Loading...
8.1. SR 11-13-2006 City of Elk River REQUEST FOR COUNCIL ACTION Agenda Section Meeting Date StaffU dates November 13, 2006 Item Description ECONAR Donation U date Item Number 8.l. Prepared by Bill Maertz, Parks and Recreation Director Reviewed by Introduction ECONAR donation update Discussion At the November 3, 2006 City Council meeting the Council voted to accept the donation of heat pumps from ECONAR for the library project At that time staff did not have information regarding the value of the credit the city would receive from the contractor. Attached please find the change order to the library contract. The credited amount is $40,000. KKE architects have reviewed the change order and believe that it is fair and equitable. Financial Impact Attachments · Change order Action Requested None Council Action Motion by _ Second by _ Vote Follow Up C: \Documents and Settings \ tallard\Local Settings \ Temporary Internet Files \ OLKF\Staff Update. doc ...u-AIX Document G701'" - 2001 Change Order PROJECT (Name and address): Elk River Library Orono Parkway Elk River, MN 55330 TO CONTRACTOR (Name and address): MerrimacConstluction Company, Inc. 15651 Buchanan Street NE EastBethel, MN 55011 CHANGE ORDER NUMBER: 001 DATE: November 08, 2006 OWNER: IZI ARCHITECT: IZI CONTRACTOR: IZI FIELD: 0 OTHER: 0 ARCHITECT'S PROJECT NUMBER: KKE 0606.1159.21 CONTRACT DATE: October 03,2006 CONTRACT FOR: General Construction rME CONTRACT IS CHANGED AS FOLLOWS: (Include, wh.ere applicable, any undisputed amount attributable to previously executed Construction Change Directives) Creditforhearpump to be provided by Owner, warranty by Supplier as per specifications. Refer to Proposal Request No.1. $ $ $ $ $ 3,937,155.00 0.00 3,937,155.00 40,000 3,897,155.00 The original Contract Sum was The net changeby:previously authorized Change Orders The Contract Sum prior. to this Change Order was The Contract S umwiIl be decreased by this Change Order in the amount of The new ContractSulTl includhlg this Change Order will be The Contract Time will be increased by Zero ( 0 ) days. The date of Substantial Completion as of the date of this Change Order therefore is NOTE: This Change Order does not include changes in the Contract Sum, Contract Time or Guaranteed Maximum Price which have been authorized by Construction Change Directive until the cost and time have been agreed upon by both the Owner and Contractor, in which case a Change Order is executed to supersede the Construction Change Directive. NorVALlDUNTILSIGNED BY THE ARCHITECT, CONTRACTOR AND OWNER. KKEArchitects; Inc. ARCHITeCT (Film name) Merrimac Construction Company, Inc. CONTRACTOR (Film name) 15651 Buchanan Street NE, East Bethel, MN 55011 ADDRESS City of Elk River OWNER (Firm name) 13065 Orono Parkway, Elk River, MN 55330 ADDRESS BY (Signature) Richard Szurek (Typed name) BY (Signature) Bill Maertz (Typed name) DATE DATE AlA Document G70FM - 2001. Copyright @ 1979, 1987, 2000 and 2001 by The American Inslltute of Architects. All rights reserved. WARNING: This AlA'" Document Is protected by U.S. Copyright Law and Internallonal Trealles. Unauthorized reproducllon or dlstribullon of this AlA" Document, or any 1 porllon of II, may result In seVere civil and criminal penalties, and will be prosecuted to the maximum extent possible under the law. This document was produced by AlA software at 12:02:12 on 11/08/2006 under Order No.1000255740_ 4 which expires on 8/24/2007, and Is not for resale. User Notes: (3633753831) .....11/07/2006 16:35 ::::: ::-:-Request for Change Order Proposal Merrimae Construction Co.. Inc. 18651 Buchanan Street NE East Bethel, MN 55011 Phone: (763) -434-6857 Fa~: (763) -434-6568 7534345558 MERRIIv1AC PAGE 01 MERR # 1 Fax#: KKE Architects Jennifer Anderson-Tuttle 612-342-9267 Dick S"Rlk ~~_..., /,-~":' '" .:' .. n n-- /h...., (. .... /1.. 11'" I ' I..:::J ff' c, \\ ,.1/ ,'. \ V / I ~::') 1"'\ \ 4 .-~O~ -;1~~6 -~;J>> To: Attn.: From: Project: Elk River P~_~Ii?_~~bral)' Pages: Project #: 060196 Owner: . ~,!!Y.. of EII( River Date: 11/07/2006 ~(I<~S /.\F1CH. COMM. NO ................~-'""'......-<>--~ Description of Change: Credit For Heal pumps Par PR # 1 I Amount: ( $40,000.00) If you have any questions concerning thl9 Issue. ple~se call as 900n 8S possible. so any discrepancies can be addressed. This price is void withIn 30 days if not accepted. If this change is a~pted by the owner. this will entitle Marrlmac Construction to additional lime to be detarmioQd at a later data. Please note. all changes will effect the completion date for this project. Please advise If Marrlmae Construction is to proceed with this change. With this fax you will find a copy of our supplemental Proposals and breakdown. 11/07/2005 15:35 7534345558 IvlERRn1AC PAGE 02 1 SUPPLEMENTAL PROPOSAL MGrrimac Construction Co., Inc. DESCRIPTION OF CHANGE: Credit For Heet Pumps Per PR # 1 [.. ". .., , ". ". """". ..'." ...... . .... PRlMI"OONTRl!;cTO.RS'WQRK" , ." "'" " "'..' .."...... .",. " "" "'~. ".' .... "". "C<)MME . . "i. '1 ";.;.~;~;,_:":"':..:' '61~~;;"M;l~ri~i~~:': :,,' ...--..-'. ............. ......... .1.i.......... .,.. ..........:.:..::: ::::;:"::o~'oo~;:~~;.;...,.... .,,".. ,,": .,:::. ":<.. '-~~...' ..... .:.. ;:c..:,' 2 Sales Tax on MaterIals @ 7.00% 0.00" 3 Direct Labor ", 0.00 4 lIability & Workers Compo Insurance 0.00 5 Rental EquIpment 0.00 6 Sales Tax on Rental Equipment 0.00 7 EquipmBnt Ownership and Operating Exp. 0.00 B FICAlFUTNSUTA 0.00 9 Field Related ActivIties 0.00 9.5 Labor Associated with Change 0.00 10 TOTAL CONTRACTORS WORK (add lines 1-9) i. 11!M," ~ l, 'it . 110: " Direct Materials Sales Tax on Matl;lrials @ Direct Lebor LIability & Workers Compo Insurance Rental Equipment Sales Tax on Rental Equipment Equipment Ownership and Operating Expense FICNFUTAJSUTA Subcontractors Field OH&P Major 6ubcontracto1'9 home office overhead Major subcontractor profit Major Subcontraoto1'9 Cost ('add lines 11-21) Minor Subcontractor's cost includIng OH&P (sum) SUBCONTRACTORS TOTAL (add lines 22-23) . ': '1 ~ T:d:>Y.l~!I:!';1 I 11 12 13 14 15 16 17 18 19 2.0 21 22 23 24 '~;i~I:S~:1::;~1:1i~r.~~!;:;!:.:~~.;!\~.it.I~~!I;:j!jl~t~:1:;lii!:{!f~i'~I'.!.!;\: '. , ,I ~~:::;~i~~~fic~~!;?~;.:~;IU~ i(1,~tlii):1j'I::\:' "~'H ,11..l.II"'ll1li.:-'I:' '.:!J;:~,t.!lr~Q:~il":"-n':I.T'~J:" \"1".:\1 !'T" ...:...:.....:..~:.::.,3l.;.,.~lo.;!.ut,.....".,.; ",~'r.,l-'!~~'.!.l.t~I~31~11,~l~ 25 Prime Contractor's Work (from line 1 0) 26 Subcontractor's Work (from line 24) 27 SUBTOTAl. (add lines 26-27) 28 Prime Allowance on Subcontractor 29 Permits 30 Prime Contractors Markup 31 CONTRACTORS SUBTOTAL (add lines 2.3-24) 32 Prime Contractor's Bond Premium 33 TOTAl. COST (Add Lines 30-31) E9t1mated time extension and justi lcation: Prim'a "Contractor name:-.... Marrimae Construction Co., Ino: TiUe of repared: DICK SZUR~K V. PRESIDENT 11/07/2005 15:35 7534346568 BREAKDOWN OF DIRECT COSTS Marrimae Construction Co., Inc. Credit For Heet Pumps Par PR # 1 :b~m:a~(:g~~r~:r~~J1j\:!j:+(:(:W.:ji;:;'r:: ;yL....~1Y. UNIT .:: Ptlnla!oar'1t~cto' $.', .,..... .: ~ . . QTY. UNIT 'C1'H5RSUSCONTRAOrOR'CQS~.. '. "\ Q1Y. UNIT ( Suppo~iiig ~afi9tiifcMdr . ",::::::, ~;:: :.:, ....... .._._._ .. ..w."." . .... 1. Ehlay Plumbing 1.00 LS. :,.;.,::. ':":::'''.:''. {tier 9ubCcntractd.,~: " 1.8 '. : " ".. tvlERRItvlAC PAGE 03 MERR # 1 MATER1AC uriifCost LABOR EQUIPMENT Unit Cos Total Cost Unit Cos Totsl Cost Totel Cosf 0.00- 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 MATERIAL -tABOR EQUIPMENT' Unit Cost '"Total Cost Unit C09 Total Cost Unit Cost Total Cost 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0,00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 ~OO ~OO QOO ,1ft! 11 ' , COST Unit Cost ....Total Cost " 0.00 (40.000.00) ( 40,000.00) 0.00 0.00 0,00 0.00 0.00 ..: ,.,: .: ".' 40,000.00) 11/07/2005 15:35 11/07/2006 16:11 PAGE 04 PAGE Ell .. ~ 7534345558 MERRIMAC EL JAY 32El2514133 EL~.JAV'= . " Plumbing & fieating, Inc 1 T Mechanical .contractors , ., November 7th,.2006 Merrimac Construction . . 18651 Buchanan Street N.H. East Bethel, MN 55011 Attn: Josh Dixon Re: Elk River Library Josh, The ~edu.ct price for the Elk River Library heat pumps, to now be furnished by th~ owner is $40,000.00, . .owner will supply own heat pumps. Warranty .by new sl;1p.plier. . Thank You Bruce Eckrnan Proj ect Ivlanager 520 Apollo Ave. Nc '" St,. Cloud. MN 5E9304 011 Telephone: (320) 251-8330 · Fax: ,(320) 251"41.33 r . . PROPOSAL REQUEST Karges-Faulconbridge, Inc. Engineers 670 West County Road B St. Paul, MN 55113-4527 Phone: 651-771-0880 Fax: 651-771-0878 E-Mail kfi@kfi-eng.com Date: Project: KFI Project Number: 10-20-06 Elk River Library 06-089.00 Proposal Req. Number: KFI Prop. Req. Number: PR-1 PR-KFI-1 Requested By: Christopher D. Nelson THIS PROPOSAL REQUEST IS A CONTRACT DOCUMENT AND MAY APPLY TO ANY OR ALL CONTRACTS AND SUBCONTRACTS UNLESS OTHERWISE SPECIFIED HEREIN OR SHOWN ON THE ATTACHED DRAWINGS (IF ANY). ALL WORK REQUIRED BY THIS PROPOSAL REQUEST SHALL BE IN COMPLETE ACCORD WITH THE CONTRACT DOCUMENTS AND SUBSEQUENT PROPOSAL REQUESTS THERETO. THE ITEMS LISTED IN THIS PROPOSAL REQUEST ARE NOT IN ANY ORDER IN REGARD TO THE DRAWINGS OR THE SPECIFICATIONS. ALL CONTRACTORS ARE CAUTIONED TO EXAMINE EACH AND EVERY ITEM OF THIS PROPOSAL REQUEST. PLEASE SUBMIT A PROPOSAL TO MAKE THE FOLLOWING CHANGES TO THE CONTRACT DOCUMENTS. SEPARATE ANY COST ADDITIONS OR CREDITS BY ITEM NUMBER. NOTE: FSK NUMBERS ARE ARBITRARY UNIQUE TAGS AND MAY NOT BE ALL USED OR IN ORDER. SPECIFICATION CHANGES: 1. NONE 2. PLAN SHEET CHANGES: 1. NONE 2. EXPLANATION OF REQUEST: 1. Provide individual material credits for heat pumps: HP-1, HP-2, and HP-3 as specified in the construction documents. Owner to furnish three 20 ton Econar heat pumps as a substitute for the specified heat pumps. Contractor shall coordinate the delivery/storage and provide the installation of the Econar heat pumps per the contract documents for a fully functional system. 2. Provide a detailed material credit list for each heat pump and any additional costs associated with this material change for a total credit. This information is to be delivered to the Engineer and Architect by November 1,2006 (12 noon). ATTACHMENTS: 1. Econar product data sheets. 2. END OF PROPOSAL REQUEST QMF 03-013 Issue 2 Elk River Library ECONAR GW 2400 Performance Data Project Design Conditions October 6,2006 Heatina Heatina Coolina Source E\NT 45 75 75 L\NT 35 65 90 GPM 41 41 41 PO (psi) 2.5 2.5 2.5 Load E\NT 100 100 55 LWT 120 120 45 GPM 28.8 38 41.5 PO (psi) 1.6 2.1 2.6 COP & EER 3.2 4.6 15.3 Capacity Mbtuh 235 330 228 30% Glvcol Mbtuh 228 319 221 Electrical 208/230 3 phase 60Hz RLA 33.3 x 2 LRA 239 x 2 MCA 74.9 GeoSource Heat Pumps . R-410A Refrigerant GeoSource Ultra G\V Hydronic Models Engineering Guide Specifications General: The GeoSource heat pump system and the ground loop field shall be one system and include all interconnecting piping and controls to provide an efficient, harmoniously-balanced package. Ground Loop: The ground loop field shall be constructed of high-density polyethylene or poly- butylene piping. Its layout shall be of parallel circuits terminated at a reducing header of reverse-return design. All underground joints shall be fusion-welded. The ground loop field shall be designed to provide a 250F water/antifreeze mixture to the heat pumps during the month of January. The antifreeze shall be GTF heat transfer fluid mixed 50% by volume with water of 100-PPM grain hardness or less. The heat pumps shall work over extended-range ground-loop temperature variations (150F to 11 OOF). The piping shall consist of sufficient pump capacity with suction and discharge pressure ports. Valves shall be incorporated for purging all debris and air from the total system. All backfilling and grouting shall be done in accordance with IGSHP A guidelines. All heat pumps shall be installed with PIT ports for pressure and temperature measurement. Cabinet: The heat pump cabinet shall be constructed of heavy-gauge Galvaneal corrosion- resistant steel coated with a baked-on powder epoxy finish and shall be insulated with 1/2" high-density fiberglass insulation. It shall be oriented to allow complete component service access from the front. Legend for Tables BTU/hr CAP COP CFM DB DHW dP EER EWT FLA Heating or cooling capacity Capacity Coefficient of performance (BTU/hr out + BTU/hr in) Cubic feet per minute Dry-bulb entering air temperature Domestic hot water Pressure drop across heat pump (in feet of water and psi) Energy efficiency ratio (BTU/hr out + watts in) Entering water temperature (in degrees Fahrenheit) Full-load amperage Refrigerant Circuit: Compressors shall be hermetically-sealed high-efficiency compliant scroll mounted on vibration isolators. The water heat exchanger shall be either non-coaxial open- center canister-type with enhanced heat exchanger surface, or stainless steel brazed plate. An optional domestic water desuperheater coil of vented double copper construction for potable water shall have an over-temperature control. The expansion device shall be a bi-flow thermostatic metering valve. The reversing valve shall be of copper construction with 24VAC control with fail-to-heating positioning. All heat pumps shall have a factory-installed filter/drier. Controls: All units shall incorporate both low- and high-pressure switches and freeze protection with total refrigerant lockout and manual reset upon application. All units shall have random start and be anti-short cycle protected. Testing and Warranty: All heat pumps shall be factory run-tested with ASHRAE test lab standards at simulated design conditions for a minimum of two hours to assure component and system integrity. All units shall be tested by and rated in accordance with IS0-13256 and CSA C22.2 test laboratory safety and performance standards. All heat pumps shall carry a 2/5 residential or a 1/5 commercial warranty. GPM Gallons per minute of water flow HE Heat extracted HR Heat rejected KW Kilowatt input LRA Locked-rotor amperage MBTU/hr Btulhr X 1000 RLA Rated-load amperage VA Volt-amperes WB Wet. bulb entering air temperature All Pressure Drop Ratings are for Pure Water Performance values are +/- 10%, and are subject to change without notice. Key to Model Numbers G W ~.1 Q - ! - J1.Q Q 0 GeoSource STYLE T L WATER COIL V = Vertical (Forced Air) 0= Standard H = Horizontal (Forced Air) N = Cupro Nickel Well Water Coil C = Console (Forced Air) P = Cupro Nickel Hydronic Coil W = Water (Hydronic) V = Cupro Nickel Well Water and D = Domestic (Hot Water) Hydronic Coil NO~llNALCOOLrnGCAPACITY X 1,000 BTU/hr UNIT TYPE o = Standard D = Demonstrator DESUPERHEATER OPTION H = Heat only (Hydronic) 0= None S = Special 1 = Part Time, 65% DHW T = Staged Tandems U = Staged Tandems Heat Only ELECTRICALSUPPL Y OPTION 2 = Two-Step Compressor (Yara 2 Plus) I =208/230V-l,60Hz 2 =2081230V-3, 60Hz 3 = 460V-3, 60Hz 4 = 2201240V -150Hz 5 = 277V-l, 60Hz AIR OPTION 9 = 380V-3, 50Hz 0= Standard A = 200/220V-3, 50Hz R = Right Return Vertical B = Bottom Discharge Right Return Vertical C = Front Right Discharge Horizontal DESIGN D = GeoSource DualTEK t V = GeoSource Vara, Vara 2 Plus U = GeoSource Ultra , 1 Performance Ratings GjOsource Ultra H dronic Models: Ground Loop . .. , ~[ " . ..' .-- . r,. ,,4,~EK"d))i:W~ ~$Si 'WL '" , , ".'. ~\'il~'.(';Tjmr~~,~qQ:eJ1(~~~;J,lW1h, ,QP1i~if,p,m ,. GW370/~n>,<" 5 8 29,800 3.4 31,900 5.1 33,300 16.4 GW4701471"/":'"'' 7 11 40,700 3.5 43,900 5.4 46,200 16.3 GW5701571 . ....' 9 13 49,700 3.3 54,900 5.0 53,900 16.3 GW770/77L,)' 12 15 65,800 3.2 69,700 5.2 62,100 14.7 GW870/871i,j;X 14 21 75,600 3.3 80,100 5.2 71,400 15.6 GWt'lOO/l101,;:;; 18 26 100,500 3.0 101,900 4.4 102,200 14.0 GW2400/2401,,"': 48 60 221,800 3.3 244,500 5.0 242,700 15.5 Rated outside the scope of the ISO 13256-2 Groundsource Closed-Loop Heat Pump Certification Program Configuration Options GeoSource Ultra Hvdronic Models MO'd1jlf$'Uffi~~ 'Descnvtiop, . ,:-: ".. .... GWxxO-x-Uxxx .';.,. Standard, No Desuperheater GWxxl-x;,;Uxxxi.:,..'. Desuperheater GWxxx"l-Urix i; Standard, 208/230-1, 60 Hz GWrix-2-Uxxx'jx: 208/230-3,60 Hz GWxxx"3"Uxxx 460-3, 60 Hz 'GWx;xx~4~Uiii;i~"ft.., 220/240-1, 50 Hz 'GWxxx"9~Uxxi">i;f" 380-3, 50Hz GWxx.'t-A;;U;xxx" 200/220-3, 50Hz 'GWxxx-x:-UxOx"h, Standard Hydronic GWxxx-x~UxHx,;;:: Heat Only Hydronic GWxxx~x-UxTx', Staged Tandem Compressors GWx:xx~x-UxUx:';': Staged Tandem Heat Only GWrix-x"UxxO.\:: Standard Ground Loop Coil . 'GWxxX'~x~UxxN <, Cuoro-Nickel Well Water Coil .. ,GWxxx-x-UxxP .....',... Cupro-Nickel Hydronic Coil .. GWxxx-x-UxxV .' Cupro-Nickel Well Water and Hydronic Coil * 'Brazed Plate Ground Loop Heat Exchanger . Standard * Special Order Electrical Data , RL'A:'~::''&LRA~'''( ~;FtA;;";', P'f[; 370/371,.., .;, 208/230-1 17.1 83.0 3,6 -- 470/471" 208/230-1 25,7 134 3,6 -- 570/571 2081230-1 33,6 158 3.6 -- ,770/771 208/230-1 35.7 148 3.6 .- '. 870/871 208/230-1 32.1 185 3.6 -. , 1100/1101 208/230-3 33,6 225 -- -- 2400/2401 208/230.3 33.3 x 2 239 x 2 .. .- 2 ~~03'i;j"f~~f4t0~ ~1~:57j!iJ ';1J\77'!Jl \~187ii t1.lfiott ~~241)\4 . . . . . . . * * * .. * * . . . . .. * .. * . . * * * .. * * * * * * * .. * * * * * * * * * . . . . . . .. * .. * * * . * .1 .1 .1 .1 .1 .1 * .. * * * * .. * * * . * * * * * . * WithoutPulI1 ;PAKl~~i,;,~;~! ;;;i:J;~~5~_ 20.7 25.0 40 3.6 .... 24.3 28.6 45 29.3 35.7 60 3.6 -- 32.9 39.3 65 37.2 45.6 75 3.6 .- 40,8 49.2 80 39.3 48.2 80 3.6 -- 42.9 51.8 80 35.7 43.7 75 3,6 -- 39.3 47.3 75 33.6 42 75 -. .. -. -- -- 66.6 74.9 105 -- -- -- -- -- *HACR-aype breal.:er per NEe Physical Dimensions - GeoSource Ultra Hydronic Models ~ Acc;ess Panel o.ea" Ola. Knockouls In tlom Ground Loop Out to Ground Loop GW 87 Series 21.0" In from Ground Loop Oulto Hydronlc Access Panel 0.88" Dla. Knockouts M9,del~~Ifi~lm~~J ~li~Inletsr,~* ~,()titlet$~ GW(31-77)x:~-UXXX':) 1.00 FPT 1.00 FPT GW1I0x~x~UXxi,' ".)t;: 1.25 :rvlPT 1.25 MPT GW240x-x-Uxxx "''it' 2.00 MPT 2.00 MPT GW 110, 240 Series ~~ 30" 61" 42" f 0.88" Cia. Knockouts 1 Access Panel In (From Ground Loop) 3 Hydron~c Contro~ System I I I I 001 00 I Y E \>12 I I mJ -R x x Blue ASC @ Contro~~Qr o _6 XI PA FI? -<!ll LP I F.I? liP Hydronic Pump 1/3 HP MAX 230 Vol ts I I I I I I I I I II L IL_ L_ BP Red GROUND II. Green Blue Yell ow Hydron1c Heat Pump Electr"ical Diagram Rev L 7/06 BO-0011 Oesuper~eater Pump Factory Low Voltag'e Optional Jractory Linfiil Vo~t.aqe _ _ _ _ _ FiQd Low Vo~taqe Field Line Voltage I -l !o ~me.K .i2Pt.!2.na.ll. .-1 COIlPRESSOfl Legend BP B~ock, Pump DO Dry Contact Output F~ Fuse, Transformer F2 Fuse, Desuperheater FP Freeze Protection HL High-Temp Limit HP High Pressure Switch LP Low Pressure Switch Ml Contactor PA Plug, Accessory SA Start Assist (SOIDe Single Phase Models) 51? spare FUse VR Valve, Reversing Jl Remove ;l;or Rydron.ic J2 Ties w2 to E J3 OVerflow protection Wiring Diagram, Hydronic Models [G\Vxxxx-x-Uxxx 4 Hyd1:onic Control Sys talll pump 1/3 HP MAX Red ASe $ Ground ~ r--- Bll,e 3.Phase I ....~;:;G;- Black I I --- ue I '" Blue XI PA FP [Q:oJ - (f) Black ~ Reil u e Blue LP/FP liP ""'...... """'E>SGtI Fac to.r:t tow Vol taqs Factory Line Voltage FiQld Low Voltage g.il;llld Lina Vo~ tag_ Legend BP Block. Pump IlO Dry Contact Output Fl Fuse. TransforJlll!r FP Freeze Protection liP lIign.Prass Switch lP low-Press Switch }l1 Contactor PA Plug, Accessory RP Relay. Pump SA Start Assi st (For Single Phase Hodels) SP Spare Fuse VR Valve. Reversing Jl RellOve for HydrOl1ic J2 nes WZ to E J3 Overflow Prot. ~r~~~~1~a ~C8~ a:~: Rev C 7/06 80.0029 (IIIlPR(S"" CtWlESlOll Siltg'le Itnso '''Viring Diagram, Hydronic Models [GWx."'{xx-x-UxOx 5 Hydron.ic Control System ASe lD XI Blue Yell()'~ PA [QQ] Fl? -0 Black LP / FJ} HP J1yd1'onic lieat PUllP Electr1cal Oiogrll<l Rev 0 7106 80.0026 Legend BP Sleck. Pump 00 Dry Contact Relay Fl Fuse. Transformer F2 Fuse. Oesuperheater FP Freeze Protection HP Hi sh. Pressure 5191 tcn HL Hgh TeIlp Lfm1t lP low. Pressure S\fltch H1 Contador PA Pl ug. Accessory RP Relay. PL'llIfl SA Start Assist (For 51ngle Phase HodeU) S? Spare fUSe VR Valve. Reversing J1 Rerr.ove for Hydronlc J2 Ties W2 to E J3 OverflOll Protect1on ---- Faet;o~J Low Voltfig-G _ Fa.ctory Line VoltagQ _ _ Fi.ald (.ow Vo~tagQ _ _ ria..ld L.i.ne Voltage Pump 1/3 HP MAX 1'1 III SP 111.!;d I L ~en I_B~k White Black 208V Top Yellow Red GROIJIID GROUND ~ Black r--- 3. Phase I r- p";;..";" I ,--- Blue Black ue en Yellow Red ( I I I I I I am!>S<.l! I I ~ I LbO-ttI- -- cmllWCIl Oesuperheater Pump Optional (field Installed) H1 COII'llru<lll S1111Jle Ph... ""'WSCIl "Viring Diagram, Hydronic Models [GWxxxx-x-UxTx 6 Output Capacity H dronic Ultra Ground Side Flow Rates W~,W:itEAtING~*;"%\ :0t~i!;COOLING:~i!i ?~B111/1ir:lt IXW'~ '~m11iltif':;i:~kw~ 0,90 0,97 0.97 1.05 0.91 0.97 0.97 1.05 0.92 0.98 0.98 1.04 0.93 0.98 0.98 1.04 0.94 0.98 0.98 1.03 0.96 0.99 0.99 1.02 0.98 0.99 0.99 1.01 1.00 1.00 1.00 1.00 1.02 1.00 1.01 0.99 1.04 1.00 1.02 0.98 1.06 1.01 1.02 0.98 1.07 1.01 1.03 0.97 j .-x1.:.;-.:. ,.:::~~~~\;~> 1.08 1.02 -1.03 0.96 "Vater Coil Pressure Drop Ratings (pure 'Water) Correction Factors dronic Ultra H dronic Side Flow Rates ~~~IfE*'rING",~~~ '~CO()r;.ING!;W:i,; tltBTUlh'i1:'J ~~kwfi ''%Btli/li~:~i i(;KW;:(i 1.00 1.00 1.00 1.00 1.01 0.98 1.03 1.01 1.02 0.96 1.06 1.02 1.03 0.95 1.08 1.03 1.04 0.94 1.09 1.04 1.05 0.94 1.10 1.05 Hydr~,~~~,i;;' .,GroundSid:e , Hd~Side -:~~~1tf81!'t,t~ i~~~f !'h~~t! j~~:ij ~~~:~' 2 0.9 3 0.9 3 0.9 4 1.5 GW37* 4 1.3 5 1.7 5 1. 7 6 2.8 6 2.8 7 4.7 7 4.7 8 5.5 9 6.5 10 7.8 Hydr?nic ;:jGroundSide', H d. Side ~~~~~f~'l~ti~?'T~ ~~;~ ~~.~.~~~ ]~~~. ':~?:~Wt 6 1.6 7 4.8 7 2.0 8 6.0 GW 57* 8 2.5 9 7.0 9 3.1 10 10.0 10 3.8 [] 11.7 11 4.3 12 4.8 13 6.0 14 7.5 15 9.4 Hydr?o.,~c:.c GroundSide... H d..8ide ~~6~aJr;y,';;tt~?i ')r;;:r\'~'~~', j~~:i~ .~~:~~~ 14 2.7 14 3.9 16 3.0 16 4.2 GW87* 18 3.3 18 4.5 GWllOO* 20 3.5 20 4.9 22 3.8 22 5.3 24 4.1 26 4.5 28 4.8 30 5.2 4 0.8 5 2.6 40 2.4 28 1.6 5 1.2 6 3.0 8 3.0 9 7.0 44 2.9 32 1.7 GW 47* 6 1.6 7 4.8 9 3.5 10 10.0 GW2400* 48 3.5 36 1.9 7 2.4 8 6.0 GW 77* 10 3.8 II 11.7 52 4.1 40 2.4 8 2.8 9 7.0 II 4.6 12 14.7 56 4.7 44 2.9 9 3.6 12 5.3 13 17.0 60 5.4 48 3.4 10 4.4 13 6.1 64 6.2 52 4.0 11 5.2 14 7.0 68 7.0 56 4.6 12 6.4 15 7.9 72 7.8 60 5.3 13 7.6 16 9.0 76 8.7 64 6.1 · Ground Loop Pressure Drops apply to standard water coils only. Cupro-nickel water coils have higher pressure drops. 7 ECONARID l'l,r'~~b~~ GeoSOllrce~ 2000, DllaITEK, Vara, Vara 2 PIUS™, Invision3, and Ultra Heat Pumps USA and Canada Residential and Limited Commercial Warranty** Residential Applications Only: All Parts - 2 Years Years 1 through 2, ECONAR Energy Systems Corp. will provide a free replacement part upon prepaid return of all defective parts, F.O.B. Appleton, MN for any part which fails to function properly due to defective material, or workmanship. * During this period, ECONAR will cover cost of labor for the replacement of parts found to be defective; not to exceed ECONAR's published Labor Rate Schedule. Refrigeration Components - 5 Years Years 3 through 5, ECONAR will provide a free relacement part F.O.B. upon prepaid return of defective parts, F.O.B. Appleton, MN for any compressor, or refrigeration components (parts only***) which fails to function properly due to defective material or workmanship. Heat Exchangers - Lifetime ECONAR will provide a free replacement internal heat exchanger (i.e. water to refrigerant, refrigerant to air) upon prepaid return of defective part F.O.B. Appleton, MN (parts only) for the lifetime of the heat pump. Commercial Applications Only: All Parts - 1 Year **First year, ECONAR will provide a free replacement upon prepaid return of all defective parts, F.O.B. Appleton, MN for any part which fails to function properly due to defective material or workmanship. During this period, ECONAR will cover the cost of labor for the replacement of parts found to be defective; not to exceed ECONAR's published Labor Schedule. Refrigeration Components - 5 Years Years 2 through 5, ECONAR will provide a free replacement part upon prepaid return F.O.B. Appleton, MN for any compressor, or refrigerant component (parts only) which fails to function properly due to defective material, or workmanship. All Applications: Limitations: . Begins the date of original purchase as recorded by ECONAR with the return ofthe warranty registration card. (If warranty card is not submitted, warranty begins the date of original manufacture based on serial number). · Applies to original installation and normal use of the heat pump only and does not include any other component of a system as a whole. · All ECONAR labeled and manufactured accessories carry a 2 year part warranty for residential duty and I year for commerical duty. All other accessories carry the manufacturers warranty only. Labor is excluded on all accessories. . Service must be performed by an ECONAR authorized service person. . Replacement parts shall be warranted for the remaining warranty of the unit. · Under no circumstances will ECONAR be liable for incidental, or consequential expenses, losses or damages. Owners Responsibilites: . Return warranty card to activate warranty coverage. See form #90-0147 . Provide normal care and Maintenance. · Make products accessible for service. 'Varranty is Void if: . Data label is defaced, or removed. · Product has defect, or damage due to product alterations, connection to an improper electric supply, shipping and handling, accident, fIre, flood, lightning, act of God, or other conditions beyond the control ofECONAR. · Products are not installed in accordance with ECONAR instructions and specifIcations. . Products which have defects, or insuffIcient performance as a result of insuffIcient or incorrect installations; poor water supply, design, or the improper application of products. (This would include a freeze rupture) . Products are installed, or operate in a corrosive environment causing deterioration of metal parts. 'Warranty Performance: · The installing contractor will provide the warranty service for the owner. If the installing contractor is not available, contact: ECONAR Energy Systems, Corp., Customer Support, at 33 West Veum, Appleton, MN 56208 or call toll free 1-800-4-ECONAR. *Determination of the defect is the sole discretion of ECONAR Energy Systems, Corp. **Limited Commercial Warranty covel's all non-residential applications. ***Energy Stm' rated products include parts and labor. This warranty supersedes any and aU previously written or implied warranty documentation. @ECONAREnergy Systems Corporation 12103 8 @t.- @1 Preliminary 20061004_01 ColdClimate ™ Geothermal Heat Pumps ECOIAR@ ltr~It1~rgfrb~if~~ 19230 Evans Street (Hwy 169) Elk River, MN 55330 USA 1-800-4-ECONAR www.econar.com p--- \J Q ~oo. A International Ground Source Heat Pump Association GEOEXCHANGE :"~':"Ir<["r...~J'r''''''' w. Selllhating "CIXIIIl9 Equlpmllnt wiIhIhlEMe1lGvSrAJ(L,ggo. ltleSymllol101 &lergyEtRc:ency. @ ECONAR Energy Systems Corp. 9 :t' 'i:~ ECONAR~ [(.r.r.)]~rg:frb=~ GeoSource@ 2000, DualTE](, Vara, Vane 2 Plus™, InvisiOll and Ultra Heat Pumps USA and Canada Residential and Limited Commercial Warrallty** Residential Applications Only: All Parts - 2 Years Years I and 2, ECONAR Energy Systems Corp. will provide a free replacement part upon prepaid return of all defcctive parts, F.O.B. Appleton, MN for any part which fails to function properly due to defective material, or workmanship. * During this period, ECONAR will cover cost of labor for the replacement of parts found to be defective: not to exceed ECONAR's published Labor Rate Schedule. Refrigeration Components - 5 Years Years 3 through 5, ECONAR will provide a free relacement part upon prepaid return of defective parts, F.O.B. Appleton, MN for any compressor, or refrigeration components (parts only***) which fails to function propcrly duc to defective material or workmanship. Heat Exchangers - Lifetime ECONAR will provide a free replacement internal heat exchanger (i.e. warer to refrigerant, refrigerant to air) upon prepaid return of defective part F.O.B. Appleton, MN (parts only) for the lifetime of the heat pump. Commercial Applications Only: All Parts -1 Year **First year, ECONAR will provide a free replacement upon prepaid return of all defective parts, F.O.B. Appleton, MN for any part which fai Is to function properly due to defective material or workmanship. During this period, ECONAR will cover the cost of labor for the replacement of parts found to be defective; not to exceed ECONAR's published Labor Schedule. Refrigeration Components - 5 Years Years 2 through 5, ECONAR will provide a free replaccment part upon prepaid return F.O.B. Appleton, MN for any compressor, or refrigerant component (parts only) which fails to function properly due to defective material, or workmanship. All Applications: Limitations: . Begins the date of original purchase as recorded by ECONAR with the retum of the walTmllY registration card. (If warranty card is not submitted, warranty begins the date of original manufacture based on serial number). Applies to original installation and nonnuluse. of the heat pump only and docs not include any other component of a system as a whole. All ECONAR labeled and manufactured accessories ean'y a 2 year pali warranty for residential duty and I year for commerical duty. All other accessories carry the manufacturers warranty only. Labor is excluded on all accessories. Service must be performed by an ECONAR authorized service person. Replacement parts shall be warranted for 90 days. After the 90 days, the parts will be covered by the remaining warranty of the unit. Undcr no circumstances will ECOi\AR be liable for incidental, or consequential expenses. losses or damages. Owners Responsibilites: . Return warranty card to activate warranty coverage. See form #90-0147 . Provide normal care and maintenance. Make products accessible for service. Warranty is Void if: Data label is defaced, or removed. Product has defect, or damage due to product alterations, connection to an improper electric supply, shipping and handling, accident. fire. flood, lightning, act of God, or other conditions beyond the control of ECONAR. Products are not installed in accordance with ECONAR instructions and specifications. Products which have dcfects. or insufficient performance as a result of insufficient or incon'ecl installations, poor water supply, design. or the improper application of products. (This would include a freeze rupture) Products are installed, or operate in a corrosive environment causing deterioration of metal parts. 'Warranty Performance: ~ The installing contractor will provide the warranty service for the owner. If the installing contractor is not available, contact: ECONAR Energy Systems, Corporation Customer Support at: 33 West Veum, Appleton, MN 56208 or call toll free 1-800-4-ECONAR. *Determination oJthe defect is Ifle sole discretion o/ECONAR Energy Systems. Corp. **Limited Commercial Warranty covers allnon-residelllial applications. ***Energy Star ra/ed products include parts and lahor This warramy supersedes any and all previously "'Titten or implied warranty documentation. r=h @ECONAR Energy Systems Corporation 03/2006 rF -