Loading...
5.5. SR 03-12-2007 Eft( -- River City of Elk River REQUEST FOR COUNCIL ACTION Agenda Section Meeting Date Worksession March 12, 2007 Item Description YMCA U date Item Number 5.5. Prepared by Lori ohnson, Ci Administrator Reviewed by Introduction The YMCA project is proceeding on several fronts; the attorneys are working on the lease, city staff is working on coordinating all of the site issues for the conditional use permit and plat, and YMCA representatives, city staff, and the architects continue to work on the building design. I will give an update on these items at the meeting. Discussion LEASE: Steve Bubul of Kennedy & Graven has drafted a lease between the EDA and YMCA, with consent by the City, for the construction and operation of the YMCA. Peter Beck and I reviewed the document with Mr. Bubullast week and provided comments and changes. We expect a version for distribution to the YMCA within the next week. It will be provided to the Council and EDA for review before adoption. SITE AND RELATED ISSUES: Parks and Recreation Director Bill Maertz and Community Development Director Scott Clark have been working with engineering and planning to address the site items for this project. A plat will be coming forward to designate the parcel boundaries for the property that will be leased to the YMCA, along with a conditional use permit (CUP). These items are running concurrently with the architect's work on building design. BUILDING DESIGN: Greg Fenton of BWBR Architects is leading the team to program and design the building. Representatives from the YMCA, city staff, and BWBR have been meering weekly for the last month developing the program spaces, reviewing site layout, exterior design, and other building features. Representatives of the YMCA have also suggested that an alternate method of bidding the project be considered since the Council did not approve the use of a construction manager. Peter Beck and Steve Bubul are currently researching the proposed concept to ensure that it meets all of the city's bidding requirements. I should have a response to this question before Monday's meeting along with more details about the proposal. Councilmember Gumphrey met with YMCA representatives to discuss their proposal so he will also be able to provide information on the proposal. S:\Council\Lori\2007\ YMCA Update 03 12 07.doc FinanciallmDact Attachments . Draft Space Program dated February 13, 2007 Action Reauested At this time, no action requested. This is an update only. If information on the alternate bidding process is available at Monday's meeting, the Council may choose to take action on how to proceed with that portion of this project. Council Action Motion by_ Second by _ Vote_ Follow Up S:\Council\Lori\2007\ YMCA Update 03 12 07.doc Elk River, Minnesota '@~~1f1 Space Program First Draft February 13,2007 Commission Number 2007.024.00 ~~ ,~w,a R. "t,. A RCHff'Ec-ts " .", .....-.. ~""'p Space Program for Elk River YMCA <!l~ INTRODUCTION .~@h~ 0\\$ 'V SITE PLANNING CRITERIA ~ ARCHITECTURAL DESIGN CRITERIA SPACE PROGRAM SUMMARY DETAILED SPACE DESCRIPTIONS . GYMNASIUM . FITNESS STUDIO I . FITNESS STUDIO II . FITNESS AREA . GYM STORAGE . AQUATICS . POOL STORAGE . POOL FILTER/EQUIPMENT ROOM . ADULT LOCKER ROOMS . LOBBY . F AMIL Y /SPECIAL NEEDS LOCKERS . COMMUNITY ROOM . ADMINISTRATION . CONTROL DESK/LAUNDRY . KID'S ZONE/CHILD CARE/yOUTH AREA Commission No. 2007.024.00 INDEX , PAGE 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 SPACE PROGRAM FOR ELK RIVER YMCA INTRODUCTION ~ This Program outlines BWBR's understanding and interpretation of the design criteria and space needs for the Elk River YMCA. Design criteria are delineated as a design guide fo-i{p.e architectural planning for this projects, and includes both architectural and site planning c~~. ..<:; '<'// The architectural Space Allocation prog.ram\;i;~mPilatiOn of both net usable and gross square foot areas. Net usable area is programm'('l"~~ ~;ndjvidual space in the building, and is based on activities, number of participants,,_~tl4',_ Ired equipment. Gross area is an estimate of space required for wall thicknesses, mee1tani~' room and duct s.paces, internal circulation, and structural considerations. For this building, we.>have applied a gross-up factor or 1.15 x net area, based on industry standards, coupled with our experience on similar buildings. Also included in this Program is a written summary of functional requirements for each space, along with an accompanying planning diagram. 2 SPACE PROGRAM FOR ELK RIVER YMCA SITE PLANNING CRITERIA I D Provide access from Orono Drive. D Project visibility from Highway 10. D Provide parking for 275 cars (based on similar existing facilities). D Provide a drop-off zone at the front entry. o Solar' access to entries is important. D Provide service entry separate from front door. Access from water tower access drive. D Provide bike parking/racks (15-20 bikes) o Provide for pedestrian access. Even though there is not a l'idewalk network in place, there is potential for pedestrian traffic from residences and busine~ses. D Provide outdoor playground adjacent to Kids Zone. o Utilize lsustainable site design to great extent (i.e. storm wa.ter management, landscape plantings, irrigation, etc.). D Provide future parking ability that is convenient for City Park, ball fields, and YMCA growth. D Project team identified layout criteria discovered in planning workshop. . Gym 'building' to north side of site. Entry facing west to parking. Kids Zone program component has high visibility upon entering site. Building is 'centered' in site to allow future expansion of building and parking. Pool to have southern: controlled, exposure. Provide green connection to lake for programs. . . . . . 3 SPACE PROGRAM FOR ELK RIVER YMCA ARCHITECTURAL DESIGN CRITERIA I o Room to move and grow - flexibility and expand.bility. o Build a lasting and qu.lity image. o Efficient staffing through efficient layout! design. 1:1 A safe and fun place to be. o Flexibility - spaces should be designed to accommodate multiple functions where possible, and also should permit adaptation in the future. 1:1 Durabilit}' - finishes must be selected to withstand heavy use with minimal maintenance. 1:1 Buildings construction shall incorporate a large quantity and diverse range of high recycled content materials. Building should serve as a 'model' community building in regards to sustainability. o Visibility - provide views into activity spaces from entrance -area as a means of "marketing" programs and activities to users and potential members. Also enhances security and supervision in building. o Zone activities to provide separation of kids and adults. Q Create an environment where people want to spend rime. o Entry should be warm, inviting, and animated, with views into other activity areas. o Provide views into activity areas as you approach the building from parking areas. Q Organize spaces to minimize circulation space. o Provide propet building access control for. this joint partner partially shared project. 4 SPACE PROGRAM FOR ELK RIVER YMCA SPACE PROGRAM SUMMARY I SU1IJ)Ort Spaces Sqpare Feet Gym (Two Courts 75 x 108) Fitness Studio I/Storage Fitness Studio II/Storage Fitness Area Gym Storage Kid', Zone/Child Care/Youth Area Aquatics 4 lanes + leisure pool Pool Storage Pool Filter/Equipment Room Locker Rooms (2) @ 2,200 SF ea. Lobby Family/Special Need Lockers rJ) Community Room/Kitchenette Administration Control Desk/Laundry Mechanical Equipment Space Outdoot Equipment Storage/Maintenance Electrical/Telephone Elevator & Elevator Equipment Space Pu blic Toilets Men's 2 fixtures, 200 SF Women's 3 fixtures, 240 SF 8,100 2,560 1,720 9,000 400 4,200 8,500 300 460 4,400 2,000 1,100 2,200 2,200 500 2,000 1,000 140 130 -11Q Total Net Area Net/Gross Multiplier Total Gross Area 51,350 x 1.15 59,052 5 SPACE PROGRAM FOR ELK RIVER YMCA DETAILED SPACE DESCRIPTIONS I The following pages illustrate BWBR's understanding of detailed space requirements for the major occupied program spaces in the Elk River YMCA. 6 SPACE PROGRAM FOR ELK RIVER YMCA GYM I DIMENSIONS: Approximately 75' x 108' SQUARE FEET: OCCUPANTS: 150 (Code: 540 @15/s.f. Net) 8,10(} SPACE FUNCTION: Basketball, Volleyball, Kids Activities, Badminton, Youth Sports SPECIAL CONSIDERATIONS: Key switched electrical curtain to divide in half; windows located so not to produce glare. EQUIPMENT REQUIREMENTS: Moveable double row bleachers for half basketball court, length to seat 60. Electrical basketball backstops, manually adjustable height; scoreboards for each half court; wall padding. ACCESS/ ADJACENCY NEEDS: Shared partner storage adjacent with two sets of double doors (see Gym Storage). FLOOR FIN: Hardwood cushioned FLOOR LOAD: WALL FIN: Painted or burnished block BASE: Veored at wood flooring CEILING FIN: Exposed, painted CEILING HEIGHT: 24' to bottom of strucrure ACOUSTICAL REQUIREMENTS: Sound system acoustical treatment at ceiling, some t.reatment on walls ELECTRICAL POWER: Power on walls LIGHTING: Staff controlled, M.LD. FOOT CANDLES: 50 FC, uniform (BFS) TELEPHONE: --- COMMUNICATION: Via paging system SECURITY: Local alarm door hardware at enerior exits CONTROLS: SOUND: HV AC: 6/8 air changes/hour with minimum outside air (BFS) PLUMBING: Cuspidor/water cooler OTHER: Protective guards on fixtures, sprinklers, life safety devices, etc. Emergency call button easily accessed; clock. Origination Date: 2/06/07 Modification Date: 7 SPACE PROGRAM FOR ELK RIVER YMCA DIMENSIONS: 40' x 60' SPACE FUNCTION: Group exercise, older adult exercise, Specialty exercise SPECIAL CONSIDERATIONS: Portable 8" platform storage of steps within space EQUIPMENT REQUIREMENTS: Sound system - Speakers Ceiling fans ACCESS/ADJACENCY NEEDS: Visible from corridor Small storage lockers outside room; storage room 8' x 20'fo< equipment FLOOR FIN: Cushioned wood WALL FIN: Mirrors on long waU at front and sidewaU CEILING FIN: Acoustic ceiling tile l\COUSTICAL REQUIREMENTS: Sound system for music, c.n. and cassette~ in closet, wall mounted speakers FITNESS STUDIO I I SQUARE FEET: 2,400 + 160 s.f. storage occur ANTS: 40 - 45 (Code: 48 @ 50 s.f./gross) FLOOR LOAD: BASE: CEILING HEIGHT: 10' + ELECTRICAL POWER: LIGHTING: 2-1evel fluorescent and recessed incandescent) local s'Witching FOOT CANDLES: 50 FC, uniform, 30 FC variable to TELEPHONE: . COMMUNICATION: SECURITY: CONTROLS: SOUND; See above HV AC: 6-8 air changes/hour PLUMBING: Electric drinking fountain outside room OTHER: Origination Date: 2/6/07 Modification Date: 8 SPACE PROGRAM FOR ELK RIVER YMCA FITNESS STUDIO II ~ DIMENSIONS: 32' x 50' SQUARE FEET: 1,600 + 120 d. storage SPACE FUNCTION: Group exercise, older adult exercise, Specialty exercise OCCUPANTS, Classes of25 - 32 (Code: 32@ 50 s.f/gross) SPECIAL CONSIDERATIONS: Portable 8" platform storage of steps within space EQUIPMENT REQUIREMENTS: Sound system - Speakers, Ceiling fans ACCESS/ADJACENCY NEEDS: Visible from corridor Small stonge lockers outside room; storage room (8'x16') for equipment FWOR FIN: Cushioned wood/ Altemate(?) FLOOR LOAD: WALL FIN: Mirrors on long wall at front and sidewall BJ\SE: CEILING FIN: Acoustic ceiling tile CEILING HEIGHT: to' + ACOUSTICAL REQUIREMENTS: Sound system for music in loeb.bIe equipment cabinet, wall mounted speakers ELECTRICAL POWER: LIGHTING: 2-level fluorescent and incandcscent (dimmable), local switchlllg FOOT CANDLES: 50 FC, uniform, 30 FC variable to TELEPHONE: Yes COMMUNICATION: SECURITY: CONTROLS: SOUND: See above I-N AC: 6-8 air changes/hour PLUMBING: Electric drinking fouotain outside room OTHER: Origination Date- 2/6/07 Modification Date: 9 SPACE PROGRAM FOR ELK RIVER YMCA DIMENSIONS: TED SPACE FUNCTION:, Cardiovascular Fitness Resis.tance Fitness Training Strength Training SPECIAL CONSIDERATIONS: EQUIPMENT REQUIREMENTS: Sound system - Wall mounted TV's ACCESS/ ADJACENCY NEEDS: View of pool ideal; views to outside or other activity areas) fitness testing room (lO'x12'), storage (10'xlS'), equipment repair (10'xlS'), fitness staff office (1O'x12') FLOOR FIN: Rubber at machine, interlocking rubber at free weigh ts WALL FIN: Mirrors a t free weigh ts CEILING FIN: Ceiling tile; exposed structure ACOUSTICAL REQUIREMENTS: FITNESS AREA I SQUARE FEET: 9,000 OCCUPANTS: 60/70 s.f./Occupant (Code: 180 @ 50 GSF /Occupant) FLOOR LOAD: B.\SE: CEILING HEIGHT: 10' minimum ELECTRICAL PO\X1ER: About 1/2 equipment needs power, some 220 V. Dedicated circuit, recessed floor boxes with data capability, LIGHTING: Fluorescent FOOT CANDLES: 50 f/ c uniform coverage TELEPHONE: Yes COMMUNICATION: SECURITY: CONTROLS: Sensors SOUND: Ceiling HV AC: Perceptible air movement, 6-8 air changes/hour PLUMBING: Drinking fountain, in space OTHER: Emergency call button, docks Origination Date: 2/6/07 Modification Datc: 10 SPACE PROGRAM FOR ELK RIVER YMCA DIMENSIONS: 12 x 32 SPACE FUNCTION: Storage for large gym SPECIAL CONSIDERATIONS: Bins for ball storage, pair of doors into gym EQUll'MENT REQUIREMENTS: Storage equipment by owner ACCESS! ADJACENCY NEEDS: Open directly into gym FLOOR FIN: Concrete WALL FIN: Concrete block - unpainted CEILING FIN: Exposed ACOUSTICAL REQUIREMENTS: N! A ELECTRICAL POWER: LIGHTING: Fluorescent FOOT CANDLES: TELEPHONE: m COMMUNICATION: SECURITY: --- CONTROLS: m SOUND: HV AC: :tvfinimurn to condition space PLUMBING: 'n OTHER: no Origination Date: 2!06!07 Modification Date: GYM STORAGE I SQUARE FEET: . 400 OCCUPANTS: o FLOOR LOAD: BJ\SE: CEILING HEIGHT: Minimum 10' 11 SPACE PROGRAM FOR ELK RIVER YMCA DIMENSIONS: TED SPACE FUNCTION: Lap pool, Recreational pool, Spa - used for fitness, training, and family recreation SPECIAL CONSIDERATIONS: EQUIPMENT REQUIREMENTS: Per State Code. Lifeguard chairs, life safety, and first aid equipment, tamp into pool. ACCESS/ ADJACENCY NEEDS: Visible from main entry a must. Also immediately adjacent to locker rooms. Pool storage (300 SI') adjacent. Aquatics program office (120 SF).adjacent. (1) unisex toilet room - access from pool deck. FLOOR FIN: Ceramic tile WALL FIN:. Epoxy painted masonry or glazed CEILING PIN: TED ACOUSTICAL REQUIREMENTS: Sound deadening required ELECTRICAL POWER: None in pool area LIGHTING: At perimeter, plus underwater lighting FOOT CANDLES: TELEPHONE: Emergency phone COMMUNICATION: PA/sound system SECURITY: CONTROLS: SOUND: HVAC: PLUMBING: Drinking fountain, shower in space OTHER: Emergency call button Origination Date: 2/05/07 Modification Date: AQUATICS I SQUARE FEET: 8,000 OCCUPANTS: Estimate of 200 (pool Code: 1 occupant/15 s.f. of water) FLOOR LOAD: BASE: CEILING HEIGHT: TED 12 SPACE PROGRAM FOR ELK RIVER YMCA DIMENSIONS: 15' X 20' SPACE FUNCTION: Storage for kick boards, life jackets, lane dividers, instructional aids. SPECIAL CONSIDERATIONS: Pair 3'-0" x 7'-0" doors, mmllnum EQUIPMENT REQUIREMENTS: ACCESS/ADJACENCY NEEDS: Open directly to pool deck FLOOR FIN: Concretelsealer WALL FIN: Painted concrete ~asonry CEiLING FIN: None ACOUSTICAL REQUIREMENTS: None ELECTRICAL POWER: LIGHTING: Fluorescent FOOT CANDLES: TELEPHONE: --- COMMUNICATION: m SECURITY: --- CONTROLS: --- SOUND: --- HV AC: Served by pool unit PLUMBING: m OTHER: --- Origination Date: 2/06/07 Modification Date: POOL STORAGE ~ SQUARE FEET: 300 occur ANTS: N/A FIDOR LOAD: BASE: CEILING HEIGHT: Minimum 10' 13 SPACE PROGRAM FOR ELK RIVER YMCA POOL FILTER/EQUIPMENT ROOM I DIMENSIONS: 23' x 20', TED SQUARE FEET: OCCUPANTS: 460 SPACE FUNCTION: Pool filter systems, pumps, valves~cheinical feeders o SPECIAL CONSIDERATIONS: EQUIPMENT REQUIREMENTS: SeIVices determined by Aquatics design ACCESS/ADJACENCY NEEDS: FLOOR FIN: FLOOR LOAD: WALL FIN: Exposed material BASE: CEILING FIN: Exposed material CEILING HEIGHT: Minimum 9' ACOUSTICAL REQUIREMENTS: N/ A ELECTRICAL POWER: Per equipment LIGHTING: FOOT CANDLES: TELEPHONE: COMMUNICATION: SECURITY: CONTROLS: SOUND: HV AC: SeIVed by building (not pool) HV AC unit. PLUMBING: OTHER: Origination Date: 2/06/07 ModifiCation Date: 14 SPACE PROGRAM FOR ELK RIVER YMCA ADULT LOCKER ROOMS I DIMENSIONS: TBD SQUARE FEET: (2) 2,200 SPACE FUNCTION: Male and female lockers/dressing, showers, wet and dry toilets, and sauna (off of Aquatics) OCCUPANTS: <50 (Code: 44, 50 GSF / occupant) SPECIAL CONSIDERATIONS: Layout to meet state pool code. Women's showers to have stalls using plastic partition material. EQUIPMENT REQUIREMENTS: Lockers and stools, (no benches), Wall mounted electric hand dryers for hair at lay area, scale, mirrors Lockers to be high density polyethylene (no metal lockers) ACCESS/ADJACENCY NEEDS: Direct access to pool from showers, convenient to other fitness programs FLOOR FIN: Carpet at dressing areas(with rubber flooring runners?) ceramic tile (1xI) at toilets, showers, dark floor grout FLOOR LOAD: WALL FIN: Painted masonry, 4" x 4" wall tile in wet areas BJ\SE: CEILING FIN: Ceiling tile/plaster (or EIFS?) CEILING HEIGHT: 9' OTHER FINISHES: Counters - solid surface ACOUSTICAL REQUIREMENTS: Acoustic ceiling with aluminum suspension system ELECTRICAL POWER: At Iav area, grooming stations LIGHTING: FOOT CANDLES: 50 fie minimum, uniform TELEPHONE: COMMUNICATION: SECURITY: CONTROLS: SOUND: Connection to paging system HV AC: Return ventilation begins in wet spaces PLU1vfBING: Showers, toilets,lavs - exposed chases for access, faucets (Delta), water cooler in each room; provide hose bib to clean shower areas. OTHER: Origination Date: 2/06/07 Modification Date: 15 SPACE PROGRAM FOR ELK RIVER YMCA DIMENSIONS: TED SPACE FUNCTION: Public entry, observation, circulation, display and exhibit, public toilets, gym office for city use. SPECIAL CONSIDERATIONS: Public phones, daylight, good visibility to activity zones, control of incoming air thru vestibule, vencling services. seats urith views to pool. EQUIPMENT REQUIREMENTS: Janitor closet ACCESS/ADJACENCY NEEDS: Adjacent to gym for access control management of gym. Team waiting area between gym and lobby. FLOOR FIN: Durable and cleanable WAll FLN: CEILING !'IN: ACOUSTICAL REQUIREMENTS: Control noise to other spaces ELECTRICAL POWER: LIGHTING: FOOT CANDLES: 50 f/c uniform TELEPHONE: COMMUNICATION: SECURITY: All - coordinated to control desk CONTROLS: SOUND: HVAC: PLUMBING: OTHER: Origination Date: 2/06/07 Modification Date: LOBBY I SQU,\RE FEET: 2,000 OCCUPANTS: 20 FLOOR LOAD: B,\SE: CEILING HEIGHT: Minimum 10' 16 SPACE PROGRAM FOR ELK RIVER YMCA DIMENSIONS: TBD SPACE FUNCTION: IJ) Individual changing rooms, all with lays and showers, (2) unisex toilet rooms SPECIAL CONSIDERATIONS: (2) Handicapped accessible EQUIPMENT REQUIREMENTS: Direct corridor to pool, (20) lockers outside changing rooms, grooming area with lays; bench/ towel hooks in rooms ACCESS/ADJACENCY NEEDS: Elevator FLOOR FIN: Similar to Locker Rooms WALL FIN: Similar to Locker Rooms CEILING FIN: Ceiling tile ACOUSTICAL REQUIREMENTS: ELECTRICAL POWER: LIGHTING: FOOT CANDLES: TELEPHONE: COMMUNICATION: SECURITY: CONTROLS: SOUND: HVAC: PLUMBING: OTHER: Origination Date: 2/06/07 Modification Date: FAMILY/SPECIAL NEEDS LOCKERS , SQUARE FEET: (Est) 1,100 OCCUPANTS: FLOOR LOAD: BASE: Ceramic Tile CElLING HEIGHT: Minimum 9'-6" 17 SPACE PROGRAM FOR ELK RIVER YMCA DIMENSIONS: 33' x 60' SPACE FUNCTION: Multiple use, large community meetings, over flow, aerobics, camp check-in, ete. SPECIAL CONSIDERATIONS: Acoustical isolation from Youth area. Movablc partitions (with high STC rating) for divisibility to two smaller rooms. Storage space in room for coats, tables and chairs. EQUIPMENT REQUIREMENTS: A/V capability, Project screens, TV monitors, window treatments KITCHENETTE: To serve as staff break area. Basel upper cabinets, refrigerator, coffee, dedicated wall receptacles for catering bins, dishwasher, double sink ACCESSI ADJACENCY NEEDS: Close to public entry lobby, kitchenette (200 s.f.), Kid's Zone with doors FLOOR FIN: Hardwood/tile/VCT(?) WALL FIN: Painted CEILING FIN: Ceiling tile ACOUSTICAL REQUIREMENTS: STC 40-50 to .djacentspaces ELECTRICAL POWER: LIGHTING: Indirect fluorescent. Dimmable incandescent. FOOT CANDLES: 50 - 100 fl c variable TELEPHONE: Yes COMMUNICATION: On p.ging system with conrrol switch SECURITY: CONTROLS: SOUND: Local sound system HVAC: PLUMBING: OTHER: Origination Date: 2/06/07 Modification Date: COMMUNITY ROOM I SQUARE FEET: 2,200 (Includes 200 s.f. kitchen) OCCUPANTS: (Code: 15 NSF I occupant=135) FLOOR LOAD: BASE: CEILING HEIGHT: 10' 18 SPACE PROGRAM FOR ELK RIVER YMCA ADMINISTRATION I DIMENSIONS: TBD SQUARE FEET: 2,200 SPACE FUNCTION: Staff offices; general open office for (8) stations; workroom with sink/copier/storage; small conference rooms for 8. OCCUPANTS: 14-20 SPECIAL CONSIDERATIONS: Office suite setting, two guest seats inside door EQUIPMENT REQUIREMENTS: PCs, copier, general office equipment ACCESS/ADJACENCY NEEDS: Close to public lobby, coffee and sink. Daylight and view from office areas, locate on fIrst floor to rear of building. FLOOR FIN: Carpet FLOOR LOAD: WALL FIN: Painted BASE: CEILING FIN: Acoustical tile CEILING )-IEIGHT: Minimum 9'-6" ACOUSTICAL REQUIREMENTS: STC 40-50 between offices and Conference Rooms ELECTRICAL POWER: LIGHTING: Fluorescent, indirect if affordable FOOT CANDLES: 50 f/c uniform, additional task lighting at workstation, TELEPHONE: COMMUNICATION: SECURITY: CONTROLS: SOUND: I1VAC: PLUMBING: OTHER: Origination Date: 2/06/07 Modification Date: 19 SPACE PROGRAM FOR ELK RIVER YMCA DIMENSIONS: TED SPACE FUNCTION: Control point for building access, equipment check-out, member materials; small office for member service; laundry with storage SPECIAL CONSIDERATIONS: Service counters. Display Counter, point of sale functions, check-in procedures, Membership photos EQUIPMENT REQUIREMENTS: 1. computer work station at each cQuota/ scanner at locker controL cash at Sports Shop. Laundry: 1 - commercial washer, 1 - commercial dryer, folding table, towel storage/carts. ACCESS! ADJACENCY NEEDS: Lobby FLOOR FIN: Carpet at desk area WALL FIN: CEILING FIN: ACOUSTICAL REQUIREMENTS: ELECTRICAL POWER: Per equipment LIGHTING: Both for function and aesthetic/inviting use FOOT CANDLES: TELEPHONE: COMMUNICATION: SECURITY: CONTROLS: SOUND: HVAC: PLUMBING: OTHER: Origination Date: 2/06!07 Modification Date: CONTROL DESK/LAUNDRY I SQUARE FEET: 500 OCCUPANTS: 4-8 FLOOR LOAD: BASE: CEILING HEIGHT: Per lobby 20 SPACE PROGRAM FOR ELK RIVER YMCA KID'S ZONE/CHILD CARE/yOUTH AREA I SPACE FUNCTION: . Check-in . Childwatch/Toddlcrs . Crib Space . Play Structure . Activity Spaces (3) . Storage . Offices (2) . Toilets SQUARE FEET: OCCUPANTS: 4,200 DIMENSIONS: TED Estimate 80 120 s,f. 600 "f. 120 "f. 1,000 d. 1,800 "f. 200 "f. 250 s,f. 120 s.f. (20+ occupan ts) (> I story tall) (3 @ 500 s.f.) (for teen eguipment/fumishing'), adjacent to Community Room SPECIAL CONSIDERATIONS: >1 story space fot climbing Structure, similar to Andover EQUIPMENT REQUIREMENTS: Sound system rough-in, including recess for speakers ACCESS/ ADJACENCY NEEDS: Community Room, Outdoors playground FLOOR FIN: Rubber sports floor if budget permits, Carpet, VCT FLOOR LOAD: WALL FIN: Painted R-\SE: CEILING FIN: Acoustical ceiling/ exposed structure CEILING HEIGHT: 10' ACOUSTICAL REQUIREMENTS: Needed ELECTRICAL POWER: LIGHTING: FOOT CANDLES: TELEPHONE: COMMUNICATION: SECURITY: CONTROLS: SOUND: HVAC: PLUMBING: OTHER: Origiuation Date: 2/06/07 Modification Date: 21