Loading...
Miske8_8244+0 0 245+00 246+00 247+00 248+00 249+00 250+00 251+00 252+0 0927.70LP0+001+002+003+004+005+006+00935.5933.5931.5929.5927.8928.0928.5934.5932.5930.5928.5927.8928.2926.5 928.7 930.7 932.7 934.7 936.7 938.7 940.7 942.7 927.7 929.7 931.7 933.7 935.7 937.7 939.7 941.7 TWIN LAKES PARKWAY IVANHOESTREETIVANHOESTREET#468 #469 #470 #471 #472#473 #474 #475#476 #477 #489 #490 #491 #492 #493 #494 #495 #275 #260 #261 #262 #263 #264 #265 #266 #267 #273 #274 #263A 927.43 HP DEVELOPMENT#488#487#486 INFILTRATION BASIN 9 BTM:922 (20,800 SF) OUT: 924.0 HWL: 925.4 EOF: 928.5 OUTBOT HWL CB 2403 CBMH 2402 CBMH 2401 FES 2400 CB 2505 CBMH 2504 CBMH 2503 CBMH 2502 STMH 2501 FES 2500 2503-A 2503-B ADJUST EXISTING STORM MANHOLES AS NECESSARY. OUTLOT C 5 6 7 8 9 10 11 4 5 6 7 8 9 10 11 12 13 14 1 2 3 4 5 6OUTLOT G BLOCK 2 BLOCK 3 BLOCK 4 880 890 900 910 920 930 940 950 880 890 900 910 920 930 940 950 8" SAN XING IE=906.3 8" WM XINGCB 2403 (24"X36")RE=927.20BLD=3.5'IE=923.70 E31 LF - 18" RCP @ 0.35%CBMH 2402 (60")RE=927.20BLD=3.6'IE=923.59 WIE=923.59 S11 LF - 21" RCP @ 0.40%CBMH 2401 (60")W/ SAFL BAFFLERE=927.20BLD=7.2'IE=920.05 (3.5' SUMP)IE=923.55 NIE=923.55 E155 LF - 21" RCP @ 0.55% FES 2400FLEXAMAT OR APPROVED EQUALIE=922.7 W (21" )PROPOSED GRADE927.083.0924.04927.123.5923.66923.66927.146.6923.76923.76920.59922.8233 10 149 1.00 1.15 0.63 890 900 910 920 930 940 950 960 890 900 910 920 930 940 950 960 8" WM XING 8" SAN XING IE=914.9 PROPOSED GRADE INSULATE W/ 3" MIN. FOAMBOARD CB 2505 (24"X36")RE=941.50BLD=3.5'IE=938.00 SE33 LF - 15" RCP @ 0.50%CBMH 2504 (60")RE=941.70BLD=3.9'IE=937.84 NWIE=937.84 W247 LF - 18" RCP @ 2.10%CBMH 2503 (60")RE=936.83BLD=8.6'IE=932.65 EIE=928.54 WIE=928.54 N31 LF - 18" RCP @ 1.75%CBMH 2502 (48")W/ SAFL BAFFLERE=936.83BLD=12.3'IE=924.49 (3.5' SUMP)IE=927.99 SIE=927.99 N137 LF - 18" RCP @ 3.65%STMH 2501 (48")RE=927.30BLD=4.3'IE=923.00 SIE=923.00 NE30 LF - 21" RCP @ 1.00% FES 2500FLEXAMAT OR APPROVED EQUALIE=922.7 SW (21" )927.444.2923.24923.24922.88936.5412.0927.92927.92924.51936.527.7932.59928.86928.86941.373.7937.71937.71941.203.4937.8223 1.57 3.39 138 33 2.85 2.07 0.32247 34 910 920 930 940 950 910 920 930 940 950 CBMH 2503 (60")RE=936.83BLD=8.6'IE=932.65 EIE=928.54 WIE=928.54 N193 LF - 18" RCP @ 0.30%2503-A (48")RE=932.8BLD=3.78'IE=929.12 SWIE=929.12 E32 LF - 15" RCP @ 0.30%2503-B (24"X36")RE=932.75BLD=3.53'IE=929.22 NEPROPOSED GRADE932.793.2929.56932.853.5929.34929.34936.527.7932.59928.86928.8632 192 0.25 0.69 Dec 18, 2023 - 9:41am - User:tkeeley L:\PROJECTS\20460.06\CAD\Record Plan\Miske Meadows 8th Addition Record Plans\20460.80 - C7-RP-STORM.dwg C7.02 STORM SEWER Project Location Date Submittal / RevisionNo. Certification Sheet Title Summary Revision History Sheet No.Revision Project No. By Designed:Drawn: Approved:Initial Issue: Phase: Client LGI HOMES- Minnesota, LLC 2850 CUTTERS GROVE AVENUE SUITE 207 ANOKA, MN 55303 MISKE MEADOWS EIGHTH ADDITION ELK RIVER, MN JEB TPK/CE/JLB ETL CONSTRUCTION 06/30/2022 20460.80 I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly licensed professional ENGINEER under the laws of the state of Minnesota. If applicable, contact us for a wet signed copy of this plan which is available upon request at Sambatek's, Minnetonka, MN office. Registration No.Date:06/30/202250475 Eric T. Luth 06/30/2022 CONSTRUCTION DOCUMENTS 6/08/2023 RECORD PLANS LEGEND EASEMENT WATERMAIN SANITARY SEWER EXISTINGPROPOSED STORM SEWER CURB & GUTTER D S S SANITARY SERVICE WATER SERVICE PROPERTY LINE D S S FUTURE PHASE LINE THE SUBSURFACE UTILITY INFORMATION SHOWN ON THESE PLANS IS A UTILITY QUALITY LEVEL D. THIS QUALITY LEVEL WAS DETERMINED ACCORDING TO THE GUIDELINES OF ASCE/CI 38-02, TITLED "STANDARD GUIDELINES FOR THE COLLECTION AND DEPICTION OF EXISTING SUBSURFACE UTILITY DATA." THE CONTRACTOR AND/OR SUBCONTRACTORS SHALL DETERMINE THE EXACT LOCATION OF ALL EXISTING UTILITIES BEFORE COMMENCING WORK, BY CONTACTING THE NOTIFICATION CENTER (GOPHER STATE ONE FOR MINNESOTA). THE CONTRACTOR AND/OR SUBCONTRACTOR AGREE TO BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES, WHICH MIGHT BE OCCASIONED BY HIS OR HER FAILURE TO EXACTLY LOCATE AND PRESERVE ANY AND ALL UTILITIES (UNDERGROUND AND OVERHEAD). IF THE CONTRACTOR ENCOUNTERS ANY DRAIN TILE WITHIN THE SITE, HE OR SHE SHALL NOTIFY THE ENGINEER WITH THE LOCATION, SIZE, INVERT AND IF THE TILE LINE IS ACTIVE. NO DRAIN TILE SHALL BE BACKFILLED WITHOUT APPROVAL FROM THE PROJECT ENGINEER. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES WHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THE PLANS. CB 2403 - FES 2400 FES 2500 - CB 2505 SCALE IN FEET 0 10050 NORTH SCALE HORIZONTAL: 1"=50' VERTICAL: 1"=10' NOTE: CONTRACTOR AND MATERIAL SUPPLIER SHALL DETERMINE THE MINIMUM DIAMETER REQUIRED FOR EACH STORM SEWER STRUCTURE. NOTE: ALL DOWNSTREAM FES STRUCTURES ARE TO INCLUDE A TRASH GUARD CB 2503B - CBMH 2503 NOTE: PIPE LENGTHS INCLUDE FES STORM STRUCTURE TABLE STR. # 2700 2702 2703 4000 4001 3100 3101 TYPE FES CBMH CB FES FES FES FES CASTING R-3067-VB R-3067-V DIA NA 48" 48" NA NA NA NA 2600 2601 2602 2400 2401 2402 FES CBMH CB FES CBMH CBMH NA 48" 24"x36" NA 60" 60" R-3067-V R-3067-V 21" RCP APRON W/ FLEXAMAT R-3067-V R-3067-VB 2403 CB 24"x36"R-3067-VB STR. # 2500 2501 2502 2503 2504 2505 4300 4301 TYPE FES STMH CBMH CBMH CBMH CB FES FES CASTING R-1642 R-3067-V R-3067-V DIA NA 48" 48" 60" 60" 24"x36" NA NA 4100 4101 4102 4200 4201 4202 FES CBMH CB FES STMH FES NA 48" 24"x36" NA 48" NA R-3067-VB R-3067-VB R-1642 R-3067-V R-3067-V 21" RCP APRON W/ FLEXAMAT 18" RCP APRON W/ FLEXAMAT 18" RCP APRON W/ FLEXAMAT 24" RCP APRON W/ FLEXAMAT 24" RCP APRON 24" RCP APRON W/ FLEXAMAT 24" RCP APRON 18" RCP APRON W/ FLEXAMAT 15" RCP APRON 15" RCP APRON 15" RCP APRON W/ FLEXAMAT 15" RCP APRON 2503-A 2503-B CB CBMH 48" 24"x36" R-3067-V R-3067-V 2701 STMH R-164248" SAMBATEK, INC. 12/18/2023 C.W.HOULE, INC. C.W.HOULE, INC. COMPLETED BY: DATE OF COMPLETION: STREET/UTILITY CONTRACTOR: GRADING CONTRACTOR: RECORD PLAN NOTES THESE RECORD PLANS HAVE BEEN PREPARED, IN PART, BASED ON INFORMATION COMPILED AND FURNISHED BY OTHERS. THE ENGINEER HAS NOT VERIFIED THE ACCURACY AND/OR COMPLETENESS OF THE INFORMATION PROVIDED AND SHALL NOT BE RESPONSIBLE FOR ANY ERRORS OR OMISSIONS WHICH HAVE BEEN INCORPORATED INTO THESE RECORD PLANS AS A RESULT.