page 2 Craig & Kelly 1-13-25 Page 11 of 14 4040RS 4040R S 2868 3 '-6 "1 5 '-6 "1 5 '-6 "3 1 '14' 1 5'-8" 2'-4"30'-1 1/8" x 31 '-1 1/8 " 9 3 6 sq ftA ttic T r us s e s 2 4 " O .C . o v e r D e s ig n a n d E n g in e e rin g b y S u p p lie rOW W A L L B R A C IN G D E T A IL 2 .10 W a ll B ra c in g R e qu ire m e n t C o d eAttic T ru ss e s 2 4 " O .C . o v e rD e s ig n a nd E n g in e e r in g b y S u p p lie r E xte nd T o p Ch o rd fo r P o rc h R o o f O .C . e n tir e P e rime te r o f G a ra g e R ig id S h ea th in g o n ea c h s id e o fb a c k fr om e a c h c or n e r W in d ow s a n d D o o r s to b e o n P la n G a rag e9'-4" M inim um C eiling H eightPlot Plan Scale: 1/4"=1'-0" Craig & Kelly 1-13-25 Page 3 * Shaded Square indicates Proposed Position of 31'x32' Detached Garage with 6' x20' Porch in South East Corner * South East Corner Post of Porch is 10' into Easement Double Tier Boulder wall to be Built on UpHill side (North) of Proposed Garage * Proposed Boulder Wall * Exact Specs and Install by Landscaper Page 12 of 14 Page 13 of 14 Page 14 of 14