Loading...
Miske8_9253+ 0 0 254+00255+00930 . 1 3 LP 1 3 + 9 6 . 0 6 7 + 0 0 8+ 0 0 9 + 0 0 10+0011+ 0 0 12 + 0 0 13+0 0 931.0 9 4 9 . 8 94 7 . 9 9 4 5 . 7 941.093 6 . 1 93 1 . 8 930. 1 94 8 . 7 94 7 . 2 94 3 .5938.6 9 3 3 . 7 930 . 6 93 0 . 3 948.09 HP 944.7 946.7948.1946.5945.7 947.7947.6NW LAKES PARKWAY #497 #498 #499 #500 #466 #501 #502 #503 #505 #506 #507 #508 #509 #510 #511 #512188THAVENW INFILTRATION BASIN 11 BTM:925.0 (8,500 SF) OUT:926.0 HWL:927.9 EOF:928.4 INFILTRATION BASIN 15 BTM: 925.0 (16,000 SF) HWL: 928.3 EOF:930.5 INFILTRATION BASIN 16 BTM: 925 (1,000 SF) OUT:927.0 HWL:928.6 EOF:930.5 BOT HWL OUTBOT HWL FES 4301 FES 4300 FES 4202 STMH 4201 FES 4200 FES 4100 CBMH 4101 CB 4102 OUTLOT D OUTLOT E15 16 9 10 11 12 13 14 1 2 3 4 5 6 7 8 BLOCK 5 900 910 920 930 940 950 960 900 910 920 930 940 950 960 PROPOSED GRADE 75 LF - 15" RCP @ 0.00% FES 4202IE=925.0 E (15" )60 LF - 15" RCP @ 0.00%STMH 4201 (48")RE=930.66BLD=5.7'IE=925.00 WIE=925.00 E FES 4200IE=925.0 W (15" )931.075.6925.45925.45925.60925.4171 0.21 53 0.08 890 900 910 920 930 940 950 960 890 900 910 920 930 940 950 960 8" WM XING 8" SAN XING IE=919.3 PROPOSED GRADE INSULATE W/ 3" MIN. FOAMBOARD FES 4100FLEXAMAT OR APPROVED EQUALIE=925.0 E (18" )56 LF - 18" RCP @ 1.00%CBMH 4101 (48")W/ SAFL BAFFLERE=929.88BLD=7.8'IE=922.08 (3.5' SUMP)IE=925.58 NEIE=925.58 W32 LF - 15" RCP @ 1.00%CB 4102 (24"X36")RE=929.90BLD=4.0'IE=925.90 SW924.96929.557.8925.40925.40921.80929.503.7925.820.86 51 1.27 33 900 910 920 930 940 950 960 900 910 920 930 940 950 960 8" WM XING 8" SAN XING IE=919.0 PROPOSED GRADE INSULATE W/ 3" MIN. FOAMBOARD 211 LF - 15" RCP @ 2.84% FES 4301IE=927.0 NE (15" ) FES 4300FLEXAMAT OR APPROVED EQUALIE=921.0 SW (15" )926.85921.172.80 203 Dec 18, 2023 - 9:42am - User:tkeeley L:\PROJECTS\20460.06\CAD\Record Plan\Miske Meadows 8th Addition Record Plans\20460.80 - C7-RP-STORM.dwg C7.03 STORM SEWER Project Location Date Submittal / RevisionNo. Certification Sheet Title Summary Revision History Sheet No.Revision Project No. By Designed:Drawn: Approved:Initial Issue: Phase: Client LGI HOMES- Minnesota, LLC 2850 CUTTERS GROVE AVENUE SUITE 207 ANOKA, MN 55303 MISKE MEADOWS EIGHTH ADDITION ELK RIVER, MN JEB TPK/CE/JLB ETL CONSTRUCTION 06/30/2022 20460.80 I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly licensed professional ENGINEER under the laws of the state of Minnesota. If applicable, contact us for a wet signed copy of this plan which is available upon request at Sambatek's, Minnetonka, MN office. Registration No.Date:06/30/202250475 Eric T. Luth 06/30/2022 CONSTRUCTION DOCUMENTS 6/08/2023 RECORD PLANS LEGEND EASEMENT WATERMAIN SANITARY SEWER EXISTINGPROPOSED STORM SEWER CURB & GUTTER D S S SANITARY SERVICE WATER SERVICE PROPERTY LINE D S S FUTURE PHASE LINE THE SUBSURFACE UTILITY INFORMATION SHOWN ON THESE PLANS IS A UTILITY QUALITY LEVEL D. THIS QUALITY LEVEL WAS DETERMINED ACCORDING TO THE GUIDELINES OF ASCE/CI 38-02, TITLED "STANDARD GUIDELINES FOR THE COLLECTION AND DEPICTION OF EXISTING SUBSURFACE UTILITY DATA." THE CONTRACTOR AND/OR SUBCONTRACTORS SHALL DETERMINE THE EXACT LOCATION OF ALL EXISTING UTILITIES BEFORE COMMENCING WORK, BY CONTACTING THE NOTIFICATION CENTER (GOPHER STATE ONE FOR MINNESOTA). THE CONTRACTOR AND/OR SUBCONTRACTOR AGREE TO BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES, WHICH MIGHT BE OCCASIONED BY HIS OR HER FAILURE TO EXACTLY LOCATE AND PRESERVE ANY AND ALL UTILITIES (UNDERGROUND AND OVERHEAD). IF THE CONTRACTOR ENCOUNTERS ANY DRAIN TILE WITHIN THE SITE, HE OR SHE SHALL NOTIFY THE ENGINEER WITH THE LOCATION, SIZE, INVERT AND IF THE TILE LINE IS ACTIVE. NO DRAIN TILE SHALL BE BACKFILLED WITHOUT APPROVAL FROM THE PROJECT ENGINEER. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES WHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THE PLANS. FES 4301 - FES 4300 FES 4100 - CB 4102 FES 4202 - FES 4200 SCALE IN FEET 0 10050 NORTH SCALE HORIZONTAL: 1"=50' VERTICAL: 1"=10' NOTE: CONTRACTOR AND MATERIAL SUPPLIER SHALL DETERMINE THE MINIMUM DIAMETER REQUIRED FOR EACH STORM SEWER STRUCTURE. NOTE: ALL DOWNSTREAM FES STRUCTURES ARE TO INCLUDE A TRASH GUARD NOTE: PIPE LENGTHS INCLUDE FES STORM STRUCTURE TABLE STR. # 2700 2702 2703 4000 4001 3100 3101 TYPE FES CBMH CB FES FES FES FES CASTING R-3067-VB R-3067-V DIA NA 48" 48" NA NA NA NA 2600 2601 2602 2400 2401 2402 FES CBMH CB FES CBMH CBMH NA 48" 24"x36" NA 60" 60" R-3067-V R-3067-V 21" RCP APRON W/ FLEXAMAT R-3067-V R-3067-VB 2403 CB 24"x36"R-3067-VB STR. # 2500 2501 2502 2503 2504 2505 4300 4301 TYPE FES STMH CBMH CBMH CBMH CB FES FES CASTING R-1642 R-3067-V R-3067-V DIA NA 48" 48" 60" 60" 24"x36" NA NA 4100 4101 4102 4200 4201 4202 FES CBMH CB FES STMH FES NA 48" 24"x36" NA 48" NA R-3067-VB R-3067-VB R-1642 R-3067-V R-3067-V 21" RCP APRON W/ FLEXAMAT 18" RCP APRON W/ FLEXAMAT 18" RCP APRON W/ FLEXAMAT 24" RCP APRON W/ FLEXAMAT 24" RCP APRON 24" RCP APRON W/ FLEXAMAT 24" RCP APRON 18" RCP APRON W/ FLEXAMAT 15" RCP APRON 15" RCP APRON 15" RCP APRON W/ FLEXAMAT 15" RCP APRON 2503-A 2503-B CB CBMH 48" 24"x36" R-3067-V R-3067-V 2701 STMH R-164248" SAMBATEK, INC. 12/18/2023 C.W.HOULE, INC. C.W.HOULE, INC. COMPLETED BY: DATE OF COMPLETION: STREET/UTILITY CONTRACTOR: GRADING CONTRACTOR: RECORD PLAN NOTES THESE RECORD PLANS HAVE BEEN PREPARED, IN PART, BASED ON INFORMATION COMPILED AND FURNISHED BY OTHERS. THE ENGINEER HAS NOT VERIFIED THE ACCURACY AND/OR COMPLETENESS OF THE INFORMATION PROVIDED AND SHALL NOT BE RESPONSIBLE FOR ANY ERRORS OR OMISSIONS WHICH HAVE BEEN INCORPORATED INTO THESE RECORD PLANS AS A RESULT.