Loading...
5.4. SR 09-20-1993 rll ---\) ( )j rl~ ITEM 5.4. TO: FROM: MAYOR AND CITY COUNCIL GARY SCHMITZ, ZONING ASSISTANT ~~~ DATE: SEPTEMBER 20, 1993 SUBJECT: ABOVE GROUND STORAGE TANK REQUESTED ACTION Bill Dickenson, who owns the bus terminal located at 19101 Jackson Road, is requesting to add a 10,000 gallon, insulated, double-wall above ground storage tank to his bus terminal. The tank will be used to replace two underground storage tanks, which are approximately 30,000 gallons in combined size. The reason that this item is being presented to the City Council is that the State Fire Marshalls Office requires a State variance for any above ground storage tank larger than 6,000 gallons. Part of the State variance procedure is to show through certified minutes that this item has been reviewed and approved by the City Council. e The City Council has the right to either deny the request, approve the request with more stringent requirements, or to approve the request and use the State standards for the placement of the above ground storage tanks. The State standards for above ground storage tanks are as follows: 1. The tank must be located 50 feet from any buildings. 2. The tank must be located 50 feet from any type of dispenser (gas pump). 3. The tank must be located 50 feet from any public right-of-way. 4. The tank must be located 100 feet from any property line. Mr. Dickenson wants an above ground tank because leaks and other problems will be easier to detect and fix, versus the underground tanks he currently has. This particular 10,000 gallon storage tank is also portable, which will allow Mr. Dickenson to move (if, and when his bus terminal is moved for the placement of another commercial use). e Lastly, new laws require that existing storage tanks meet new State standards. It is Mr. Dickenson's opinion that to update his underground storage tanks to meet new State requirements would cost several thousand dollars. These tanks would also not be easily moved. P.O. Box 490 · 13065 Orono Parkway · Elk River, MN 55330 · (612) 441-7420 · Fax: (612) 441-7425 e e e Storage Tanks, Dickenson September 20, 1993 Page 2 ------------------------ RECOMMENDATION Staff recommends the City Council recommend approval to allow a 10,000 gallon above ground storage tank on this site to replace the existing underground tanks. Staff would also recommend using the State requirements for the placement of this tank. Mr. Dickenson will be at Monday night's meeting to answer any questions you may have regarding this request. ..