Loading...
Miske8_7231+00 232+00 233+ 0 0 234+ 0 0 235+0 0 236+00 237+00 238+00 239+00 240+00 241+00 242+00 243+ 0 0 244+0 0 915.58 HP 911.6 3 LP 912.95 LP 914.9 914.0 913. 0 912. 0 911.7 913.4 915.3 915.1 914.1 913.0 913.7 917.0 922.0 926.5 914.4 913.5 912. 5 911. 7 912.4 914.4 915.6 914.6 913.5 913.0 915.0 919.5 924.5 TWIN TWIN LAKES PARKWAY #478 #479 #480#481 #482#483#484#485 927.43 OUT BOT HWL OUT BOT HWL INFILTRATION BASIN 13 BTM: 907.5 (2,900 SF) OUT:908.5 HWL:909.9 EOF:910.0 INFILTRATION BASIN 14 BTM:907.0 (3,350 SF) OUT:908.0 HWL:908.8 EOF:909.3 FES 4001 FES 4000 CB 2703 CBMH 2702 STMH 2701 FES 2700 FES 3101 FES 3100 FES 2600 CBMH 2601 CB 2602 ADJUST EXISTING STORM MANHOLE AS NECESSARY. SWAP OUT SOLID GRATE FOR R-3067V. CASTING SHALL BE IN CURB FLOWLINE. ADJUST EXISTING CATCH BASIN AS NECESSARY. CASTING SHALL BE IN CURB FLOWLINE. ADJUST EXISTING CATCH BASIN AS NECESSARY. CASTING SHALL BE IN CURB FLOWLINE. TWO FUTURE 65"x40" ARCH PIPE X-ING'S BY OTHERS ADJUST EXISTING CATCH BASIN AS NECESSARY. CASTING SHALL BE IN CURB FLOWLINE. 1 OUTLOT B 2 3 4 5 6 12 13 OUTLOT A BLOCK 1 65"x40" ARCH PIPE FES IE: 900.6 65"x40" ARCH PIPE FES IE: 900.2 890 900 910 920 930 940 890 900 910 920 930 940 PROPOSED GRADE STMH 2701 (48")RE=910.50BLD=3.3'IE=907.26 SIE=907.26 E72 LF - 18" RCP @ 0.35% FES 2700FLEXAMAT OR APPROVED EQUALIE=907.0 W (18" )CB 2703 (24"X36")RE=911.32BLD=3.4'IE=907.90 N31 LF - 15" RCP @ 0.30%CBMH 2702 (48")W/ SAFL BAFFLERE=911.35BLD=7.1'IE=904.26 (3.5' SUMP)IE=907.81 SIE=907.81 N156 LF - 18" RCP @ 0.35% 12" WM XING 910.842.7908.18910.846.5908.02908.02910.343.2907.12907.12906.9232 0.50 0.58 0.30 155 66904.32880 890 900 910 920 930 940 880 890 900 910 920 930 940 47 LF - 24" RCP @ 0.50% FES 4000FLEXAMAT OR APPROVED EQUALIE=907.8 SW (24" ) FES 4001IE=908.0 NE (24" )PROPOSED GRADE 908.20908.100.28 36 880 890 900 910 920 930 940 880 890 900 910 920 930 940 27 LF - 24" RCP @ 0.50% FES 3101IE=908.5 N (24" ) FES 3100FLEXAMAT OR APPROVED EQUALIE=908.4 S (24" )PROPOSED GRADE 908.66908.5328 0.46 880 890 900 910 920 930 940 880 890 900 910 920 930 940 PROPOSED GRADE CB 2602 (24"X36")RE=921.72BLD=3.5'IE=918.20 NW31 LF - 15" RCP @ 2.00%CBMH 2601 (48")W/ SAFLE BAFFLERE=921.72BLD=14.4'IE=907.30 (3.5' SUMP)IE=917.57 SEIE=910.80 W115 LF - 18" RCP @ 2.00% FES 2600FLEXAMAT OR APPROVED EQUALIE=908.5 E (18" )908.65921.5614.9917.11910.52921.423.6917.78112 1.67 32 2.09906.67SCALE IN FEET 0 10050 NORTH Dec 18, 2023 - 9:38am - User:tkeeley L:\PROJECTS\20460.06\CAD\Record Plan\Miske Meadows 8th Addition Record Plans\20460.80 - C7-RP-STORM.dwg C7.01 STORM SEWER Project Location Date Submittal / RevisionNo. Certification Sheet Title Summary Revision History Sheet No.Revision Project No. By Designed:Drawn: Approved:Initial Issue: Phase: Client LGI HOMES- Minnesota, LLC 2850 CUTTERS GROVE AVENUE SUITE 207 ANOKA, MN 55303 MISKE MEADOWS EIGHTH ADDITION ELK RIVER, MN JEB TPK/CE/JLB ETL CONSTRUCTION 06/30/2022 20460.80 I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly licensed professional ENGINEER under the laws of the state of Minnesota. If applicable, contact us for a wet signed copy of this plan which is available upon request at Sambatek's, Minnetonka, MN office. Registration No.Date:06/30/202250475 Eric T. Luth 06/30/2022 CONSTRUCTION DOCUMENTS 6/08/2023 RECORD PLANS LEGEND EASEMENT WATERMAIN SANITARY SEWER EXISTINGPROPOSED STORM SEWER CURB & GUTTER D S S SANITARY SERVICE WATER SERVICE PROPERTY LINE D S S FUTURE PHASE LINE SCALE HORIZONTAL: 1"=50' VERTICAL: 1"=10' THE SUBSURFACE UTILITY INFORMATION SHOWN ON THESE PLANS IS A UTILITY QUALITY LEVEL D. THIS QUALITY LEVEL WAS DETERMINED ACCORDING TO THE GUIDELINES OF ASCE/CI 38-02, TITLED "STANDARD GUIDELINES FOR THE COLLECTION AND DEPICTION OF EXISTING SUBSURFACE UTILITY DATA." THE CONTRACTOR AND/OR SUBCONTRACTORS SHALL DETERMINE THE EXACT LOCATION OF ALL EXISTING UTILITIES BEFORE COMMENCING WORK, BY CONTACTING THE NOTIFICATION CENTER (GOPHER STATE ONE FOR MINNESOTA). THE CONTRACTOR AND/OR SUBCONTRACTOR AGREE TO BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES, WHICH MIGHT BE OCCASIONED BY HIS OR HER FAILURE TO EXACTLY LOCATE AND PRESERVE ANY AND ALL UTILITIES (UNDERGROUND AND OVERHEAD). IF THE CONTRACTOR ENCOUNTERS ANY DRAIN TILE WITHIN THE SITE, HE OR SHE SHALL NOTIFY THE ENGINEER WITH THE LOCATION, SIZE, INVERT AND IF THE TILE LINE IS ACTIVE. NO DRAIN TILE SHALL BE BACKFILLED WITHOUT APPROVAL FROM THE PROJECT ENGINEER. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES WHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THE PLANS. NOTE: CONTRACTOR AND MATERIAL SUPPLIER SHALL DETERMINE THE MINIMUM DIAMETER REQUIRED FOR EACH STORM SEWER STRUCTURE. FES 4001 - FES 4000 FES 3101 - FES 3100 CB 2602 - FES 2600CB 2703 - FES 2700 NOTE: ALL DOWNSTREAM FES STRUCTURES ARE TO INCLUDE A TRASH GUARD NOTE: PIPE LENGTHS INCLUDE FES STORM STRUCTURE TABLE STR. # 2700 2702 2703 4000 4001 3100 3101 TYPE FES CBMH CB FES FES FES FES CASTING R-3067-VB R-3067-V DIA NA 48" 48" NA NA NA NA 2600 2601 2602 2400 2401 2402 FES CBMH CB FES CBMH CBMH NA 48" 24"x36" NA 60" 60" R-3067-V R-3067-V 21" RCP APRON W/ FLEXAMAT R-3067-V R-3067-VB 2403 CB 24"x36"R-3067-VB STR. # 2500 2501 2502 2503 2504 2505 4300 4301 TYPE FES STMH CBMH CBMH CBMH CB FES FES CASTING R-1642 R-3067-V R-3067-V DIA NA 48" 48" 60" 60" 24"x36" NA NA 4100 4101 4102 4200 4201 4202 FES CBMH CB FES STMH FES NA 48" 24"x36" NA 48" NA R-3067-VB R-3067-VB R-1642 R-3067-V R-3067-V 21" RCP APRON W/ FLEXAMAT 18" RCP APRON W/ FLEXAMAT 18" RCP APRON W/ FLEXAMAT 24" RCP APRON W/ FLEXAMAT 24" RCP APRON 24" RCP APRON W/ FLEXAMAT 24" RCP APRON 18" RCP APRON W/ FLEXAMAT 15" RCP APRON 15" RCP APRON 15" RCP APRON W/ FLEXAMAT 15" RCP APRON 2503-A 2503-B CB CBMH 48" 24"x36" R-3067-V R-3067-V 2701 STMH R-164248" SAMBATEK, INC. 12/18/2023 C.W.HOULE, INC. C.W.HOULE, INC. COMPLETED BY: DATE OF COMPLETION: STREET/UTILITY CONTRACTOR: GRADING CONTRACTOR: RECORD PLAN NOTES THESE RECORD PLANS HAVE BEEN PREPARED, IN PART, BASED ON INFORMATION COMPILED AND FURNISHED BY OTHERS. THE ENGINEER HAS NOT VERIFIED THE ACCURACY AND/OR COMPLETENESS OF THE INFORMATION PROVIDED AND SHALL NOT BE RESPONSIBLE FOR ANY ERRORS OR OMISSIONS WHICH HAVE BEEN INCORPORATED INTO THESE RECORD PLANS AS A RESULT.