5.6. SR 08-22-1994
MS
CONSULTING ENGlNIJR!l
ovri ENGiNEERING:
ENV,IRON,I.1fNTAl
NIUt\,'JCiPAi
PIANN.ING
STRUCTURAi
. SU,~VEY.lNG
T.RAme
TRANSPORTATiON'
1326 Energy Pork Drive
St. Poul, MN 551 08
612-644-4389
Fox: 612-644-9446
.9800 Shelard Parkwoy
Minneopoli" MN 55441
612-546-0432
Fox: 612-544-6398
ITEM 5.6.
August 17, 1994
File; 230-215-30
PF-94-01A
Honorable Mayor and City Council
City of Elk River
13065 Orono Parkway
P.O. Box 490
Elk River, MN 55330
RE: NORTHEAST AREA UTILITIES
CHANGE ORDER NO.2
Dear Council Members:
As you are aware, the underground utility improvements in the Hillside Crossing
development are proposed to be accomplished by means of a change order to the existing
Arcon Construction project. Attached is a copy of the change order to accomplish this.
These prices have been previously reviewed by the Developer, Mr. Rick Foster, and he is
in agreement with this change order. Originally, it was thought that the public street
improvement on Evans A venue would also be part of the change order; however, we were
unable to reach a satisfactory price for this work. Therefore, the Developer, Mr. Foster,
will be contracting independently for the street improvements along with all of his necessary
private parking lot improvements.
We would recommend City Council approval of this change order contingent upon the
Developer meeting the necessary conditions for implementation of the construction. These
would primarily consist of signing a Developer's Agreement, filing the plat, and providing
the City with the necessary easements for the proposed improvements.
If you have any questions regarding this change order, I will be in attendance at your
August 22, 1994, City Council meeting.
Sincerely,
MSA, CONSULTING ENGINEERS
~jK~~
Terry J. Maurer, P.E.
TJM:tw
Enclosure
215-1707.aug
.
.
.
,08/18/84 08:16 tt612 678 2244 ARCON CONST. CO.
AUG-~&-'4 THU ':12 "SA aT ~AUL
1i!J002
"".Ild>.:.c
. CUI1GE 0ltDJ:1l.
( Instructions on revene .S.de) NO. Z
1'1l0Jzcr : Trunk S..ni~ and Water DATB or ISSW\NCI: August 22, 1594.
Elk l'ark Center
0WNEll. : City of Elk River
(Name, 130'~ Orono Parkway OWNER'. l'roject NO. 230-215-20
Jlddress) Elk }liver, HN 55330
CON'l'llACTOI\ : Arcon Constxucts.on ENGINE!;1\:
t.O. Bo.. !'I7 HSA, COnSUlting Bngineers
Mora, HN "on 1326 Ene~ Park Drive
5t. l'a\11, HN 'S10$
CONIRACT !'OR; Trunk Sanitary and. Yater
&lk Park c:.ntel: ENGDlEER's Pl:O~ec~ No. 230-2U-20
You are d1rect.ed to lU~e ~e foUowinlJ chang.... in the COnt~act Documants.
Description: See Ae.tached.
Purpose of ch....ge Order: See Ate.chad.
Attachmenu: IList doc~ents supporting chang-e) cost 8reakdown
CHANGE IN CONTRACT PIl:z:a, CHANGE :IN CON1'AACT TIME:
original contract :Price original CantL'act. TlJu
S 510,897.71 75
, UyI' 01' dac.
i're.V1ous Change OlOdelOs No. -L to No. ....-l.... Net change frC1ll previous Change Orders
S 13,368.15 0
..
Coneract. Price pl:ior to this Change Order contraCl: Time Prior t.o this change Order
S 524,266.46 .. 75
... ...
Net tncrease of this Change. Order Net Incr....e of this Change Ordel:'
S 241,670.49 21
....
contrac~ price with all approved. Change COntzact Time with all approved Chang"
Orders , O>:Clo:l,:S
S 765,936.95 "
....,.. ..GIlU
Rl!lCQMM&NI)&D: APP!l.Q\/BD: APP!l.Q\/BO:
By By BYe.\. . : f\ L . -
- Ilngineer OWner Cotitracl:or
EJCDC No. 1'10-8-8 11983 Ed1~lo.l
ELK PARK CENTER
. ARCON CONSTRUCTION, INC.
CHANGE ORDER NO.2
DESCRIPTION: This change order consists of the sanitary sewer, water, and SlOrm sewer
improvements in the Hillside Crossing plat.
PURPOSE OF THE
CHANGE ORDER: The purpose is 10 add the underground utilities in the Hillside Crossing plat 10 the
current project which brings these utilities 10 the site.
The estimated quantities and unit costs for this work are as follows:
SCHEDULE 1.0 SANITARY SEWER
np<;:l'"nprinn lInit F<t Qty TTnit Prit'P.: Fyfpn~inn
1. Connect 10 existing sanitary sewer EA 1.00 437.50 437.50
2. 8" PVC 10-12' deep LF 960.00 15.63 15,004.80
3. 8" PVC 12-14' deep LF 13.00 24.01 312.13
4. 8" PVC 14-16' deep LF 10.00 30.77 307.70
5. 6" PVC 10-12' deep LF 140.00 17.95 2,513.00
6. Standard manhole EA 5.00 1,450.00 7,250.00
7. Manhole extra depth LF 24.00 65.50 1,572.00
8. 8" x 6" wye EA 4.00 46.75 187.00
. 9. 8" PVC plug EA 1.00 38.75 38.75
10. Standard ProclOr EA 1.00 80.00 80.00
1 I. In-place Density EA 13.00 30.00 390.00
12. 12.8 outside drop EA 1.00 1,125.00 1.125.00
SCHEDULE 1 SANITARY SEWER TOTAL 29,217.88
SCHEDULE 2.0 W ATERMAIN
np:~('r;l?ri(m lInit F..t Qty Tlnit Prir:f' FytP:n~iC1n
1. Connect 10 existing 12" watermain EA 1.00 250.00 250.00
2. Connect 10 existing 10" watermain EA 1.00 250.00 250.00
3. 6" DIP LF 312.00 15.92 4,967.04
4. 8" DIP LF 991.50 15.61 15,477.31
5. 12" DIP LF 989.00 19.85 19,631.65
6. Hydrant w/valve EA 7.00 1,500.00 10,500.00
7. 6" Valve EA 3.00 322.50 %7.50
8. 8" Valve EA 3.00 437.50 1,312.50
9. Fittings LB 4,970.00 1.16 5,765.20
10. Standard ProclOr EA 1.00 80.00 80.00
11. In-place Density EA 19.00 30.00 570.00
SCHEDULE2 WATERMAIN TOTAL 7,297.50 59,771.20
.
CO#2-230.215
SCHEDULE 3.0 STORM SEWER
. OplIi::('riptinn lInit Pot Q1y Unit Pri('Jl'. Fyfp.n~inn
1. 12" RCP Class 5 LF , 438.00 20.00 8,760.00
2. 15" RCP Class 5 LF 204.50 21.30 4,355.85
3. 27" RCP Class 3 LF 180.00 31.82 5,727.60
4. 30" RCP Class 3 LF 1,260.00 38.35 48,321.00
5. 36" RCP Class 3 LF 48.50 56.66 2,748.01
6. 42" RCP Class 3 LF 106.00 62.58 6,633.48
7. 48" RCP Class 3 LF 407.00 75.21 30,610.47
8. 42" F.E.S. Class 3 EA 1.00 1,450.00 1,450.00
9. 48" RCP F.E.S. Class 3 EA 2.00 1,600.00 3,200.00
10. Catch basin 2' x 3' EA 4.00 900.00 3,600.00
11. 48" Manhole EA '4.00 1,187.50 4,750.00
12. 60" Manhole EA 13.00 2,060.00 26,780.00
13. 72" Manhole EA 1.00 4,615.00 4,615.00
14. In-place Density Test EA 35.00 30.00 1,050.00
15. Standard Proctor EA 1.00 80.00 80.00
SCHEDULE 4 STORM SEWER TOTAL $152,681.41
ESTIMATED TOTAL CHANGE ORDER NO.2 TOTAL $241,670.49
Tax and Bond included.
. Manhole, catch basin, and gate valve adjustments NOT included.
Ph" rock pipe bedding if needed - $9.00 ton.
.
CO'2-230.215
IN DEPEN DENT
CONSUL TING
. ENGINEERS, INC.
80 W. County Road C
Little Canada
St. Paul, Minnesota 55117
Suite 801
Bradford A_ Lemberg. P_E,. Pr.,idenl
PHONE: 612-482-9313
FAX: 612-482-9558
August 26, 1994
Mr. Jeff Gongoll, Chairman
Arena Task Force - Elk River
Riverside Development
241 Main Street
Elk River, MN 55330
Re: Proposal for professional Services
Project Coordination/Construction Management
And consulting and Design Services
Ice Skating Arena - Elk River, MN
File No. 230394
Dear Mr. Gongoll:
It was a pleasure meeting with you, the Arena Task Force and the
City staff on Monday, August 22, 1994 in regard to providing pro-
fessional services for this project.
.
We, at Independent Consulting Engineers, Inc. (I.C.E.) are happy
to submit this proposal for professional services to the Arena
Task Force of the city of Elk River for the proposed new ice
skating arena project.
I would like to emphasize the point that an indoor, refrigerated
ice skating rink is a unique facility that can be either a real
asset to a sports center or if not properly designed, with all
aspects carefully addressed, it can be a very costly disaster.
We, at Independent Consulting Engineers, Inc. (r.C.E.) are proud
of the facilities, of which we have been associated, both new
rinks and retrofit projects, and we are always cautious to make
sure that all items are carefully addressed so that we do not ex-
perience a failure or have a disgruntled client. While an ice
rink may, to the casual observer, look quite simple there are
several items that must be dealt with to avoid detrimental
affects on the other portions of the sports complex. By pro-
viding proper coordination, consulting, in addition to the rink
design, we at I.C.E. can be of benefit to the client and help in
developing a total facility in which all can feel comfortable and
take pride in the final outcome.
To avoid detrimental moisture problems throughout the center, if
it is to be used for surruner skating, it will be necessary to
design a dehumidification system that will control the atmosphere
within the facility. It will also be necessary to provide a pro-
perly designed ventilation system within the complex to avoid
.
.
.
.
Mr. Jeff Gongoll
- 2 -
August 26, 1994
unsafe conditions such as a buildup of carbon monoxide (CO) or
nitrogen dioxide (N02) levels that can be extremely detrimental
to the health and welfare of all participants or visitors in the
sports complex.
Factors such as properly designed dasher systems around the rinks
are essential. Proper disposal of the ice shavings must be
addressed. Quality of the ice must be of concern since poor ice
quality will drive away skaters and the' investment in a rink
system can be lost. Rink lighting at various levels will enhance
the quality of skating and also provide energy cost savings,
All of the mentioned items are extremely important to the invest-
ment in the sports center. They are mentioned to point out the
reason for engaging experienced ice rink consultants/designers to
assist in bringing the project to successful fruition.
Based on our understanding' of your needs and desires, as
discussed by phone and from our recent meeting, we are submitting
our proposal broken into phases to cover the full scope of the
project from planning through construction and facility start-up.
In this way it is felt that we can best serve your needs and work
wi th you to reali ze the most economically feasible ice skating
facili ty.
It is important that good, qualified and caring architects and
engineers be a part of the total team. We will, therefore, assist
in providing a listing of those well qualified for a project such
as yours and will also assist in the final selections. It is
anticipated that the architect selected would include the neces-
sary mechanical, electrical, structural and civil engineers as a
part of their contract with your group.
The role of I.C.E. in your project is outlined in the following
pages under the heading - Proposal 'A'. This covers the proposed
phasing and services to be incorporated into our contract with
you. It is our feeling that our contract should be separate from
that of the architect and the construction contractors to better
serve your interests and needs and be able to remain totally un-
biased in our services.
I.C.E. is not, in any way, tied to any of the equipment manufac-
turers/ installers and can, therefore, provide totally unbiased
review and recommendations on all of the manufacturers' products
and installations.
.
Mr. Jeff Gongoll
- 3 -
August 26, 1994
LC.E. also feels that it is extremely important to properly
assure a good installation by being present at the time of the
installation of the ice floor and appurtenances and to provide
regular construction observation to avoid any future problems
caused by improper or poorly installed systems,
We are prepared to start immediately onthe project.
LC.E. carries complete errors and omissions and all liability
coverage for our services and will submit copies of our coverage
if so requested.
As previously stated, I,C.E. is very happy to submit this propo-
sal and we look forward to working wi th you on a very good
project. ----
.
If there are any questions on our submittal, please contact our
office.
Upon approval of our proposal, as stated, it is assumed that we
will prepare a Client (Owner)/Consultant Contract between the
City Task Force (City of Elk River) and I.C.E. using the standard
forms for all items desired.
Respectfully submitted,
BAL:sjp
Attached: proposal 'A'
Exhibit A
.
.
.
.
PROPOSAL 'A'
For Professional Services to provide Modified
PROJECT COORDINATION/CONSTRUCTION MANAGEMENT
& CONSULTING & DESIGN SERVICES
For the Proposed
Ice Skating Arena
Elk River, Minnesota
Independent Consulting Engineers, Inc., hereinafter referred to as
I.C.E., hereby submits the following proposal for professional services
for the Elk River Ice Skating Arena Development Program.
This proposal provides a phased, modified service proposal including
project Coordination/Construction Management and Consulting and Partial
Design Services for the project as outlined and described herein for
reimbursement fees as shown at the end of this proposal.
The I.C.E. services to be provided are as follows:
Phase I - proiect Planning and Development
A. Assist Task Force in planning and scope of project.
B. Assist Task Force and Bonding Consultant in determination of
financial needs.
C. Assist Task Force in setting up possible sub-committees:
1. Finance/Fund Raising
2. Building Planning
3. Management
4. promotion/publicity
D. Assist Task Force in Architect/Engineer (A/E) selection.
E. Assist Task Force in project Schedule preparation.
.
.
.
proposal 'A' - continued
Page 2.
phase II - Schematic Desiqn
A. Coordinate between Task Force and A/E on the preparation of
preliminary plan layouts and facility concept.
B. Coordinate with A/E on preliminary Opinions of probable
Costs
C. Coordinate obtaining necessary soil borings. (Billed
directly to City.)
Phase III - Desiqn Development
A.
Coordinate between Task Force and A/E on development plans,
preliminary specifications, materials selections, etc.
B.
Refrigeration System and Rink Floor
1. pre-design (Design Development phase) meeting with
Architects/Engineers and, the Task Force Representatives.
2. Assistance in the ice rink and related facility layouts
during design development.
3. Review of soil borings and subsoil analysis related to
ice sheet.
C. Coordinate with A/E on Opinions of probable Costs.
D. Conduct preliminary value engineering study on the design
development.
Phase IV - Construction Documents
A. Coordinate between Task Force and A/E for review of final
design and development of detailed bid documents including
plans and specifications.
B. Conduct periodic meetings with A/E to coordinate final plan
and specification development.
C. Ice related design including plans and specifications.
.
proposal 'A' - Continued
Page 3.
.
1. Refrigeration system
2. Ice floor and refrigeration piping
3. Underslab heating system for frost depth control uti-
lizing waste heat from the refrigeration system.
4. Snowmelt pit
5. Ice perimeter dasherboards
6. Dehumidification system consultation with AlE
7. Consulting assistance in lighting system and sound
system design with AlE
8. Consulting assistance in arena ventilation system design
with AlE
9. Consulting assistance on total facility layout for
providing the necessary efficiency in management with
AlE and Task Force Committee
10. Consulting assistance on materials and finishes for
critical areas and for guidance on dressing room
accessories, etc.
11. Ice resurfacer and necessary accessories recommendations
to Task Force Committee
12. Miscellaneous consulting to assist in sports center
design
Phase V - Bidding and Construction Contracts
A.
B.
C.
D.
E.
.
Meet with local building inspectors for project approvals.
Contact all qualified contractors.
Hold pre-bid meeting in Elk River for contractors infor-
mation and questions.
Review all bids and make recommendations for contract awards.
Oversee preparation of contracts for construction.
.
.
.
proposal 'A' - continued
Page 4.
Phase VI - Construction
A. Hold pre-construction meeting wi th city staff, Task Force
building committee, AlE and contractors.
B. Set project construction schedule.
C. Hold regularily scheduled project coordination meetings
either weekly or bi-weekly with contractors, etc.
D. Review all contractors payment requests.
E. Provide periodic construction observation of entire project
and coordinate construction observation with city and AlE
and coordinate shop drawing review.
F. personally provide full time observation of rink floor
concrete pour after checking all piping and reinforcing,
etc.
G.
Coordinate final project inspection.
H. Coordinate facility equipment startup and training for rink
management staff.
All fees for I.C.E. covering the above project outline services to be
on hourly basis as shown on the attached Exhibit 'A' for an amount "not
to exceed" $50,000 plus reimbursables as listed.
It is anticipated that the fees, by project phase, will be approxima-
tely as follows:
Phase % of Fee Estimated Fee
Phase I 3% $ 1,500
phase II 16% 8,000
phase III 24% 12,000
phase IV 40% 20,000
phase V 8% 4,000
Phase VI 9% 4,500
Total project 100% $ 50,000
INDEPENDENT
CONSUL TING
. ENGINEERS, INC.
80 W County Road C
Little Canada
St. Paul, Minnesola 55117
Suite 801
Bradford A. Lemberg, PE" p,.;ident
PHONE: 612-482-9313
FAX: 612-482-9558
EXHIBIT A
SCHEDULE OF HOURLY RATES & REIMBURSABLE CHARGES
Effective January 1, 1994
principal
$80.00/hour
Engineer, Registered
65.00/hour
70.00/hour
45.00/hour
35.00/hour
30.00/hour
Architect, Registered
Senior Technician
Technician/Drafter'
Wordprocessor/Clerical
.
The following items are considered to be direct reimbursables,
outside of the basic services covered by our hourly' rates.
Item
Billinq Rate
Messenger Service Delivery
1.0 x Invoice Amount
UPS, FedEX, etc.
1.0 x Invoice Amount
printing, Including Xerox,
blueprints, etc.
1.0 x Invoice Amount
Travel by Company Vehicle
0.28/mile
1.0 x Invoice Amount
1.0 x Invoice Amount
1.0 x Invoice Amount
1.0 x Invoice Amount
1.0 x Invoice Amount
Automobile Rental
Airline travel
Lodging
Meals (excluding noon lunch)
Soil borings
.
All billable items including fees, hourly rates and reimbursables
are based on percentage or portion of work completed. All invoices
are due upon receipt. Interest at the rate of 18% per annum will
be charged on invoices are 30 days or more past due unless other
terms are arranged prior to starting work.