Loading...
Miske8_4INFILTRATION BASIN 9 BTM:922 (20,800 SF) OUT: 924.0 HWL: 925.4 EOF: 928.5 OUTBOT HWL INFILTRATION BASIN 15 BTM: 925.0 (16,000 SF) HWL: 928.3 EOF:930.5 BOT HWL 243+0 0 244+0 0 245+00 246+00 247+00 248+00 249+00 250+00 251+00 252+0 0 253+ 0 0 254+00255+008+ 0 0 9 + 0 0 10+0011+009 4 9 . 8 94 7 . 9 9 4 5 . 7 941.093 6 .1 94 8 . 7 94 7 . 2 94 3 .5938.6927.70LP0+001+002+003+004+005+00935.5933.5931.5929.5927.8928.0934.5932.5930.5928.5927.8EX.S&W EX.S&W EX.S&W EX.S&W 948.09 HP 922.0 926.5 928.7 930.7 932.7 934.7 936.7 938.7 940.7 942.7 944.7 946.7948.1919.5 924.5 927.7 929.7 931.7 933.7 935.7 937.7 939.7 941.7 943.7 945.7947.7947.6WBP WBP WBP WBP NW TWIN LAKES PARKWAY TWIN LAKES PARKWAY IVANHOESTREETIVANHOESTREET927.43 HP 188THAVENWDEVELOPMENTFUTUREEX SMH-5A CBOX: 935.8 CBOX: 938.4 CBOX: 941.5 CBOX: 946.2 CBOX: 947.0 CBOX: 945.6 CBOX: 942.1 CBOX: 947.9 CBOX: 946.2 CBOX: 944.8 CBOX: 943.2 CBOX: 941.7 CBOX: 940.2 CBOX: 938.6CBOX: 937.0CBOX: 935.6 CBOX: 935.0 CBOX: 936.3 CBOX: 937.5 CBOX: 938.7 CBOX: 939.9 CBOX: 941.1 CBOX: 942.3 CBOX: 943.3 CBOX: 945.5 CBOX: 931.4 CBOX: 930.1 CBOX: 928.2 CBOX: 927.7 CBOX: 925.7 CBOX: 929.6 SERV: 0+90 915.7 SERV: 0+23 917.5 1' RISER SERV: 0+07 919.9 4'-RISER SERV: 0+88 921.2 5'-RISER SERV: 0+29 914.5 7'-RISER SERV: 0+37 935.8 17'-RISER SERV: 0+18 933.1 14'-RISER SERV: 0+71 930.3 11'-RISER SERV: 2+55 922.1 2'-RISER SERV: 2+11 924.1 4'-RISER SERV: 1+50 926.9 7'-RISER SERV: 0+87 930.5 11'-RISER SERV: 0+50 934.8 16'-RISER SERV: 0+69 918.8 2'-RISER CB 2403 FES 2400 FES 2500 STMH 2501 CBMH 2502 CBMH 2503 CBMH 2504 CB 2505 FES 4202 FES 4200 42 41 40 EX SMH-7 EX SMH-6 EX SMH-8 SMH 84 SMH 83 SMH 82 8" G.V. RELOCATED HYDRANT 6" G.V. 8" x 6" TEE RELOCATE HYDRANT to STA 250+75 6" G.V. 8" x 6" TEE 11.25° BEND 11.25° BEND 11.25° BEND 22.5° BEND 22.5° BENDS RELOCATE EX HYDRANT TO STA 240+75 8" x 6" TEE 6" G.V. EX. G.V. EX HYDRANT 12" x 6" TEE 6" G.V. 12" G.V. EX 12" x 12" TEE 12" G.V. BOT HWL 8+ 0 0 9 + 0 0 10+0011+00CBOX: 944.5 EX. SAN. SERVICE EX. SAN. SERVICE EX. SAN. SERVICE EX. SAN. SERVICEEX. SAN. SERVICE EX. SAN. SERVICE EX. SAN. SERVICE EX. SAN. SERVICE EX. SAN. SERVICE EX. SAN. SERVICE EX. SAN. SERVICE EX. SAN. SERVICE EX. SAN. SERVICE EX. SAN. SERVICE EX. SAN. SERVICE EX. SAN. SERVICE EX. SAN. SERVICE EX. SAN. SERVICE EX. SAN. SERVICE 12"x12" TEE 12"x8" TEE 8" G.V. CCONNECT TO EXISTING 12" WM EX 12" PLUG CBMH 2402 CBMH 2401 SMH 43-B43-A BUILD MH OVER EXIST. 8" PVC. SDR 26 STUB LOWER WATER SERVICE UNDER STORM SEWER AND INSULATE TO AVOID CONFLICT ADJUST EXISTING SANITARY MANHOLE AND CASTING AS NECESSARY LOWER EXISTING SANITARY MANHOLE CASTING APPROX. 0.1 FEET (CONTRACTOR TO FIELD VERIFY) ADJUST EXISTING SANITARY MANHOLE AND CASTING AS NECESSARY (TYP.) ADJUST EXISTING SANITARY MANHOLE AND CASTING AS NECESSARY (TYP.) ADJUST EXISTING G.V. AS NECESSARY CBOX: 917.8 OUTLOT C OUTLOT D 7 8 9 10 11 12 13 6 7 8 9 10 11 12 13 15 14 15 16 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 OUTLOT G BLOCK 2 BLOCK 3 BLOCK 4 #468 #469 #470 #471 #472#473 #474 #475 #476 #477 #478 #479 #489 #490 #491 #492 #493 #494 #495 #496 #497 #498 #499 #500 #466 #467 #262 #263 #264 #265 #266 #263A #501 #502 #503 #505 CBOX: 928.8 CBOX: 929.2 CBOX: 930.9 SERV: 0+10 918.8 1'-RISER SERV: 0+35 919.2 4'-RISER SERV: 1+01 920.9 6'-RISER #488 #487 #486 INSULATE WATER MAIN CROSSING AT CB INSULATE WATER MAIN CROSSING AT CB REMOVE EXIST. 12" WATERMAIN REMOVE EXIST. 6" WM & GV (FIELD VERIFY) HYDRANT 6" G.V. 12" x 6" TEE CONNECT TO EXISTING 8" WM 42' TNH=943.50 TNH=929.71 57' 60' 51' 52' 90' 47' 100' 63'105' 32' 40' 80' 103'56'50' 40' 63' 123' 47' 33' 52'34' 59' 110' 54' 59' 172' 107' 114' 52' 150' 77' 88' 33'60' 50'57' 64' 56'98' 88' 33' 62' 48'52'94'93' 55' 38' 22' 38' 13' 118' 53' 71' 42' 27' TWIN LAKES PARKWAY 880 890 900 910 920 930 940 950 960 880 890 900 910 920 930 940 950 960 243+50919.0924.51244+00922.5926.51244+50927.7927.72245+00931.7928.72245+50934.4929.72246+00936.7930.72246+50935.4931.72247+00932.7932.72247+50935.2933.72248+00938.6934.72248+50941.1935.72249+00941.9936.72249+50943.7937.72250+00947.7938.72250+50951.3939.72251+00952.1940.72251+50945.5941.72252+00939.3942.72252+50937.2943.72253+00937.2944.72253+50936.6945.72254+00934.8946.72254+50934.8947.69255+00935.7948.092.00% SMH 82 RE=929.7 IE=913.6 W IE=913.5 E BUILD=16.2' SMH 83 RE=927.7 IE=914.1 SW IE=914.0 E BUILD=13.7'SMH 84 RE=924.5 IE=914.5 NE BUILD=10.0' EX SMH-7 RE=932.4 IE=912.9 E IE=905.4 N IE=905.4 S BUILD=27.0' 100 LF - 8" PVC SDR 35 @ 0.40%100 LF - 8" PVC SDR 35 @ 0.40%139 LF - 8" PVC SDR 26 @ 0.40% 40 RE=936.9 IE=913.5 E IE=913.5 W BUILD=23.4' 41 RE=940.7 IE=914.3 NE IE=914.3 W BUILD=26.5' 42 RE=944.7 IE=915.2 NE IE=915.2 SW BUILD=29.6' 43 RE=948.1 IE=916.0 SE IE=916.5 NE IE=916.0 SW BUILD=32.2' 210 LF - 8" PVC @ 0.32% 199 LF - 8" PVC @ 0.36% 199 LF - 8" PVC @ 0.45% 205 LF - 8" Ductile Iron Pipe @ 0.39% STORM X-ING STORM X-ING 0+88 5'-R.0+07 4'-R.0+692'-R.12" DIP CL 52 WATERMA I N 12" DIP CL 52 WATERMA I N PROPOSED GRADE EXISTING GRADE 8" DIP CL 52 WATERM A I N 8" DIP CL 52 WATERM A I N 8" DIP CL 52 WATERM A I N +41 EX. FLUSHING HYD.EXIST. FLUSHING HYD. RELOCATE TO STA: 250+75 +75 HYD.EXIST 8" DIP MAINT. 7.5' MIN. COVER OVER WATERMAIN MAINT. 7.5' MIN. COVER OVER WATERMAIN RELOCATED HYD. 6" GV 12 LF 6" DIP (SEE CITY STD. PLATE 3402, SHEET C9.01) CONNECT TO EXIST. MH IE=912.9 INSIDE DROP SEE DETAIL 4002/C9.01A INSULATE W/ 3" MIN. FOAMBOARD LOWER WM MIN. 18" UNDER STORM STRUCTURE TO AVOID CONFLICT0+231'-R.1+01 6'-R.0+354'-R.0+101'-R.INSULATE W/ 3" MIN. FOAMBOARD 12" DIP CL 52 WATERM A I N HYD. 6" GV (SEE CITY STD. PLATE 3402, SHEET C9.01)+20 HYD.CONNECT TO EXISTING 8" WM 924.10 914.70 9.4 927.46 914.20 914.20 13.3 929.78 913.62 913.62 16.2 102 0.49 102 0.57 141 0.51 SCALE IN FEET 0 10050 NORTH Dec 18, 2023 - 11:05am - User:tkeeley L:\PROJECTS\20460.06\CAD\Record Plan\Miske Meadows 8th Addition Record Plans\20460.80 - C6-RP-UTILITY.dwg C6.03 UTILITY PLAN - TWIN LAKES PARKWAY Project Location Date Submittal / RevisionNo. Certification Sheet Title Summary Revision History Sheet No.Revision Project No. By Designed:Drawn: Approved:Initial Issue: Phase: Client LGI HOMES- Minnesota, LLC 2850 CUTTERS GROVE AVENUE SUITE 207 ANOKA, MN 55303 MISKE MEADOWS EIGHTH ADDITION ELK RIVER, MN JEB TPK/CE/JLB ETL CONSTRUCTION 06/30/2022 20460.80 I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly licensed professional ENGINEER under the laws of the state of Minnesota. If applicable, contact us for a wet signed copy of this plan which is available upon request at Sambatek's, Minnetonka, MN office. Registration No.Date:06/30/202250475 Eric T. Luth 06/30/2022 CONSTRUCTION DOCUMENTS 6/08/2023 RECORD PLANS SCALE HORIZONTAL: 1"=50' VERTICAL: 1"=10' LEGEND EASEMENT WATERMAIN SANITARY SEWER EXISTINGPROPOSED STORM SEWER CURB & GUTTER D S S SANITARY SERVICE WATER SERVICE PROPERTY LINE D S S FUTURE 8'x8'x4" INSULATION PLANK PHASE LINE THE SUBSURFACE UTILITY INFORMATION SHOWN ON THESE PLANS IS A UTILITY QUALITY LEVEL D. THIS QUALITY LEVEL WAS DETERMINED ACCORDING TO THE GUIDELINES OF ASCE/CI 38-02, TITLED "STANDARD GUIDELINES FOR THE COLLECTION AND DEPICTION OF EXISTING SUBSURFACE UTILITY DATA." THE CONTRACTOR AND/ORSUBCONTRACTORS SHALL DETERMINE THE EXACT LOCATION OF ALL EXISTING UTILITIES BEFORE COMMENCINGWORK, BY CONTACTING THE NOTIFICATION CENTER (GOPHER STATE ONE FOR MINNESOTA). THE CONTRACTOR AND/OR SUBCONTRACTOR AGREE TO BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES, WHICH MIGHT BEOCCASIONED BY HIS OR HER FAILURE TO EXACTLY LOCATE AND PRESERVE ANY AND ALL UTILITIES (UNDERGROUND AND OVERHEAD). IF THE CONTRACTOR ENCOUNTERS ANY DRAIN TILE WITHIN THE SITE, HE OR SHE SHALL NOTIFY THE ENGINEER WITHTHE LOCATION, SIZE, INVERT AND IF THE TILE LINE IS ACTIVE. NO DRAIN TILE SHALL BE BACKFILLED WITHOUTAPPROVAL FROM THE PROJECT ENGINEER.IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES WHICH CONFLICT WITHTHE PROPOSED IMPROVEMENTS SHOWN ON THE PLANS.SEE SHEET C6.02SEE SHEET C6.02CONTRACTOR SHALL COORDINATE WITH ERMU TO DETERMINE THE LOCATION OF ANY EXISTING WATERMAIN VALVE BOXES WITHIN THE PROJECT THAT ARE CURRENTLY BURIED OR COVERED BY BLACKTOP. CONTRACTOR SHALL WORK TO EXPOSE AND ADJUST AS NECESSARY TO MAKE THEM OPERABLE FOR ERMU SAMBATEK, INC. 12/18/2023 C.W.HOULE, INC. C.W.HOULE, INC. COMPLETED BY: DATE OF COMPLETION: STREET/UTILITY CONTRACTOR: GRADING CONTRACTOR: RECORD PLAN NOTES THESE RECORD PLANS HAVE BEEN PREPARED, IN PART, BASED ON INFORMATION COMPILED AND FURNISHED BY OTHERS. THE ENGINEER HAS NOT VERIFIED THE ACCURACY AND/OR COMPLETENESS OF THE INFORMATION PROVIDED AND SHALL NOT BE RESPONSIBLE FOR ANY ERRORS OR OMISSIONS WHICH HAVE BEEN INCORPORATED INTO THESE RECORD PLANS AS A RESULT.